{"id":"drawing-kn-d12led-24ac-e4ff87734f9e","name":"KN-D12LED-24AC double-level terminal block drawing","manufacturer":"AutomationDirect","category":"wiring","description":"Manufacturer drawings for KN-D12LED-24AC support double-level terminal block layout and mechanical-interface coordination. Check native drawing units and import scale before taking any dimensions. Use the named original drawing for mounting details and confirm the selected configuration in the current manufacturer documentation.","equipment":["Konnect-It DIN-Rail Terminal Blocks"],"keywords":["KN-D12LED-24AC","Konnect-It DIN-Rail Terminal Blocks","KN-D12LED-24AC.DWG","KN-D12LED-24AC double-level terminal block drawing","Manufacturer drawings for KN-D12LED-24AC support double-level terminal block layout and mechanical-interface coordination. Check native drawing units and import scale before taking any dimensions. Use the named original drawing for mounting details and confirm the selected configuration in the current manufacturer documentation."],"markets":["US","Global"],"marketNote":"US and Canada supplier catalogue; globally discoverable. Regional suitability must be verified for exact part.","kind":"drawing","sourceUrl":"https://support.automationdirect.com/docs/drawings.html","officialEvidenceUrl":"https://support.automationdirect.com/docs/drawings.html","sourcePublisher":"AutomationDirect","formats":["DWG"],"availability":"direct","accessNote":"Original CAD is retained privately; explicit publisher restrictions keep public downloads on the official route. Use Request CAD for exact variants.","checkedAt":"2026-10-13T00:00:00.000Z","files":[{"id":"cad-kn-d12led-24ac-dwg-879a23ac9b3981","name":"konnect.zip","format":"ZIP","purpose":"Contains KN-D12LED-24AC.DWG; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/konnect.zip","availability":"direct","bytes":12825068,"sha256":"5d4b2ce688541e422ba6f79b2def8dd7d6603e987a719b415641264c0275dc11","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Other PLC Products/Konnect-It/KN-D12LED-24AC.DWG"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Other PLC Products/Konnect-It/KN-D12LED-24AC.DWG"},{"id":"cad-kn-d12led-24dc-dwg-4d05b0c0b2f11a","name":"konnect.zip","format":"ZIP","purpose":"Contains KN-D12LED-24DC.DWG; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/konnect.zip","availability":"direct","bytes":12825068,"sha256":"5d4b2ce688541e422ba6f79b2def8dd7d6603e987a719b415641264c0275dc11","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Other PLC Products/Konnect-It/KN-D12LED-24DC.DWG"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Other PLC Products/Konnect-It/KN-D12LED-24DC.DWG"},{"id":"cad-kn-d12led-110ac-dwg-f730adaf677c8c","name":"konnect.zip","format":"ZIP","purpose":"Contains KN-D12LED-110AC.DWG; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/konnect.zip","availability":"direct","bytes":12825068,"sha256":"5d4b2ce688541e422ba6f79b2def8dd7d6603e987a719b415641264c0275dc11","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Other PLC Products/Konnect-It/KN-D12LED-110AC.DWG"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Other PLC Products/Konnect-It/KN-D12LED-110AC.DWG"},{"id":"cad-kn-d12led-110dc-dwg-7a0c5086ee7cff","name":"konnect.zip","format":"ZIP","purpose":"Contains KN-D12LED-110DC.DWG; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/konnect.zip","availability":"direct","bytes":12825068,"sha256":"5d4b2ce688541e422ba6f79b2def8dd7d6603e987a719b415641264c0275dc11","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Other PLC Products/Konnect-It/KN-D12LED-110DC.DWG"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Other PLC Products/Konnect-It/KN-D12LED-110DC.DWG"}],"fileClasses":["mechanical CAD","dimensioned drawings"],"configurationNote":"The acquired source archive contains Other PLC Products/Konnect-It/KN-D12LED-24AC.DWG, a 149,697-byte DWG native file. Its file signature and SHA-256 were checked against the held original. Native non-text geometry was also compared to identify repeated mechanical outlines. A terminal drawing does not establish the circuit connection or the current permitted for a complete terminal strip. Use the original drawing annotations and current installation instructions to confirm units, revision and service space.","drawingReference":{"family":"Konnect-It DIN-Rail Terminal Blocks","filenames":["KN-D12LED-24AC.DWG","KN-D12LED-24DC.DWG","KN-D12LED-110AC.DWG","KN-D12LED-110DC.DWG"],"parentId":"ad-konnect"},"equipmentFacts":[{"label":"Equipment / resource","value":"KN-D12LED-24AC double-level terminal block drawing"},{"label":"Manufacturer","value":"AutomationDirect"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Listed file formats","value":"DWG"},{"label":"Listed files","value":"4"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-10-13"},{"label":"Download access","value":"Use the official manufacturer source or request