{"id":"abb-xt2-4p-fixed-mc-up-627c3f1bf9","name":"XT2 4p FIXED MC UP","manufacturer":"ABB","category":"breakers","description":"ABB XT2 4p FIXED MC UP: breaker or breaker-accessory reference for breaker compartment and mounting interfaces. Manufacturer reference 1SDH001295R0295.","equipment":["XT2 4p FIXED MC UP","XT2 4p PLUG-IN MC UP","XT2 4p WITHDRAWABLE MC UP"],"keywords":["XT2 4p FIXED MC UP","","1SDH001295R0295","Switchgear and switchboards","breaker","breaker compartment and mounting interfaces","breaker or breaker-accessory reference","XT2 4p PLUG-IN MC UP","1SDH001295R0335","Connections, wiring and earthing","XT2 4p WITHDRAWABLE MC UP","1SDH001295R0377"],"markets":["Global"],"marketNote":"Confirm the exact regional configuration against the selected manufacturer drawing.","kind":"drawing","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","officialEvidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","sourcePublisher":"ABB","formats":["STEP"],"availability":"direct","accessNote":"3 original files are available to download here. Manufacturer sources and revisions are listed below.","checkedAt":"2026-11-03","files":[{"id":"564dabf0eaa3f110d23c","name":"1SDH001295R0295_1PA_001_00_XT2_4P_FIXED_MC_SUP.stp","format":"STEP","purpose":"Manufacturer drawing reference 1SDH001295R0295","url":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","availability":"direct","sha256":"564dabf0eaa3f110d23c3f85cda744ce596ca5f480a62ffebe9fc35a7a81911c","bytes":354887,"retrievedAt":"2026-11-03T01:50:18.345618Z","filenameBasis":"response-header","revision":"A","hosted":true,"redistribution":"unknown","validation":"signature-checked","documentNumber":"1SDH001295R0295","latestRevisionUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch","rightsReview":{"checkedAt":"2026-11-04","sources":["https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"],"note":"Reviewed the available source, embedded drawing text and archive notices. No explicit applicable redistribution prohibition was identified. Rights remain unknown; no licence or manufacturer endorsement is asserted."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-04","evidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","attribution":"ABB"},"delivery":{"kind":"original","name":"1SDH001295R0295_1PA_001_00_XT2_4P_FIXED_MC_SUP.stp","format":"STEP","sha256":"564dabf0eaa3f110d23c3f85cda744ce596ca5f480a62ffebe9fc35a7a81911c","bytes":354887,"includes":["1SDH001295R0295_1PA_001_00_XT2_4P_FIXED_MC_SUP.stp"]},"downloadUrl":"https://eloragrid.ai/tools/cad-library/download/abb-xt2-4p-fixed-mc-up-627c3f1bf9/564dabf0eaa3f110d23c"},{"id":"ead475500059ad6c8891","name":"1SDH001295R0335_1PA_001_00_XT2_4P_PLUG_IN_MC_SUP.stp","format":"STEP","purpose":"Manufacturer drawing reference 1SDH001295R0335","url":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0335&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","availability":"direct","sha256":"ead475500059ad6c8891a2020150f5a239e9774ad7620d5318a8bbe11bbf3bdf","bytes":355463,"retrievedAt":"2026-11-03T01:50:20.131987Z","filenameBasis":"response-header","revision":"A","hosted":true,"redistribution":"unknown","validation":"signature-checked","documentNumber":"1SDH001295R0335","latestRevisionUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0335&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch","rightsReview":{"checkedAt":"2026-11-04","sources":["https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0335&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"],"note":"Reviewed the available source, embedded drawing text and archive notices. No explicit applicable redistribution prohibition was identified. Rights remain unknown; no licence or manufacturer endorsement is asserted."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-04","evidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0335&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","attribution":"ABB"},"delivery":{"kind":"original","name":"1SDH001295R0335_1PA_001_00_XT2_4P_PLUG_IN_MC_SUP.stp","format":"STEP","sha256":"ead475500059ad6c8891a2020150f5a239e9774ad7620d5318a8bbe11bbf3bdf","bytes":355463,"includes":["1SDH001295R0335_1PA_001_00_XT2_4P_PLUG_IN_MC_SUP.stp"]},"downloadUrl":"https://eloragrid.ai/tools/cad-library/download/abb-xt2-4p-fixed-mc-up-627c3f1bf9/ead475500059ad6c8891"},{"id":"6d771e94a936c79953a8","name":"1SDH001295R0377_1PA_001_00_XT2_4P_WITHDRAWABLE_MC_SUP.stp","format":"STEP","purpose":"Manufacturer drawing reference 