{"id":"abb-xt7-m-iii-iv-withdrawable-version-terminals-ef-and-es-49e4d7b3d1","name":"XT7 M III-IV withdrawable version terminals EF and ES","manufacturer":"ABB","category":"breakers","description":"ABB XT7 M III-IV withdrawable version terminals EF and ES: breaker connection or accessory reference for breaker compartment and mounting interfaces. Manufacturer reference 1SDH002013A1123.","equipment":["XT7 M III-IV withdrawable version terminals EF and ES"],"keywords":["XT7 M III-IV withdrawable version terminals EF and ES","","1SDH002013A1123","Connections, wiring and earthing","breaker","breaker compartment and mounting interfaces","breaker connection or accessory reference"],"markets":["Global"],"marketNote":"Confirm the exact regional configuration against the selected manufacturer drawing.","kind":"drawing","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002013A1123&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A","officialEvidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002013A1123&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A","sourcePublisher":"ABB","formats":["DXF"],"availability":"request","accessNote":"Source-only. Open the manufacturer reference or request the drawing for your selected equipment.","checkedAt":"2026-11-03","files":[{"id":"e6136a2f65433bfbd584","name":"1SDH002013A1123_1DR_001_00_XT7_W_TOGGLE_WITH_TERMINALS_EF_ES.dxf","format":"DXF","purpose":"Manufacturer drawing reference 1SDH002013A1123","url":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002013A1123&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A","availability":"direct","sha256":"e6136a2f65433bfbd58436204f19875ebb20006493e2c6c6c829844a122a8796","bytes":3236284,"retrievedAt":"2026-11-03T02:22:50.259024Z","filenameBasis":"response-header","revision":"A","hosted":false,"redistribution":"restricted","validation":"signature-checked","documentNumber":"1SDH002013A1123","latestRevisionUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002013A1123&LanguageCode=en&DocumentPartId=&Action=Launch","rightsReview":{"checkedAt":"2026-11-04","sources":["https://search.abb.com/library/Download.aspx?DocumentID=1SDH002013A1123&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A"],"note":"Copying or disclosure expressly prohibited. The original and previews derived from it remain off the public delivery list."}}],"fileClasses":["manufacturer DXF file"],"configurationNote":"This reference covers the connection or accessory named in “XT7 M III-IV withdrawable version terminals EF and ES”. It is not the complete breaker-and-compartment assembly. The supplied configuration is “XT7 M III-IV withdrawable version terminals EF and ES”. Keep those frame, mounting and accessory codes with the inserted drawing.","technicalFacts":[{"label":"Manufacturer reference","value":"1SDH002013A1123","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002013A1123&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A"},{"label":"Document revision","value":"A","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002013A1123&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A"}],"drawingNumber":"1SDH002013A1123","equipmentFacts":[{"label":"Equipment / resource","value":"XT7 M III-IV withdrawable version terminals EF and ES"},{"label":"Manufacturer","value":"ABB"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Manufacturer drawing","value":"1SDH002013A1123"},{"label":"Manufacturer reference","value":"1SDH002013A1123"},{"label":"Document revision","value":"A"},{"label":"Listed file formats","value":"DXF"},{"label":"Listed files","value":"1"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"A"},{"label":"Source checked","value":"2026-11-03"},{"label":"Download access","value":"Use the official manufacturer source or request the exact drawing"}],"relatedReferences":[{"name":"Air circuit breaker","url":"https://eloragrid.ai/objects/ga-air-circuit-breaker"},{"name":"Moulded-case circuit breaker","url":"https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker"}],"fileChoiceGuidance":["Use 1SDH002013A1123_1DR_001_00_XT7_W_TOGGLE_WITH_TERMINALS_EF_ES.dxf revision A for editable DXF drawing geometry. Keep its original layers and dimension annotations when inserting the drawing."],"plainEnglish":{"title":"Using the XT7 M III-IV withdrawable version terminals EF and ES reference","introduction":"ABB XT7 M III-IV withdrawable version terminals EF and ES: breaker connection or accessory reference for breaker compartment and mounting interfaces. Manufacturer reference 1SDH002013A1123.","example":"Use 1SDH002013A1123_1DR_001_00_XT7_W_TOGGLE_WITH_TERMINALS_EF_ES.dxf revision A for editable DXF drawing geometry. Keep its original layers and dimension annotations when inserting the drawing.","drawings":"Use 1SDH002013A1123_1DR_001_00_XT7_W_TOGGLE_WITH_TERMINALS_EF_ES.dxf revision A for editable DXF drawing geometry. Keep its original layers and dimension annotations when inserting the drawing.","terms":[],"diagram":"flow","steps":["Identify XT7 M III-IV withdrawable version terminals EF and ES","Select the drawing or model","Check the mounting interface"],"caption":"This reference covers the connection or accessory named in “XT7 M III-IV withdrawable version terminals EF and ES”. It is not the complete breaker-and-compartment assembly. The supplied configuration is “XT7 M III-IV withdrawable version terminals EF and ES”. Keep those frame, mounting and accessory codes with the inserted drawing.","sources":[{"label":"ABB source","url":"https://search.abb.com/library/Download.aspx?DocumentID=1SDH002013A1123&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=A"}],"questions":[{"question":"What can I use the XT7 M III-IV withdrawable version terminals EF and ES reference for?","answer":"Use this breaker connection or accessory reference for breaker compartment and mounting interfaces. This reference covers the connection or accessory named in “XT7 M III-IV withdrawable version terminals EF and ES”. It is not the complete breaker-and-compartment assembly."},{"question":"Which manufacturer reference identifies this drawing?","answer":"ABB reference 1SDH002013A1123. The file list retains the original source and recorded revision."}],"checklist":["This reference covers the connection or accessory named in “XT7 M III-IV withdrawable version terminals EF and ES”. It is not the complete breaker-and-compartment assembly.","The supplied configuration is “XT7 M III-IV withdrawable version terminals EF and ES”. Keep those frame, mounting and accessory codes with the inserted drawing.","Use the exact frame, pole and mounting configuration named by this reference. Door drilling, connection and accessory drawings describe those interfaces rather than a complete switchboard."]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/abb-xt7-m-iii-iv-withdrawable-version-terminals-ef-and-es-49e4d7b3d1"}