{"id":"abb-e1-2-e1-3-iv-w-terminals-es-lower-ul-a283a59c02","name":"E1.2/E1.3 IV W TERMINALS ES LOWER - UL","manufacturer":"ABB","category":"breakers","description":"ABB E1.2/E1.3 IV W TERMINALS ES LOWER - UL: breaker connection or accessory reference for breaker compartment and mounting interfaces. Manufacturer reference 1SDH001336R0073.","equipment":["E1.2/E1.3 IV W TERMINALS ES LOWER - UL"],"keywords":["E1.2/E1.3 IV W TERMINALS ES LOWER - UL","","1SDH001336R0073","Connections, wiring and earthing","breaker","breaker compartment and mounting interfaces","breaker connection or accessory reference"],"markets":["Global"],"marketNote":"Confirm the exact regional configuration against the selected manufacturer drawing.","kind":"drawing","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001336R0073&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","officialEvidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001336R0073&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","sourcePublisher":"ABB","formats":["STEP"],"availability":"direct","accessNote":"1 original file is available to download here. Manufacturer sources and revisions are listed below.","checkedAt":"2026-11-03","files":[{"id":"0f70194e78687e58fc5f","name":"1SDH001336R0073_1PA_001_00_E1.2_IV_W_TERMINALS_ES_LOWER_UL.stp","format":"STEP","purpose":"Manufacturer drawing reference 1SDH001336R0073","url":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001336R0073&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","availability":"direct","sha256":"0f70194e78687e58fc5f41ea24e7e58bbf725a4bcfd6a3dcd6436ab23d8d7c98","bytes":1352100,"retrievedAt":"2026-11-03T01:55:37.866687Z","filenameBasis":"response-header","revision":"A","hosted":true,"redistribution":"unknown","validation":"signature-checked","documentNumber":"1SDH001336R0073","latestRevisionUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001336R0073&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch","rightsReview":{"checkedAt":"2026-11-04","sources":["https://search.abb.com/library/Download.aspx?DocumentID=1SDH001336R0073&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"],"note":"Reviewed the available source, embedded drawing text and archive notices. No explicit applicable redistribution prohibition was identified. Rights remain unknown; no licence or manufacturer endorsement is asserted."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-04","evidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001336R0073&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","attribution":"ABB"},"delivery":{"kind":"original","name":"1SDH001336R0073_1PA_001_00_E1.2_IV_W_TERMINALS_ES_LOWER_UL.stp","format":"STEP","sha256":"0f70194e78687e58fc5f41ea24e7e58bbf725a4bcfd6a3dcd6436ab23d8d7c98","bytes":1352100,"includes":["1SDH001336R0073_1PA_001_00_E1.2_IV_W_TERMINALS_ES_LOWER_UL.stp"]},"downloadUrl":"https://eloragrid.ai/tools/cad-library/download/abb-e1-2-e1-3-iv-w-terminals-es-lower-ul-a283a59c02/0f70194e78687e58fc5f"}],"fileClasses":["manufacturer STEP file"],"configurationNote":"This reference covers the connection or accessory named in “E1.2/E1.3 IV W TERMINALS ES LOWER - UL”. It is not the complete breaker-and-compartment assembly. The supplied configuration is “E1.2/E1.3 IV W TERMINALS ES LOWER - UL”. Keep those frame, mounting and accessory codes with the inserted drawing.","technicalFacts":[{"label":"Manufacturer reference","value":"1SDH001336R0073","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001336R0073&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Document revision","value":"A","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001336R0073&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Model envelope: 1SDH001336R0073_1PA_001_00_E1.2_IV_W_TERMINALS_ES_LOWER_UL.stp","value":"430 × 104.6 × 290 mm (approximate X × Y × Z bounds of the tessellated source model)","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001336R0073&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"}],"drawingNumber":"1SDH001336R0073","equipmentFacts":[{"label":"Equipment / resource","value":"E1.2/E1.3 IV W TERMINALS