1SDH001295R0377","url":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0377&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","availability":"direct","sha256":"6d771e94a936c79953a84ed3f6e46b09b92359b4aa558b5a3ab58f3160b503bb","bytes":355473,"retrievedAt":"2026-11-03T01:50:23.318498Z","filenameBasis":"response-header","revision":"A","hosted":true,"redistribution":"unknown","validation":"signature-checked","documentNumber":"1SDH001295R0377","latestRevisionUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0377&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch","rightsReview":{"checkedAt":"2026-11-04","sources":["https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0377&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"],"note":"Reviewed the available source, embedded drawing text and archive notices. No explicit applicable redistribution prohibition was identified. Rights remain unknown; no licence or manufacturer endorsement is asserted."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-04","evidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0377&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A","attribution":"ABB"},"delivery":{"kind":"original","name":"1SDH001295R0377_1PA_001_00_XT2_4P_WITHDRAWABLE_MC_SUP.stp","format":"STEP","sha256":"6d771e94a936c79953a84ed3f6e46b09b92359b4aa558b5a3ab58f3160b503bb","bytes":355473,"includes":["1SDH001295R0377_1PA_001_00_XT2_4P_WITHDRAWABLE_MC_SUP.stp"]},"downloadUrl":"https://eloragrid.ai/tools/cad-library/download/abb-xt2-4p-fixed-mc-up-627c3f1bf9/6d771e94a936c79953a8"}],"fileClasses":["manufacturer STEP file"],"configurationNote":"The supplied configuration is “XT2 4p FIXED MC UP”. Keep those frame, mounting and accessory codes with the inserted drawing.","technicalFacts":[{"label":"Source configurations grouped on this page","value":"XT2 4p FIXED MC UP; XT2 4p PLUG-IN MC UP; XT2 4p WITHDRAWABLE MC UP","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Manufacturer reference","value":"1SDH001295R0295","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Document revision","value":"A","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Model envelope: 1SDH001295R0295_1PA_001_00_XT2_4P_FIXED_MC_SUP.stp","value":"111.5 × 39 × 44 mm (approximate X × Y × Z bounds of the tessellated source model)","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Manufacturer reference","value":"1SDH001295R0335","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0335&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Document revision","value":"A","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0335&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Model envelope: 1SDH001295R0335_1PA_001_00_XT2_4P_PLUG_IN_MC_SUP.stp","value":"111.5 × 39 × 44 mm (approximate X × Y × Z bounds of the tessellated source model)","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0335&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Manufacturer reference","value":"1SDH001295R0377","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0377&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Document revision","value":"A","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0377&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Model envelope: 1SDH001295R0377_1PA_001_00_XT2_4P_WITHDRAWABLE_MC_SUP.stp","value":"111.5 × 39 × 44 mm (approximate X × Y × Z bounds of the tessellated source model)","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0377&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"}],"drawingNumber":"1SDH001295R0295","equipmentFacts":[{"label":"Equipment / resource","value":"XT2 4p FIXED MC UP"},{"label":"Manufacturer","value":"ABB"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Manufacturer drawing","value":"1SDH001295R0295"},{"label":"Source configurations grouped on this page","value":"XT2 4p FIXED MC UP; XT2 4p PLUG-IN MC UP; XT2 4p WITHDRAWABLE MC UP"},{"label":"Manufacturer reference","value":"1SDH001295R0295"},{"label":"Document revision","value":"A"},{"label":"Model envelope: 1SDH001295R0295_1PA_001_00_XT2_4P_FIXED_MC_SUP.stp","value":"111.5 × 39 × 44 mm (approximate X × Y × Z bounds of the tessellated source model)"},{"label":"Manufacturer reference","value":"1SDH001295R0335"},{"label":"Model envelope: 1SDH001295R0335_1PA_001_00_XT2_4P_PLUG_IN_MC_SUP.stp","value":"111.5 × 39 × 44 mm (approximate X × Y × Z bounds of the tessellated source model)"},{"label":"Manufacturer reference","value":"1SDH001295R0377"},{"label":"Model envelope: 1SDH001295R0377_1PA_001_00_XT2_4P_WITHDRAWABLE_MC_SUP.stp","value":"111.5 × 39 × 44 mm (approximate X × Y × Z bounds of the tessellated source model)"},{"label":"Listed file formats","value":"STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"3 interactive model variants"},{"label":"Recorded