{"id":"drawing-fp-mp-10-60f98a014986","name":"FP_MP_10 enclosure mounting subpanel","manufacturer":"Hensel","category":"switchgear","description":"CAD drawings for FP_MP_10 help place the selected enclosure mounting subpanel and coordinate its mounting, connection access and service space. A mounting subpanel supports selected equipment inside an enclosure. Its usable mounting area, fixing interfaces and removal route are separate from the external enclosure outline.","equipment":["ENYSTAR enclosure and distribution-system STEP"],"keywords":["FP MP 10","ENYSTAR enclosure and distribution-system STEP","FP_MP_10.stp","FP_MP_10.stp","FP_MP_10 enclosure mounting subpanel","CAD drawings for FP_MP_10 help place the selected enclosure mounting subpanel and coordinate its mounting, connection access and service space. A mounting subpanel supports selected equipment inside an enclosure. Its usable mounting area, fixing interfaces and removal route are separate from the external enclosure outline."],"markets":["UK","Europe","Global"],"marketNote":"UK/European source discovery. Tags do not establish certification, country availability or suitability of every configuration.","kind":"drawing","sourceUrl":"https://www.hensel-electric.de/de-de/service/downloads/digitale-produktdaten/3d-step.php","officialEvidenceUrl":"https://www.hensel-electric.de/de-de/service/downloads/digitale-produktdaten/3d-step.php","sourcePublisher":"Hensel","formats":["STP"],"availability":"direct","accessNote":"Original CAD is retained privately; explicit publisher restrictions keep public downloads on the official route. Use Request CAD for exact variants.","checkedAt":"2026-10-14T00:00:00.000Z","files":[{"id":"reviewed-7df1d124522a288a29ed","name":"ENYSTAR_gesamt.ZIP","format":"ZIP","purpose":"Contains FP_MP_10.stp; download the original archive and locate the named member.","url":"https://www.hensel-electric.de/media/docs/allgemein/3d-step-dateien/ENYSTAR_gesamt.ZIP","availability":"direct","redistribution":"restricted","validation":"archive-inspected","bytes":14555589,"sha256":"121a049909039cf740e36fdefaffeeb50804718738ebbdc8430e7a9e42b2a836","retrievedAt":"2026-10-14T01:22:40.491255+00:00","archiveContents":["ENYSTAR_Montageplatten.zip!/ENYSTAR_Montageplatten/FP_MP_10.stp"],"rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://www.hensel-electric.de/en-en/impressum/"],"note":"Imprint requires written approval for reproduction, publication or transfer of website materials."},"archiveMember":"ENYSTAR_Montageplatten.zip!/ENYSTAR_Montageplatten/FP_MP_10.stp"},{"id":"reviewed-06496ac4c1bb0d01ece1","name":"ENYSTAR_Montageplatten.zip","format":"ZIP","purpose":"Contains FP_MP_10.stp; download the original archive and locate the named member.","url":"https://www.hensel-electric.de/media/docs/allgemein/3d-step-dateien/ENYSTAR_Montageplatten.zip","availability":"direct","redistribution":"restricted","validation":"archive-inspected","bytes":23421,"sha256":"a808cc9f25598d591c5e352cd07c5aaa109cdc8f43a56036d9c18d6d16b38c07","retrievedAt":"2026-10-14T01:16:36.905846+00:00","archiveContents":["ENYSTAR_Montageplatten/FP_MP_10.stp"],"rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://www.hensel-electric.de/en-en/impressum/"],"note":"Imprint requires written approval for reproduction, publication or transfer of website materials."},"archiveMember":"ENYSTAR_Montageplatten/FP_MP_10.stp"}],"fileClasses":["mechanical-layout","installation-outline"],"configurationNote":"The acquired source archive contains ENYSTAR_Montageplatten/FP_MP_10.stp, a 23,189-byte STP native file. Its file signature and SHA-256 were checked against the held original. The STEP file header was validated as an ISO 10303 exchange file. A mounting panel model does not establish the completed enclosure rating or the permitted equipment loading. Use the original drawing annotations and current installation instructions to confirm units, revision and service space. Additional verified grouped archive paths: ENYSTAR_Montageplatten.zip!/ENYSTAR_Montageplatten/FP_MP_10.stp. These paths retain their own archive and native checksums in the file evidence.","drawingReference":{"family":"ENYSTAR enclosure and distribution-system STEP","filenames":["FP_MP_10.stp"],"parentId":"europe-hensel-enystar"},"equipmentFacts":[{"label":"Equipment / resource","value":"FP_MP_10 enclosure mounting subpanel"},{"label":"Manufacturer","value":"Hensel"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Listed file formats","value":"STP"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-10-14"},{"label":"Download access","value":"Use the official manufacturer source or request the exact drawing"}],"relatedReferences":[{"name":"Hensel ENYSTAR distribution