{"id":"mean-well-hrpg-1000n3-datasheet","kind":"datasheet","title":"MEAN WELL HRPG-1000N3 datasheet","manufacturer":"MEAN WELL","sourceUrl":"https://www.meanwell.com/Upload/PDF/HRPG-1000N3/HRPG-1000N3-SPEC.PDF","sha256":"6097e9d6ff855a14dd335079dcb6808b1083919fab74b5408ed3f2a127d54769","bytes":864281,"pageCount":7,"revision":"2026-04-03","retrievedAt":"2026-11-24T00:00:00.000Z","filePath":"/equipment-documents/6097e9d6ff855a14dd335079dcb6808b1083919fab74b5408ed3f2a127d54769.pdf","language":"en","equipmentIds":["mean-well-hrpg-1000n3-12","mean-well-hrpg-1000n3-24","mean-well-hrpg-1000n3-36","mean-well-hrpg-1000n3-48"],"variants":[{"equipmentId":"mean-well-hrpg-1000n3-12","model":"HRPG-1000N3-12","facts":[{"label":"Dc Voltage","value":"12V","page":2},{"label":"Rated Current","value":"80A","page":2},{"label":"Rated Power","value":"960W","page":2}],"page":2},{"equipmentId":"mean-well-hrpg-1000n3-24","model":"HRPG-1000N3-24","facts":[{"label":"Dc Voltage","value":"24V","page":2},{"label":"Rated Current","value":"42A","page":2},{"label":"Rated Power","value":"1008W","page":2}],"page":2},{"equipmentId":"mean-well-hrpg-1000n3-36","model":"HRPG-1000N3-36","facts":[{"label":"Dc Voltage","value":"36V","page":2},{"label":"Rated Current","value":"28A","page":2},{"label":"Rated Power","value":"1008W","page":2}],"page":2},{"equipmentId":"mean-well-hrpg-1000n3-48","model":"HRPG-1000N3-48","facts":[{"label":"Dc Voltage","value":"48V","page":2},{"label":"Rated Current","value":"21A","page":2},{"label":"Rated Power","value":"1008W","page":2}],"page":2}],"sections":[{"title":"Specification","page":2},{"title":"Mechanical specification","page":7},{"title":"Block diagram","page":3},{"title":"Derating curve","page":2},{"title":"Installation","page":7},{"title":"Safety warnings","page":2}]}