# MEAN WELL UHP-750 datasheet

Source: https://www.meanwell.com/Upload/PDF/UHP-750/UHP-750-SPEC.PDF
PDF: https://eloragrid.ai/equipment-documents/dd0ed2d23cfb94fc088086f4d8886c98fae41eaa0b32691fa21749c4a6a14531.pdf
Revision: 2025-08-01
Pages: 5

- Specification: page 2
- Mechanical specification: page 4
- Block diagram: page 3
- Derating curve: page 2
- Installation: page 5
- Safety warnings: page 1

## UHP-750-12
Equipment: https://eloragrid.ai/equipment-library/equipment/mean-well-uhp-750-12
- Dc Voltage: 12V (page 2)
- Rated Current: 60A (page 2)
- Rated Power: 720W (page 2)
## UHP-750-24
Equipment: https://eloragrid.ai/equipment-library/equipment/mean-well-uhp-750-24
- Dc Voltage: 24V (page 2)
- Rated Current: 31.3A (page 2)
- Rated Power: 751.2W (page 2)
## UHP-750-36
Equipment: https://eloragrid.ai/equipment-library/equipment/mean-well-uhp-750-36
- Dc Voltage: 36V (page 2)
- Rated Current: 20.9A (page 2)
- Rated Power: 752.4W (page 2)
## UHP-750-48
Equipment: https://eloragrid.ai/equipment-library/equipment/mean-well-uhp-750-48
- Dc Voltage: 48V (page 2)
- Rated Current: 15.7A (page 2)
- Rated Power: 753.6W (page 2)