the exact drawing"}],"relatedReferences":[{"name":"AutomationDirect Konnect-It DIN-rail terminals","url":"https://eloragrid.ai/objects/automationdirect-konnect-it-din-rail-terminals"},{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"nativeFiles":[{"filename":"Other PLC Products/Konnect-It/KN-D12LED-24AC.DWG","format":"DWG","bytes":149697,"sha256":"1ab25348eec68b906d9f026f22148b226ea4aaade3c18b6af5b311980d858785","archiveSha256":"5d4b2ce688541e422ba6f79b2def8dd7d6603e987a719b415641264c0275dc11","sourceUrl":"https://ftp.automationdirect.com/support/drawings/konnect.zip","signature":"AC1015"},{"filename":"Other PLC Products/Konnect-It/KN-D12LED-24DC.DWG","format":"DWG","bytes":149699,"sha256":"6c38a45cd546ba4de8ef90c4d0c72ca557446455c96ae264874643f9a75bb2c0","archiveSha256":"5d4b2ce688541e422ba6f79b2def8dd7d6603e987a719b415641264c0275dc11","sourceUrl":"https://ftp.automationdirect.com/support/drawings/konnect.zip","signature":"AC1015"},{"filename":"Other PLC Products/Konnect-It/KN-D12LED-110AC.DWG","format":"DWG","bytes":149699,"sha256":"df299acc3dd0c3a0b2395c757f091920d9cca1e5231e6abce97f14da059fe60c","archiveSha256":"5d4b2ce688541e422ba6f79b2def8dd7d6603e987a719b415641264c0275dc11","sourceUrl":"https://ftp.automationdirect.com/support/drawings/konnect.zip","signature":"AC1015"},{"filename":"Other PLC Products/Konnect-It/KN-D12LED-110DC.DWG","format":"DWG","bytes":149698,"sha256":"22a17b29700a4fd982d3c59e603f61c533f310690bd3d2d3b9d578fd32bfcb8b","archiveSha256":"5d4b2ce688541e422ba6f79b2def8dd7d6603e987a719b415641264c0275dc11","sourceUrl":"https://ftp.automationdirect.com/support/drawings/konnect.zip","signature":"AC1015"}],"fileChoiceGuidance":["The acquired source archive contains Other PLC Products/Konnect-It/KN-D12LED-24AC.DWG, a 149,697-byte DWG native file. Its file signature and SHA-256 were checked against the held original. Native non-text geometry was also compared to identify repeated mechanical outlines. A terminal drawing does not establish the circuit connection or the current permitted for a complete terminal strip. Use the original drawing annotations and current installation instructions to confirm units, revision and service space."],"plainEnglish":{"title":"What the equipment does","introduction":"A terminal provides an identified point for joining wires to equipment or to other wires. Terminal strips organise those connections so they can be wired and checked.","example":"In a substation relay panel, numbered terminals connect the switchyard cables to the protection and control equipment.","drawings":"The acquired source archive contains Other PLC Products/Konnect-It/KN-D12LED-24AC.DWG, a 149,697-byte DWG native file. Its file signature and SHA-256 were checked against the held original. Native non-text geometry was also compared to identify repeated mechanical outlines. A terminal drawing does not establish the circuit connection or the current permitted for a complete terminal strip. Use the original drawing annotations and current installation instructions to confirm units, revision and service space.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Find KN-D12LED-24AC in the official archive","Open the matching original drawing","Coordinate double-level terminal block interfaces"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"AutomationDirect official source","url":"https://support.automationdirect.com/docs/drawings.html"}],"profileId":"terminal","checklist":["Confirm that KN-D12LED-24AC is the intended drawing identity for the selected double-level terminal block.","Check native drawing units and import scale before taking any dimensions.","Check conductor approach, screwdriver access and identification space before fixing the next device.","Check the complete assembly and its current installation instructions, including any omitted hardware.","Retain the manufacturer drawing revision and the source archive identity with the project record."],"questions":[{"question":"What does the KN-D12LED-24AC file identify?","answer":"It identifies the named double-level terminal block drawing in the official Konnect-It DIN-Rail Terminal Blocks archive. Its native member path and checksum are recorded below; this is stronger evidence than a search result or an inferred catalogue number."},{"question":"Does this drawing include the complete installation?","answer":"A terminal drawing does not establish the circuit connection or the current permitted for a complete terminal strip. Coordinate adjacent components, wiring and required working space separately."},{"question":"Which file should I use?","answer":"Download the official original archive and select the recorded native member. Follow publisher access terms; this page does not replace the current manufacturer drawing or grant redistribution rights."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/drawing-kn-d12led-24ac-e4ff87734f9e"}