enclosures","url":"https://eloragrid.ai/objects/europe-hensel-enystar"},{"name":"Hensel FP_MP_10 enclosure mounting subpanel","url":"https://eloragrid.ai/objects/ga-fp-mp-10-60f98a014986"},{"name":"Switchgear panel","url":"https://eloragrid.ai/objects/switchgear-panel"},{"name":"Switchboard","url":"https://eloragrid.ai/objects/switchboard"},{"name":"Ring main unit","url":"https://eloragrid.ai/objects/ring-main-unit"}],"nativeFiles":[{"filename":"ENYSTAR_Montageplatten/FP_MP_10.stp","format":"STP","bytes":23189,"sha256":"7e70ffc4ede9ec239ef9b44e4bbf9ca785b9022f98565eb9825dc620752d0541","archiveSha256":"a808cc9f25598d591c5e352cd07c5aaa109cdc8f43a56036d9c18d6d16b38c07","sourceUrl":"https://www.hensel-electric.de/media/docs/allgemein/3d-step-dateien/ENYSTAR_Montageplatten.zip","signature":"ISO-10303-21"},{"filename":"ENYSTAR_Montageplatten.zip!/ENYSTAR_Montageplatten/FP_MP_10.stp","format":"STP","bytes":23189,"sha256":"7e70ffc4ede9ec239ef9b44e4bbf9ca785b9022f98565eb9825dc620752d0541","archiveSha256":"121a049909039cf740e36fdefaffeeb50804718738ebbdc8430e7a9e42b2a836","sourceUrl":"https://www.hensel-electric.de/media/docs/allgemein/3d-step-dateien/ENYSTAR_gesamt.ZIP","signature":"ISO-10303-21"}],"fileChoiceGuidance":["The acquired source archive contains ENYSTAR_Montageplatten/FP_MP_10.stp, a 23,189-byte STP native file. Its file signature and SHA-256 were checked against the held original. The STEP file header was validated as an ISO 10303 exchange file. A mounting panel model does not establish the completed enclosure rating or the permitted equipment loading. Use the original drawing annotations and current installation instructions to confirm units, revision and service space. Additional verified grouped archive paths: ENYSTAR_Montageplatten.zip!/ENYSTAR_Montageplatten/FP_MP_10.stp. These paths retain their own archive and native checksums in the file evidence."],"plainEnglish":{"title":"What the equipment does","introduction":"Mounting hardware holds equipment in its intended position. Rails, plates, adapters and supports each provide a particular attachment or support arrangement.","example":"In a switchroom control cabinet, a mounting plate and DIN rail can support terminals, relays and power supplies in an organised layout.","drawings":"The acquired source archive contains ENYSTAR_Montageplatten/FP_MP_10.stp, a 23,189-byte STP native file. Its file signature and SHA-256 were checked against the held original. The STEP file header was validated as an ISO 10303 exchange file. A mounting panel model does not establish the completed enclosure rating or the permitted equipment loading. Use the original drawing annotations and current installation instructions to confirm units, revision and service space. Additional verified grouped archive paths: ENYSTAR_Montageplatten.zip!/ENYSTAR_Montageplatten/FP_MP_10.stp. These paths retain their own archive and native checksums in the file evidence.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Find FP_MP_10 in the official archive","Open the matching original drawing","Coordinate distribution mounting plate interfaces"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Hensel official source","url":"https://www.hensel-electric.de/de-de/service/downloads/digitale-produktdaten/3d-step.php"}],"profileId":"mounting","checklist":["Confirm that FP_MP_10 is the intended drawing identity for the selected distribution mounting plate.","Check native drawing units and import scale before taking any dimensions.","Check the usable fixing area and all mounting offsets before arranging rails, terminals or power equipment.","Check the complete assembly and its current installation instructions, including any omitted hardware.","Retain the manufacturer drawing revision and the source archive identity with the project record."],"questions":[{"question":"What does the FP_MP_10 file identify?","answer":"It identifies the named distribution mounting plate drawing in the official ENYSTAR enclosure and distribution-system STEP archive. Its native member path and checksum are recorded below; this is stronger evidence than a search result or an inferred catalogue number."},{"question":"Does this drawing include the complete installation?","answer":"A mounting panel model does not establish the completed enclosure rating or the permitted equipment loading. Coordinate adjacent components, wiring and required working space separately."},{"question":"Which file should I use?","answer":"Download the official original archive and select the recorded native member. Follow publisher access terms; this page does not replace the current manufacturer drawing or grant redistribution rights."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/drawing-fp-mp-10-60f98a014986"}