{"id":"drawing-cfs-1pcc30-dc-12dc84d87ef3","name":"CFS-1PCC30-DC disconnecting switch","manufacturer":"AutomationDirect","category":"switchgear","description":"CAD drawings for CFS-1PCC30-DC help place the selected disconnecting switch and coordinate its mounting, connection access and service space. A disconnecting switch provides the switching or isolation function stated for the selected product. The switch body, handle and connecting operating parts may need separate drawings.","equipment":["Gladiator CFS Series Disconnects"],"keywords":["CFS-1PCC30-DC","Gladiator CFS Series Disconnects","CFS-1PCC30-DC.dwg","CFS-1PCC30-DC disconnecting switch","CAD drawings for CFS-1PCC30-DC help place the selected disconnecting switch and coordinate its mounting, connection access and service space. A disconnecting switch provides the switching or isolation function stated for the selected product. The switch body, handle and connecting operating parts may need separate drawings."],"markets":["US","Global"],"marketNote":"US and Canada supplier catalogue; globally discoverable. Regional suitability must be verified for exact part.","kind":"drawing","sourceUrl":"https://support.automationdirect.com/docs/drawings.html","officialEvidenceUrl":"https://support.automationdirect.com/docs/drawings.html","sourcePublisher":"AutomationDirect","formats":["DWG"],"availability":"direct","accessNote":"Original CAD is retained privately; explicit publisher restrictions keep public downloads on the official route. Use Request CAD for exact variants.","checkedAt":"2026-10-13T00:00:00.000Z","files":[{"id":"cad-cfs-1pcc30-dc-dwg-6dfafa10c3ab90","name":"cfsdisconnects.zip","format":"ZIP","purpose":"Contains CFS-1PCC30-DC.dwg; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","availability":"direct","bytes":644201,"sha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Power Products/Gladiator CFS Series Disconnects/CFS-1PCC30-DC.dwg"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Power Products/Gladiator CFS Series Disconnects/CFS-1PCC30-DC.dwg"},{"id":"cad-cfs-1pcc30-dwg-2156a11b4a3e8a","name":"cfsdisconnects.zip","format":"ZIP","purpose":"Contains CFS-1PCC30.dwg; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","availability":"direct","bytes":644201,"sha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Power Products/Gladiator CFS Series Disconnects/CFS-1PCC30.dwg"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Power Products/Gladiator CFS Series Disconnects/CFS-1PCC30.dwg"},{"id":"cad-cfs-1pm30-dc-dwg-43ef4534a92bd1","name":"cfsdisconnects.zip","format":"ZIP","purpose":"Contains CFS-1PM30-DC.dwg; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","availability":"direct","bytes":644201,"sha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Power Products/Gladiator CFS Series Disconnects/CFS-1PM30-DC.dwg"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Power Products/Gladiator CFS Series Disconnects/CFS-1PM30-DC.dwg"},{"id":"cad-cfs-1pm30-dwg-e117bd41d1340b","name":"cfsdisconnects.zip","format":"ZIP","purpose":"Contains CFS-1PM30.dwg; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","availability":"direct","bytes":644201,"sha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Power Products/Gladiator CFS Series Disconnects/CFS-1PM30.dwg"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Power Products/Gladiator CFS Series Disconnects/CFS-1PM30.dwg"}],"fileClasses":["mechanical CAD","dimensioned drawings"],"configurationNote":"The verified native member is Power Products/Gladiator CFS Series Disconnects/CFS-1PCC30-DC.dwg. Its identity was checked against the acquired manufacturer archive. Coordinate the switch mounting, conductor approach and operator access with the enclosure arrangement. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: CFS-1PCC30, CFS-1PM30-DC, CFS-1PM30. Grouping does not establish electrical interchangeability.","drawingReference":{"family":"Gladiator CFS Series Disconnects","filenames":["CFS-1PCC30-DC.dwg","CFS-1PCC30.dwg","CFS-1PM30-DC.dwg","CFS-1PM30.dwg"],"parentId":"ad-cfsdisconnects"},"equipmentFacts":[{"label":"Equipment / resource","value":"CFS-1PCC30-DC disconnecting switch"},{"label":"Manufacturer","value":"AutomationDirect"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Listed file formats","value":"DWG"},{"label":"Listed files","value":"4"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-10-13"},{"label":"Download access","value":"Use the official manufacturer source or request the exact drawing"}],"relatedReferences":[{"name":"AutomationDirect Gladiator CFS disconnects","url":"https://eloragrid.ai/objects/automationdirect-gladiator-cfs-disconnects"},{"name":"AutomationDirect CFS-1PCC30-DC disconnecting switch","url":"https://eloragrid.ai/objects/ga-cfs-1pcc30-dc-12dc84d87ef3"},{"name":"Switchgear