{"id":"drawing-cfs-2pcc30-808054d211f0","name":"CFS-2PCC30 disconnecting switch","manufacturer":"AutomationDirect","category":"switchgear","description":"CAD drawings for CFS-2PCC30 help place the selected disconnecting switch and coordinate its mounting, connection access and service space. A disconnecting switch provides the switching or isolation function stated for the selected product. The switch body, handle and connecting operating parts may need separate drawings.","equipment":["Gladiator CFS Series Disconnects"],"keywords":["CFS-2PCC30","Gladiator CFS Series Disconnects","CFS-2PCC30.dwg","CFS-2PCC30 disconnecting switch","CAD drawings for CFS-2PCC30 help place the selected disconnecting switch and coordinate its mounting, connection access and service space. A disconnecting switch provides the switching or isolation function stated for the selected product. The switch body, handle and connecting operating parts may need separate drawings."],"markets":["US","Global"],"marketNote":"US and Canada supplier catalogue; globally discoverable. Regional suitability must be verified for exact part.","kind":"drawing","sourceUrl":"https://support.automationdirect.com/docs/drawings.html","officialEvidenceUrl":"https://support.automationdirect.com/docs/drawings.html","sourcePublisher":"AutomationDirect","formats":["DWG"],"availability":"direct","accessNote":"Original CAD is retained privately; explicit publisher restrictions keep public downloads on the official route. Use Request CAD for exact variants.","checkedAt":"2026-10-13T00:00:00.000Z","files":[{"id":"cad-cfs-2pcc30-dwg-99e5db7d08970a","name":"cfsdisconnects.zip","format":"ZIP","purpose":"Contains CFS-2PCC30.dwg; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","availability":"direct","bytes":644201,"sha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Power Products/Gladiator CFS Series Disconnects/CFS-2PCC30.dwg"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Power Products/Gladiator CFS Series Disconnects/CFS-2PCC30.dwg"},{"id":"cad-cfs-2pm30-dwg-6b82ff493b24cd","name":"cfsdisconnects.zip","format":"ZIP","purpose":"Contains CFS-2PM30.dwg; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","availability":"direct","bytes":644201,"sha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Power Products/Gladiator CFS Series Disconnects/CFS-2PM30.dwg"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Power Products/Gladiator CFS Series Disconnects/CFS-2PM30.dwg"}],"fileClasses":["mechanical CAD","dimensioned drawings"],"configurationNote":"The verified native member is Power Products/Gladiator CFS Series Disconnects/CFS-2PCC30.dwg. Its identity was checked against the acquired manufacturer archive. Coordinate the switch mounting, conductor approach and operator access with the enclosure arrangement. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: CFS-2PM30. Grouping does not establish electrical interchangeability.","drawingReference":{"family":"Gladiator CFS Series Disconnects","filenames":["CFS-2PCC30.dwg","CFS-2PM30.dwg"],"parentId":"ad-cfsdisconnects"},"equipmentFacts":[{"label":"Equipment / resource","value":"CFS-2PCC30 disconnecting switch"},{"label":"Manufacturer","value":"AutomationDirect"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Listed file formats","value":"DWG"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-10-13"},{"label":"Download access","value":"Use the official manufacturer source or request the exact drawing"}],"relatedReferences":[{"name":"AutomationDirect Gladiator CFS disconnects","url":"https://eloragrid.ai/objects/automationdirect-gladiator-cfs-disconnects"},{"name":"AutomationDirect CFS-2PCC30 disconnecting switch","url":"https://eloragrid.ai/objects/ga-cfs-2pcc30-808054d211f0"},{"name":"Switchgear panel","url":"https://eloragrid.ai/objects/switchgear-panel"},{"name":"Switchboard","url":"https://eloragrid.ai/objects/switchboard"},{"name":"Ring main unit","url":"https://eloragrid.ai/objects/ring-main-unit"}],"nativeFiles":[{"filename":"Power Products/Gladiator CFS Series Disconnects/CFS-2PCC30.dwg","format":"DWG","bytes":193369,"sha256":"fc3a3d3f176e09aa8c8857285d4d154bdfbee8dd756752ac24a8913612dee6d3","archiveSha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","sourceUrl":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","signature":"AC1015"},{"filename":"Power Products/Gladiator CFS Series Disconnects/CFS-2PM30.dwg","format":"DWG","bytes":193373,"sha256":"8b165ab422f73f6f07ba28d5638c7eb4716aff2b6d4f3adbccf6815eef167120","archiveSha256":"d4a824eec535548e1b3516b542563d17bd8c44f8d93aa4f1c097ea224442f4ae","sourceUrl":"https://ftp.automationdirect.com/support/drawings/cfsdisconnects.zip","signature":"AC1015"}],"fileChoiceGuidance":["The verified native member is Power Products/Gladiator CFS Series Disconnects/CFS-2PCC30.dwg. Its identity was checked against the acquired manufacturer archive. Coordinate the switch mounting, conductor approach and operator access with the enclosure arrangement. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: CFS-2PM30. Grouping does not establish electrical interchangeability."],"plainEnglish":{"title":"What the equipment does","introduction":"A disconnector separates equipment from its supply under its specified conditions. Whether it can also interrupt load current depends on the device's switching rating.","example":"In a switchyard, a disconnector provides an isolation point for a circuit section within the site's operating procedure.","drawings":"The verified native member is Power Products/Gladiator CFS Series Disconnects/CFS-2PCC30.dwg. Its identity was checked against the acquired manufacturer archive. Coordinate the switch mounting, conductor approach and operator access with the enclosure arrangement. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: CFS-2PM30. Grouping does not establish electrical interchangeability.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Find CFS-2PCC30 in the official archive","Open the matching original drawing","Coordinate disconnect interfaces"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"AutomationDirect official source","url":"https://support.automationdirect.com/docs/drawings.html"}],"profileId":"disconnect","checklist":["Confirm that the project schedule calls for CFS-2PCC30 or an explicitly documented associated drawing identity.","Coordinate the switch mounting, conductor approach and operator access with the enclosure arrangement.","Check the units and drawing revision before measuring or inserting geometry into a project.","Coordinate the mounting and connection faces with adjacent equipment, enclosure access and the cable route.","Verify ratings, compatible accessories and installation clearances using the manufacturer documentation for the exact device."],"questions":[{"question":"What does the CFS-2PCC30 reference verify?","answer":"It verifies the acquired native drawing identity and its place in the official Gladiator CFS disconnect hardware source collection. The source member and checksums identify the reviewed file; they do not establish the selected device rating or current revision."},{"question":"How should I use the original file?","answer":"Download the unchanged manufacturer archive from the official route and locate Power Products/Gladiator CFS Series Disconnects/CFS-2PCC30.dwg. Check the drawing units and revision before using its geometry in the project."},{"question":"Can grouped drawing identities replace one another electrically?","answer":"No. Mechanical drawing grouping only avoids separate pages for matching geometry, views or voltage aliases. Confirm exact electrical function, connection arrangement and manufacturer compatibility separately."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/drawing-cfs-2pcc30-808054d211f0"}