# ReliaMod Outline Drawing, Main Fusible Switch Module, RMM3F4R

ABB ReliaMod Outline Drawing, Main Fusible Switch Module, RMM3F4R: switchboard or switchgear reference for panel arrangement and interfaces to adjacent equipment. Manufacturer reference 1TQC1333E0054.

## Equipment and file summary

Equipment / resource: ReliaMod Outline Drawing, Main Fusible Switch Module, RMM3F4R
Manufacturer: ABB
Resource type: Named drawing reference
Manufacturer drawing: 1TQC1333E0054
Manufacturer reference: 1TQC1333E0054
Document revision: B
Amperage: 400A CLASS T FUSE PROVISIONS.
SCCR: 100kA with Fuse Installed (Class T) SWITCH 2.19
Phase: 3-Phase 4-Wire
Voltage: 208Y/120V
Amperage: 400A
Switch Frame: XT5S
SCCR: 100kA with Fuse Installed (Class T)
Incoming Feed: Bottom/Top
Enclosure: N3R Outdoor
Estimated Weight: 160 lbs
Drawing units (1TQC1333E0054.pdf, page 1): inches
Drawing views (1TQC1333E0054.pdf, page 1): bottom view, front view, side view, top view
Listed file formats: PDF
Listed files: 1
Available previews: 1 drawing previews
Recorded revisions: B
Source checked: 2026-11-04
Download access: Email registration for site downloads; official source links are also available

## Related GA references

- [Switchgear panel](https://eloragrid.ai/objects/switchgear-panel)
- [Switchboard](https://eloragrid.ai/objects/switchboard)
- [Ring main unit](https://eloragrid.ai/objects/ring-main-unit)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/abb-reliamod-outline-drawing-main-fusible-switch-module-rmm3f4r-ff7ac12800
Manufacturer: ABB
Entry type: Named drawing reference
Part number: Not specified — select exact configuration
Category: Switchboards & switchgear
Formats: PDF
Market discovery: Global
Access: Direct download
Official source: https://search.abb.com/library/Download.aspx?DocumentID=1TQC1333E0054&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=B
Manufacturer evidence: https://search.abb.com/library/Download.aspx?DocumentID=1TQC1333E0054&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=B
Source checked: 2026-11-04

1 original file is available to download here. Manufacturer sources and revisions are listed below.
Confirm the exact regional configuration against the selected manufacturer drawing.
1TQC1333E0054.pdf, page 1, includes bottom view, front view, side view, top view. Select the view matching your GA orientation. The unit note on 1TQC1333E0054.pdf, page 1, states inches. Use that unit setting when inserting or scaling the source. The manufacturer sheet identifies amperage: 400A CLASS T FUSE PROVISIONS.; sccr: 100kA with Fuse Installed (Class T) SWITCH 2.19; phase: 3-Phase 4-Wire; voltage: 208Y/120V; amperage: 400A.


## In plain English

### Using the ReliaMod Outline Drawing, Main Fusible Switch Module, RMM3F4R reference

ABB ReliaMod Outline Drawing, Main Fusible Switch Module, RMM3F4R: switchboard or switchgear reference for panel arrangement and interfaces to adjacent equipment. Manufacturer reference 1TQC1333E0054.

### A simple example

Use 1TQC1333E0054.pdf revision B to read the original manufacturer sheet and its annotations. Start with page 1 for the dimension or mounting references identified in the document.

### What the drawings help you do

Use 1TQC1333E0054.pdf revision B to read the original manufacturer sheet and its annotations. Start with page 1 for the dimension or mounting references identified in the document.

### Before using this reference

- 1TQC1333E0054.pdf, page 1, includes bottom view, front view, side view, top view. Select the view matching your GA orientation.
- The unit note on 1TQC1333E0054.pdf, page 1, states inches. Use that unit setting when inserting or scaling the source.
- The manufacturer sheet identifies amperage: 400A CLASS T FUSE PROVISIONS.; sccr: 100kA with Fuse Installed (Class T) SWITCH 2.19; phase: 3-Phase 4-Wire; voltage: 208Y/120V; amperage: 400A.
- Check enclosure arrangement, incoming connection position and the view used for the adjoining section. A single module drawing does not establish the dimensions or fault rating of an assembled board.

### What can I use the ReliaMod Outline Drawing, Main Fusible Switch Module, RMM3F4R reference for?

Use this switchboard or switchgear reference for panel arrangement and interfaces to adjacent equipment. 1TQC1333E0054.pdf, page 1, includes bottom view, front view, side view, top view. Select the view matching your GA orientation.

### Which manufacturer reference identifies this drawing?

ABB reference 1TQC1333E0054. The file list retains the original source and recorded revision.

### Terms


Concept diagram: Identify ReliaMod Outline Drawing, Main Fusible Switch Module, RMM3F4R → Select the drawing or model → Check the mounting interface
1TQC1333E0054.pdf, page 1, includes bottom view, front view, side view, top view. Select the view matching your GA orientation. The unit note on 1TQC1333E0054.pdf, page 1, states inches. Use that unit setting when inserting or scaling the source. The manufacturer sheet identifies amperage: 400A CLASS T FUSE PROVISIONS.; sccr: 100kA with Fuse Installed (Class T) SWITCH 2.19; phase: 3-Phase 4-Wire; voltage: 208Y/120V; amperage: 400A.

- [ABB source](https://search.abb.com/library/Download.aspx?DocumentID=1TQC1333E0054&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=B)


## Which file should I choose?

Use 1TQC1333E0054.pdf revision B to read the original manufacturer sheet and its annotations. Start with page 1 for the dimension or mounting references identified in the document.

## Official files

- 1TQC1333E0054.pdf (PDF): https://search.abb.com/library/Download.aspx?DocumentID=1TQC1333E0054&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=B
  Site download: https://eloragrid.ai/tools/cad-library/download/abb-reliamod-outline-drawing-main-fusible-switch-module-rmm3f4r-ff7ac12800/7d154020003ed8f89cd6
  Hosting basis: no-explicit-prohibition; publisher attribution: ABB; reviewed: 2026-11-04
  Rights review: Reviewed the available source, embedded drawing text and archive notices. No explicit applicable redistribution prohibition was identified. Rights remain unknown; no licence or manufacturer endorsement is asserted.; evidence: https://search.abb.com/library/Download.aspx?DocumentID=1TQC1333E0054&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=B
  Purpose: Manufacturer drawing reference 1TQC1333E0054; acquired: true; redistribution: unknown; SHA-256: 7d154020003ed8f89cd6b765f909061db9ae6c6bf2ba2182db85e000eccacbf7; revision: B