# MEAN WELL HRP-300N3 datasheet

Source: https://www.meanwell.com/Upload/PDF/HRP-300N3/HRP-300N3-SPEC.PDF
PDF: https://eloragrid.ai/equipment-documents/f9c461538a28163c10327dda95445f3553ff06d1e9cf1131ca3a8abc65d2eca3.pdf
Revision: 2026-04-03
Pages: 6

- Specification: page 2
- Mechanical specification: page 6
- Block diagram: page 3
- Derating curve: page 2
- Installation: page 6
- Safety warnings: page 2

## HRP-300N3-12
Equipment: https://eloragrid.ai/equipment-library/equipment/mean-well-hrp-300n3-12
- Dc Voltage: 12V (page 2)
- Rated Current: 27A (page 2)
- Rated Power: 324W (page 2)
## HRP-300N3-24
Equipment: https://eloragrid.ai/equipment-library/equipment/mean-well-hrp-300n3-24
- Dc Voltage: 24V (page 2)
- Rated Current: 14A (page 2)
- Rated Power: 336W (page 2)
## HRP-300N3-36
Equipment: https://eloragrid.ai/equipment-library/equipment/mean-well-hrp-300n3-36
- Dc Voltage: 36V (page 2)
- Rated Current: 9A (page 2)
- Rated Power: 324W (page 2)
## HRP-300N3-48
Equipment: https://eloragrid.ai/equipment-library/equipment/mean-well-hrp-300n3-48
- Dc Voltage: 48V (page 2)
- Rated Current: 7A (page 2)
- Rated Power: 336W (page 2)