{"id":"abb-3-4-pole-low-voltage-mccb-t2-fixed-version-din-rail-assembly-1e7585556f","name":"3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly","manufacturer":"ABB","category":"breakers","description":"ABB 3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly: breaker or breaker-accessory reference for breaker compartment and mounting interfaces. Manufacturer reference ITSCE-RH0012128.","equipment":["3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly"],"keywords":["3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly","","ITSCE-RH0012128","Switchgear and switchboards","breaker","breaker compartment and mounting interfaces","breaker or breaker-accessory reference"],"markets":["Global"],"marketNote":"Confirm the exact regional configuration against the selected manufacturer drawing.","kind":"drawing","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-RH0012128&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E","officialEvidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-RH0012128&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E","sourcePublisher":"ABB","formats":["DXF"],"availability":"direct","accessNote":"1 original file is available to download here. Manufacturer sources and revisions are listed below.","checkedAt":"2026-11-04","files":[{"id":"73069bb559c582d0de6a","name":"ITSCE_RH0012128.dxf","format":"DXF","purpose":"Manufacturer drawing reference ITSCE-RH0012128","url":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-RH0012128&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E","availability":"direct","sha256":"73069bb559c582d0de6a40aff702a3431545bf1e2f25ccd200de29ac8dc9572d","bytes":268603,"retrievedAt":"2026-11-04T00:58:03Z","filenameBasis":"response-header","revision":"E","hosted":true,"redistribution":"unknown","validation":"signature-checked","documentNumber":"ITSCE-RH0012128","latestRevisionUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-RH0012128&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch","rightsReview":{"checkedAt":"2026-11-04","sources":["https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-RH0012128&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E"],"note":"Reviewed the available source, embedded drawing text and archive notices. No explicit applicable redistribution prohibition was identified. Rights remain unknown; no licence or manufacturer endorsement is asserted."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-04","evidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-RH0012128&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E","attribution":"ABB"},"delivery":{"kind":"original","name":"ITSCE_RH0012128.dxf","format":"DXF","sha256":"73069bb559c582d0de6a40aff702a3431545bf1e2f25ccd200de29ac8dc9572d","bytes":268603,"includes":["ITSCE_RH0012128.dxf"]},"downloadUrl":"https://eloragrid.ai/tools/cad-library/download/abb-3-4-pole-low-voltage-mccb-t2-fixed-version-din-rail-assembly-1e7585556f/73069bb559c582d0de6a"}],"fileClasses":["manufacturer DXF file"],"configurationNote":"The supplied configuration is “3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly”. Keep those frame, mounting and accessory codes with the inserted drawing.","technicalFacts":[{"label":"Manufacturer reference","value":"ITSCE-RH0012128","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-RH0012128&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E"},{"label":"Document revision","value":"E","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-RH0012128&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E"}],"drawingNumber":"ITSCE-RH0012128","equipmentFacts":[{"label":"Equipment / resource","value":"3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly"},{"label":"Manufacturer","value":"ABB"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Manufacturer drawing","value":"ITSCE-RH0012128"},{"label":"Manufacturer reference","value":"ITSCE-RH0012128"},{"label":"Document revision","value":"E"},{"label":"Listed file formats","value":"DXF"},{"label":"Listed files","value":"1"},{"label":"Available previews","value":"1 drawing previews"},{"label":"Recorded revisions","value":"E"},{"label":"Source checked","value":"2026-11-04"},{"label":"Download access","value":"Email registration for site downloads; official source links are also available"}],"previewImage":"/tools/cad-library/drawing-preview/abb-3-4-pole-low-voltage-mccb-t2-fixed-version-din-rail-assembly-1e7585556f/73069bb559c582d0de6a?asset=73069bb559c582d0de6a40aff702a3431545bf1e2f25ccd200de29ac8dc9572d","relatedReferences":[{"name":"Air circuit breaker","url":"https://eloragrid.ai/objects/ga-air-circuit-breaker"},{"name":"Moulded-case circuit breaker","url":"https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker"}],"fileChoiceGuidance":["Use ITSCE_RH0012128.dxf revision E for editable DXF drawing geometry. Keep its original layers and dimension annotations when inserting the drawing."],"plainEnglish":{"title":"Using the 3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly reference","introduction":"ABB 3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly: breaker or breaker-accessory reference for breaker compartment and mounting interfaces. Manufacturer reference ITSCE-RH0012128.","example":"Use ITSCE_RH0012128.dxf revision E for editable DXF drawing geometry. Keep its original layers and dimension annotations when inserting the drawing.","drawings":"Use ITSCE_RH0012128.dxf revision E for editable DXF drawing geometry. Keep its original layers and dimension annotations when inserting the drawing.","terms":[],"diagram":"flow","steps":["Identify 3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly","Select the drawing or model","Check the mounting interface"],"caption":"The supplied configuration is “3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly”. Keep those frame, mounting and accessory codes with the inserted drawing.","sources":[{"label":"ABB source","url":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-RH0012128&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E"}],"questions":[{"question":"What can I use the 3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly reference for?","answer":"Use this breaker or breaker-accessory reference for breaker compartment and mounting interfaces. The supplied configuration is “3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly”. Keep those frame, mounting and accessory codes with the inserted drawing."},{"question":"Which manufacturer reference identifies this drawing?","answer":"ABB reference ITSCE-RH0012128. The file list retains the original source and recorded revision."}],"checklist":["The supplied configuration is “3-4 Pole low voltage MCCB -T2 - Fixed version - DIN rail assembly”. Keep those frame, mounting and accessory codes with the inserted drawing.","Use the exact frame, pole and mounting configuration named by this reference. Door drilling, connection and accessory drawings describe those interfaces rather than a complete switchboard."]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/abb-3-4-pole-low-voltage-mccb-t2-fixed-version-din-rail-assembly-1e7585556f"}