{"schemaVersion":1,"slug":"50-instantaneous-overcurrent","name":"Instantaneous overcurrent","kind":"function","abbreviation":"50","aliases":["instantaneous OC","50P","50N","50G","instantaneous over current"],"category":"measurement-protection","drawingTypes":["SLD","Schematic"],"referenceFamilies":["IEEE / ANSI"],"summary":"An overcurrent function without an intentional operating time delay in its instantaneous application.","description":["An instantaneous overcurrent function detects current above its operating criteria without an intentional time delay in the instantaneous application. Actual operating time, implementation and any combined 50/51 labelling are documented by the manufacturer.","On a power drawing, keep this function reference connected to the selected equipment and its complete designation. A multifunction relay can implement several numbered functions. This entry explains the reference; it supplies no settings or commissioning procedure."],"readingNotes":["Identify phase, residual or another measurement from the full designation.","Separate the function reference from pickup and other settings."],"drawingChecklist":["Reference CT or other current inputs.","Identify the protected circuit and relay.","Link the associated trip logic."],"distinction":"Instantaneous does not mean zero physical operating time. A 50 label does not supply pickup values or prove coordination with other protection.","facts":[{"label":"ANSI / IEEE function number","value":"50"},{"label":"Equipment implementation","value":"Consult the selected device manual"},{"label":"Suffix interpretation","value":"Application and manufacturer documentation"}],"references":[{"sourceId":"device-numbers","relevance":"Public manufacturer table used to check the base function-number name."},{"sourceId":"ieee-functions","relevance":"Normative publication reference for the device-function convention."},{"sourceId":"abb-functions","relevance":"Public examples of manufacturer-specific function names and suffixes."}],"related":["51-time-overcurrent","current-transformer","52-ac-circuit-breaker"],"artwork":"function","publishedOn":"2026-10-13","updatedOn":"2026-10-13","provenance":"independent-public-research","url":"https://eloragrid.ai/protection-functions/50-instantaneous-overcurrent","illustration":{"url":"https://eloragrid.ai/library/illustrations/50-instantaneous-overcurrent.svg","scope":"Original educational concept; not an official standard graphic or product footprint","license":"https://creativecommons.org/licenses/by/4.0/"},"sources":[{"id":"device-numbers","title":"Public reference table of ANSI device-function numbers","publisher":"Schneider Electric","url":"https://www.se.com/es/es/faqs/FA34639/","type":"manufacturer","scope":"Spanish-language public reference table. Used to check device-number names; no claim that every function is implemented in every device.","checkedOn":"2026-10-13","reuse":"link-only","relevance":"Public manufacturer table used to check the base function-number name."},{"id":"ieee-functions","title":"IEEE C37.2-2022: power-system device function numbers","publisher":"IEEE","url":"https://ieeexplore.ieee.org/document/9984140","type":"standard","scope":"Device function numbers, acronyms and contact designations. The full publication may require access through IEEE.","checkedOn":"2026-10-13","reuse":"link-only","relevance":"Normative publication reference for the device-function convention."},{"id":"abb-functions","title":"Relion 620: functions, codes and symbols","publisher":"ABB","url":"https://techdoc.relays.protection-control.abb/r/620-series-IEC-60870-5-103-Point-List-Manual/2.0-FP1-IEC/en-US/Functions-codes-and-symbols","type":"manufacturer","scope":"Published product mappings between function names, IEC 61850 identifiers, IEC mnemonics and ANSI designations. These are product examples, not universal equivalences.","checkedOn":"2026-10-13","reuse":"link-only","relevance":"Public examples of manufacturer-specific function names and suffixes."}]}