panel","url":"https://eloragrid.ai/objects/switchgear-panel"},{"name":"Switchboard","url":"https://eloragrid.ai/objects/switchboard"},{"name":"Ring main unit","url":"https://eloragrid.ai/objects/ring-main-unit"}],"nativeFiles":[{"filename":"Power Products/Gladiator CFS Series Disconnects/CFS-1PCC30-DC.dwg","format":"DWG","bytes":167468,"sha256":"a8a0d2738c32192134f147faa13e7c6cf63f028d40075c3106c3730ccade9898","archiveSha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","sourceUrl":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","signature":"AC1015"},{"filename":"Power Products/Gladiator CFS Series Disconnects/CFS-1PCC30.dwg","format":"DWG","bytes":167409,"sha256":"ca5583379da370a7db5bef94980c2e2727f3302917a0fbd5a48f3d2035a58293","archiveSha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","sourceUrl":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","signature":"AC1015"},{"filename":"Power Products/Gladiator CFS Series Disconnects/CFS-1PM30-DC.dwg","format":"DWG","bytes":167551,"sha256":"fffe4872e7cb6f4e269a892f50b43445f27f71fec0df6383ca36f0bb2e1e7de6","archiveSha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","sourceUrl":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","signature":"AC1015"},{"filename":"Power Products/Gladiator CFS Series Disconnects/CFS-1PM30.dwg","format":"DWG","bytes":167480,"sha256":"f8b0c3bb10acd31d69abcc4d2cbbbf3fd5f6f3c3652053050c31dea1691d62b0","archiveSha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","sourceUrl":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","signature":"AC1015"}],"fileChoiceGuidance":["The verified native member is Power Products/Gladiator CFS Series Disconnects/CFS-1PCC30-DC.dwg. Its identity was checked against the acquired manufacturer archive. Coordinate the switch mounting, conductor approach and operator access with the enclosure arrangement. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: CFS-1PCC30, CFS-1PM30-DC, CFS-1PM30. Grouping does not establish electrical interchangeability."],"plainEnglish":{"title":"What the equipment does","introduction":"A disconnector separates equipment from its supply under its specified conditions. Whether it can also interrupt load current depends on the device's switching rating.","example":"In a switchyard, a disconnector provides an isolation point for a circuit section within the site's operating procedure.","drawings":"The verified native member is Power Products/Gladiator CFS Series Disconnects/CFS-1PCC30-DC.dwg. Its identity was checked against the acquired manufacturer archive. Coordinate the switch mounting, conductor approach and operator access with the enclosure arrangement. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: CFS-1PCC30, CFS-1PM30-DC, CFS-1PM30. Grouping does not establish electrical interchangeability.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Find CFS-1PCC30-DC in the official archive","Open the matching original drawing","Coordinate disconnect interfaces"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"AutomationDirect official source","url":"https://support.automationdirect.com/docs/drawings.html"}],"profileId":"disconnect","checklist":["Confirm that the project schedule calls for CFS-1PCC30-DC or an explicitly documented associated drawing identity.","Coordinate the switch mounting, conductor approach and operator access with the enclosure arrangement.","Check the units and drawing revision before measuring or inserting geometry into a project.","Coordinate the mounting and connection faces with adjacent equipment, enclosure access and the cable route.","Verify ratings, compatible accessories and installation clearances using the manufacturer documentation for the exact device."],"questions":[{"question":"What does the CFS-1PCC30-DC reference verify?","answer":"It verifies the acquired native drawing identity and its place in the official Gladiator CFS disconnect hardware source collection. The source member and checksums identify the reviewed file; they do not establish the selected device rating or current revision."},{"question":"How should I use the original file?","answer":"Download the unchanged manufacturer archive from the official route and locate Power Products/Gladiator CFS Series Disconnects/CFS-1PCC30-DC.dwg. Check the drawing units and revision before using its geometry in the project."},{"question":"Can grouped drawing identities replace one another electrically?","answer":"No. Mechanical drawing grouping only avoids separate pages for matching geometry, views or voltage aliases. Confirm exact electrical function, connection arrangement and manufacturer compatibility separately."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/drawing-cfs-1pcc30-dc-12dc84d87ef3"}