{"id":"abb-xt5-4p-p-w-400a-hr-bottom-iec-3456a187b9","name":"XT5 4p P-W 400A HR bottom (IEC)","manufacturer":"ABB","category":"breakers","description":"ABB XT5 4p P-W 400A HR bottom (IEC): breaker or breaker-accessory reference for breaker compartment and mounting interfaces. Manufacturer reference 1SDH002065A1600.","equipment":["XT5 4p P-W 400A HR bottom (IEC)"],"keywords":["XT5 4p P-W 400A HR bottom (IEC)","","1SDH002065A1600","Switchgear and switchboards","breaker","breaker compartment and mounting interfaces","breaker or breaker-accessory reference"],"markets":["Global"],"marketNote":"Confirm the exact regional configuration against the selected manufacturer drawing.","kind":"drawing","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002065A1600&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A","officialEvidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002065A1600&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A","sourcePublisher":"ABB","formats":["STEP"],"availability":"direct","accessNote":"1 original file is available to download here. Manufacturer sources and revisions are listed below.","checkedAt":"2026-11-04","files":[{"id":"c730b6460bae7a795f89","name":"1SDH002065A1600_XT5_4p_P_W_400A_HR_bottom__IEC_.stp","format":"STEP","purpose":"Manufacturer drawing reference 1SDH002065A1600","url":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002065A1600&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A","availability":"direct","sha256":"c730b6460bae7a795f89b32cc661a96931c16052bac10e73a7d3383d72db2942","bytes":78979197,"retrievedAt":"2026-11-04T04:00:41Z","filenameBasis":"response-header","revision":"A","hosted":true,"redistribution":"unknown","validation":"signature-checked","documentNumber":"1SDH002065A1600","latestRevisionUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002065A1600&LanguageCode=en&DocumentPartId=&Action=Launch","rightsReview":{"checkedAt":"2026-11-04","sources":["https://search.abb.com/library/Download.aspx?DocumentID=1SDH002065A1600&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A"],"note":"Reviewed the available source, embedded drawing text and archive notices. No explicit applicable redistribution prohibition was identified. Rights remain unknown; no licence or manufacturer endorsement is asserted."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-04","evidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002065A1600&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A","attribution":"ABB"},"delivery":{"kind":"original","name":"1SDH002065A1600_XT5_4p_P_W_400A_HR_bottom__IEC_.stp","format":"STEP","sha256":"c730b6460bae7a795f89b32cc661a96931c16052bac10e73a7d3383d72db2942","bytes":78979197,"includes":["1SDH002065A1600_XT5_4p_P_W_400A_HR_bottom__IEC_.stp"]},"downloadUrl":"https://eloragrid.ai/tools/cad-library/download/abb-xt5-4p-p-w-400a-hr-bottom-iec-3456a187b9/c730b6460bae7a795f89"}],"fileClasses":["manufacturer STEP file"],"configurationNote":"The supplied configuration is “XT5 4p P-W 400A HR bottom (IEC)”. Keep those frame, mounting and accessory codes with the inserted drawing.","technicalFacts":[{"label":"Manufacturer reference","value":"1SDH002065A1600","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002065A1600&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Document revision","value":"A","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002065A1600&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A"}],"drawingNumber":"1SDH002065A1600","equipmentFacts":[{"label":"Equipment / resource","value":"XT5 4p P-W 400A HR bottom (IEC)"},{"label":"Manufacturer","value":"ABB"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Manufacturer drawing","value":"1SDH002065A1600"},{"label":"Manufacturer reference","value":"1SDH002065A1600"},{"label":"Document revision","value":"A"},{"label":"Listed file formats","value":"STEP"},{"label":"Listed files","value":"1"},{"label":"Available previews","value":"No browser preview; original files are downloadable"},{"label":"Recorded revisions","value":"A"},{"label":"Source checked","value":"2026-11-04"},{"label":"Download access","value":"Email registration for site downloads; official source links are also available"}],"relatedReferences":[{"name":"Air circuit breaker","url":"https://eloragrid.ai/objects/ga-air-circuit-breaker"},{"name":"Moulded-case circuit breaker","url":"https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker"}],"fileChoiceGuidance":["Use 1SDH002065A1600_XT5_4p_P_W_400A_HR_bottom__IEC_.stp revision A for the supplied solid assembly in your 3D layout."],"plainEnglish":{"title":"Using the XT5 4p P-W 400A HR bottom (IEC) reference","introduction":"ABB XT5 4p P-W 400A HR bottom (IEC): breaker or breaker-accessory reference for breaker compartment and mounting interfaces. Manufacturer reference 1SDH002065A1600.","example":"Use 1SDH002065A1600_XT5_4p_P_W_400A_HR_bottom__IEC_.stp revision A for the supplied solid assembly in your 3D layout. Match the XT5 4p P-W 400A HR bottom (IEC) configuration named by ABB.","drawings":"Use 1SDH002065A1600_XT5_4p_P_W_400A_HR_bottom__IEC_.stp revision A for the supplied solid assembly in your 3D layout.","terms":[],"diagram":"flow","steps":["Identify XT5 4p P-W 400A HR bottom (IEC)","Select the drawing or model","Check the mounting interface"],"caption":"The supplied configuration is “XT5 4p P-W 400A HR bottom (IEC)”. Keep those frame, mounting and accessory codes with the inserted drawing.","sources":[{"label":"ABB source","url":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002065A1600&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A"}],"questions":[{"question":"What can I use the XT5 4p P-W 400A HR bottom (IEC) reference for?","answer":"Use this breaker or breaker-accessory reference for breaker compartment and mounting interfaces. The supplied configuration is “XT5 4p P-W 400A HR bottom (IEC)”. Keep those frame, mounting and accessory codes with the inserted drawing."},{"question":"Which manufacturer reference identifies this drawing?","answer":"ABB reference 1SDH002065A1600. The file list retains the original source and recorded revision."}],"checklist":["The supplied configuration is “XT5 4p P-W 400A HR bottom (IEC)”. Keep those frame, mounting and accessory codes with the inserted drawing.","Use the exact frame, pole and mounting configuration named by this reference. Door drilling, connection and accessory drawings describe those interfaces rather than a complete switchboard."]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/abb-xt5-4p-p-w-400a-hr-bottom-iec-3456a187b9"}