revisions","value":"A"},{"label":"Source checked","value":"2026-11-03"},{"label":"Download access","value":"Email registration for site downloads; official source links are also available"}],"previewImage":"/tools/cad-library/preview/abb-xt2-4p-fixed-mc-up-627c3f1bf9/ead475500059ad6c8891?asset=ead475500059ad6c8891a2020150f5a239e9774ad7620d5318a8bbe11bbf3bdf&view=thumb&v=22cbe661825850e7","relatedReferences":[{"name":"Air circuit breaker","url":"https://eloragrid.ai/objects/ga-air-circuit-breaker"},{"name":"Moulded-case circuit breaker","url":"https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker"}],"fileChoiceGuidance":["Use 1SDH001295R0295_1PA_001_00_XT2_4P_FIXED_MC_SUP.stp revision A for the supplied solid assembly in your 3D layout. Use 1SDH001295R0335_1PA_001_00_XT2_4P_PLUG_IN_MC_SUP.stp revision A for the supplied solid assembly in your 3D layout. Match the XT2 4p PLUG-IN MC UP configuration named by ABB. Use 1SDH001295R0377_1PA_001_00_XT2_4P_WITHDRAWABLE_MC_SUP.stp revision A for the supplied solid assembly in your 3D layout. Match the XT2 4p WITHDRAWABLE MC UP configuration named by ABB."],"plainEnglish":{"title":"Using the XT2 4p FIXED MC UP reference","introduction":"ABB XT2 4p FIXED MC UP: breaker or breaker-accessory reference for breaker compartment and mounting interfaces. Manufacturer reference 1SDH001295R0295.","example":"Use 1SDH001295R0295_1PA_001_00_XT2_4P_FIXED_MC_SUP.stp revision A for the supplied solid assembly in your 3D layout. Match the XT2 4p FIXED MC UP configuration named by ABB.","drawings":"Use 1SDH001295R0295_1PA_001_00_XT2_4P_FIXED_MC_SUP.stp revision A for the supplied solid assembly in your 3D layout. Use 1SDH001295R0335_1PA_001_00_XT2_4P_PLUG_IN_MC_SUP.stp revision A for the supplied solid assembly in your 3D layout. Match the XT2 4p PLUG-IN MC UP configuration named by ABB. Use 1SDH001295R0377_1PA_001_00_XT2_4P_WITHDRAWABLE_MC_SUP.stp revision A for the supplied solid assembly in your 3D layout. Match the XT2 4p WITHDRAWABLE MC UP configuration named by ABB.","terms":[],"diagram":"flow","steps":["Identify XT2 4p FIXED MC UP","Select the drawing or model","Check the mounting interface"],"caption":"The supplied configuration is “XT2 4p FIXED MC UP”. Keep those frame, mounting and accessory codes with the inserted drawing.","sources":[{"label":"ABB source","url":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH001295R0295&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=A"}],"questions":[{"question":"What can I use the XT2 4p FIXED MC UP reference for?","answer":"Use this breaker or breaker-accessory reference for breaker compartment and mounting interfaces. The supplied configuration is “XT2 4p FIXED MC UP”. Keep those frame, mounting and accessory codes with the inserted drawing."},{"question":"Which manufacturer reference identifies this drawing?","answer":"ABB reference 1SDH001295R0295. The file list retains the original source and recorded revision."}],"checklist":["The supplied configuration is “XT2 4p FIXED MC UP”. Keep those frame, mounting and accessory codes with the inserted drawing.","Use the exact frame, pole and mounting configuration named by this reference. Door drilling, connection and accessory drawings describe those interfaces rather than a complete switchboard.","1SDH001295R0295_1PA_001_00_XT2_4P_FIXED_MC_SUP.stp has approximate model bounds of 111.5 × 39 × 44 mm (approximate X × Y × Z bounds of the tessellated source model). Compare these model axes with the installation orientation; mounting and service clearances are separate requirements.","The supplied configuration is “XT2 4p PLUG-IN MC UP”. Keep those frame, mounting and accessory codes with the inserted drawing.","1SDH001295R0335_1PA_001_00_XT2_4P_PLUG_IN_MC_SUP.stp has approximate model bounds of 111.5 × 39 × 44 mm (approximate X × Y × Z bounds of the tessellated source model). Compare these model axes with the installation orientation; mounting and service clearances are separate requirements.","The supplied configuration is “XT2 4p WITHDRAWABLE MC UP”. Keep those frame, mounting and accessory codes with the inserted drawing.","1SDH001295R0377_1PA_001_00_XT2_4P_WITHDRAWABLE_MC_SUP.stp has approximate model bounds of 111.5 × 39 × 44 mm (approximate X × Y × Z bounds of the tessellated source model). Compare these model axes with the installation orientation; mounting and service clearances are separate requirements.","This page groups 3 source references for the same configuration or model geometry. The file list retains the separate formats and source revisions."]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/abb-xt2-4p-fixed-mc-up-627c3f1bf9"}