# 3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4

3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4: ABB manufacturer DXF resource, document ITSCE-601812571, revision E. Use it to coordinate the breaker, switch or accessory arrangement in the switchgear assembly.

## Equipment and file summary

Equipment / resource: 3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4
Manufacturer: ABB
Resource type: Named drawing reference
Manufacturer drawing: ITSCE-601812571
Listed file formats: DXF
Listed files: 1
Available previews: 1 drawing previews
Recorded revisions: E
Source checked: 2026-11-03
Download access: Email registration for site downloads; official source links are also available

## Related GA references

- [Air circuit breaker](https://eloragrid.ai/objects/ga-air-circuit-breaker)
- [Moulded-case circuit breaker](https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/abb-3pole-low-voltage-mccb-series-isomax-withdrawable-version-cable-terminals-s4-4557ef1a
Manufacturer: ABB
Entry type: Named drawing reference
Part number: Not specified — select exact configuration
Category: Breakers & accessories
Formats: DXF
Market discovery: Global
Access: Direct download
Official source: https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601812571&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch
Manufacturer evidence: https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601812571&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E
Source checked: 2026-11-03

Download the verified original here. The manufacturer source is linked for revision checks; preview images are for inspection and the original drawing supplies the design dimensions.
Manufacturer library discovery does not establish regional certification. Match the listed frame, terminal arrangement and accessories to the project.
Original DXF drawing for 3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4; ABB document ITSCE-601812571


## In plain English

### What the equipment does

A circuit breaker opens and closes a power circuit and can interrupt it when its protection or trip system responds to a fault.

### A simple example

When coordinating 3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4 in switchgear, place the documented arrangement beside the adjacent equipment and compare its fixing and connection access with the source drawing.

### What the drawings help you do

Use ITSCE_601812571.dxf for 3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4. DXF is the supplied drawing format; the preview shows the source sheet. A matching STEP model is not included. Match ABB document ITSCE-601812571 revision E when checking a replacement.

### Before using this reference

- Match the configuration named “3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4”; terminal direction, mounting version and pole options can change the outline.
- Use ABB document ITSCE-601812571, revision E, to check the mounting and connection details before placing this item in the assembly.
- This is the withdrawable arrangement named in the source. Coordinate the cradle and the space needed to withdraw the device; the model envelope does not include that movement.
- Read the actual dimensions and notes in ITSCE_601812571.dxf; a 2D outline does not provide a complete 3D assembly.

### Which ABB source identifies 3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4?

The acquired file is ITSCE_601812571.dxf, document ITSCE-601812571, revision E. The manufacturer source and pinned original link appear below.

### Does the preview establish installation clearances?

No. Use the installation requirements for 3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4 and the selected assembly to reserve cable and service access.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Identify the named configuration → Check the manufacturer drawing → Coordinate mounting and connections
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [ABB official source](https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601812571&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E)


## Which file should I choose?

Use ITSCE_601812571.dxf for 3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4. DXF is the supplied drawing format; the preview shows the source sheet. A matching STEP model is not included. Match ABB document ITSCE-601812571 revision E when checking a replacement.

## Official files

- ITSCE_601812571.dxf (DXF): https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601812571&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E
  Site download: https://eloragrid.ai/tools/cad-library/download/abb-3pole-low-voltage-mccb-series-isomax-withdrawable-version-cable-terminals-s4-4557ef1a/original
  Hosting basis: no-explicit-prohibition; publisher attribution: ABB; reviewed: 2026-11-03
  Rights review: Public ABB Library metadata, original file header and extracted document notices were inspected. No explicit prohibition was identified in this specific original or the library terms link. Copyright remains with ABB; no redistribution licence is asserted.; evidence: https://library.abb.com/, https://library.abb.com/privacy, https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601812571&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E
  Purpose: Original DXF drawing for 3Pole low voltage MCCB series Isomax - Withdrawable version cable terminals S4; ABB document ITSCE-601812571; acquired: true; redistribution: unknown; SHA-256: ec7149644dd89ed23e2113b4e36cd418dec030f66e21a2afbbe25df6f9f66041; revision: E

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.