ES LOWER - UL"},{"label":"Manufacturer","value":"ABB"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Manufacturer drawing","value":"1SDH001336R0073"},{"label":"Manufacturer reference","value":"1SDH001336R0073"},{"label":"Document revision","value":"A"},{"label":"Model envelope: 1SDH001336R0073_1PA_001_00_E1.2_IV_W_TERMINALS_ES_LOWER_UL.stp","value":"430 × 104.6 × 290 mm (approximate X × Y × Z bounds of the tessellated source model)"},{"label":"Listed file formats","value":"STEP"},{"label":"Listed files","value":"1"},{"label":"Available previews","value":"1 interactive model variants"},{"label":"Recorded revisions","value":"A"},{"label":"Source checked","value":"2026-11-03"},{"label":"Download access","value":"Email registration for site downloads; official source links are also available"}],"previewImage":"/tools/cad-library/preview/abb-e1-2-e1-3-iv-w-terminals-es-lower-ul-a283a59c02/0f70194e78687e58fc5f?asset=0f70194e78687e58fc5f41ea24e7e58bbf725a4bcfd6a3dcd6436ab23d8d7c98&view=thumb&v=62ded3a88ef75a17","relatedReferences":[{"name":"Air circuit breaker","url":"https://eloragrid.ai/objects/ga-air-circuit-breaker"},{"name":"Moulded-case circuit breaker","url":"https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker"}],"fileChoiceGuidance":["Use 1SDH001336R0073_1PA_001_00_E1.2_IV_W_TERMINALS_ES_LOWER_UL.stp revision A for the supplied solid assembly in your 3D layout."],"plainEnglish":{"title":"Using the E1.2/E1.3 IV W TERMINALS ES LOWER - UL reference","introduction":"ABB E1.2/E1.3 IV W TERMINALS ES LOWER - UL: breaker connection or accessory reference for breaker compartment and mounting interfaces. Manufacturer reference 1SDH001336R0073.","example":"Use 1SDH001336R0073_1PA_001_00_E1.2_IV_W_TERMINALS_ES_LOWER_UL.stp revision A for the supplied solid assembly in your 3D layout. Match the E1.2/E1.3 IV W TERMINALS ES LOWER - UL configuration named by ABB.","drawings":"Use 1SDH001336R0073_1PA_001_00_E1.2_IV_W_TERMINALS_ES_LOWER_UL.stp revision A for the supplied solid assembly in your 3D layout.","terms":[],"diagram":"flow","steps":["Identify E1.2/E1.3 IV W TERMINALS ES LOWER - UL","Select the drawing or model","Check the mounting interface"],"caption":"This reference covers the connection or accessory named in “E1.2/E1.3 IV W TERMINALS ES LOWER - UL”. It is not the complete breaker-and-compartment assembly. The supplied configuration is “E1.2/E1.3 IV W TERMINALS ES LOWER - UL”. Keep those frame, mounting and accessory codes with the inserted drawing.","sources":[{"label":"ABB source","url":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001336R0073&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"}],"questions":[{"question":"What can I use the E1.2/E1.3 IV W TERMINALS ES LOWER - UL reference for?","answer":"Use this breaker connection or accessory reference for breaker compartment and mounting interfaces. This reference covers the connection or accessory named in “E1.2/E1.3 IV W TERMINALS ES LOWER - UL”. It is not the complete breaker-and-compartment assembly."},{"question":"Which manufacturer reference identifies this drawing?","answer":"ABB reference 1SDH001336R0073. The file list retains the original source and recorded revision."}],"checklist":["This reference covers the connection or accessory named in “E1.2/E1.3 IV W TERMINALS ES LOWER - UL”. It is not the complete breaker-and-compartment assembly.","The supplied configuration is “E1.2/E1.3 IV W TERMINALS ES LOWER - UL”. Keep those frame, mounting and accessory codes with the inserted drawing.","Use the exact frame, pole and mounting configuration named by this reference. Door drilling, connection and accessory drawings describe those interfaces rather than a complete switchboard.","1SDH001336R0073_1PA_001_00_E1.2_IV_W_TERMINALS_ES_LOWER_UL.stp has approximate model bounds of 430 × 104.6 × 290 mm (approximate X × Y × Z bounds of the tessellated source model). Compare these model axes with the installation orientation; mounting and service clearances are separate requirements."]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/abb-e1-2-e1-3-iv-w-terminals-es-lower-ul-a283a59c02"}