# LR-11P0-1PH line reactor

CAD drawings for LR-11P0-1PH help place the selected line reactor and coordinate its mounting, connection access and service space. A line reactor is an inductive component used in the selected power circuit. A layout drawing describes its physical installation, while the electrical design establishes its required application and rating.

## Equipment and file summary

Equipment / resource: LR-11P0-1PH line reactor
Manufacturer: AutomationDirect
Resource type: Named drawing reference
Listed file formats: DWG
Listed files: 3
Available previews: Manufacturer source / drawing request
Recorded revisions: Confirm the revision with the manufacturer
Source checked: 2026-10-13
Download access: Use the official manufacturer source or request the exact drawing

## Related GA references

- [AutomationDirect LR-11P0-1PH line reactor](https://eloragrid.ai/objects/ga-lr-11p0-1ph-e26c4589e956)
- [Variable-frequency drive](https://eloragrid.ai/objects/ga-variable-frequency-drive)
- [AC line reactor](https://eloragrid.ai/objects/ga-ac-line-reactor)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/drawing-lr-11p0-1ph-e26c4589e956
Manufacturer: AutomationDirect
Entry type: Named drawing reference
Part number: Not specified — select exact configuration
Category: Power quality & drives
Formats: DWG
Market discovery: US / Global
Access: Direct download
Official source: https://support.automationdirect.com/docs/drawings.html
Manufacturer evidence: https://support.automationdirect.com/docs/drawings.html
Source checked: 2026-10-13T00:00:00.000Z

Original CAD is retained privately; explicit publisher restrictions keep public downloads on the official route. Use Request CAD for exact variants.
US and Canada supplier catalogue; globally discoverable. Regional suitability must be verified for exact part.
The verified native member is Drives-Motors-Motion/GS and Durapulse AC Drives/AC Line Reactors/LR-11P0-1PH.dwg. Its identity was checked against the acquired manufacturer archive. Check the mounting pattern and terminal approach against the support and cable route; establish electrical selection from the product documentation. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: LR-22P0-1PH, LR-23P0-1PH. Grouping does not establish electrical interchangeability.


## In plain English

### What the equipment does

An inductor stores energy in a magnetic field and resists rapid changes in current. A reactor is an inductor selected for a power-system job.

### A simple example

In a microgrid switchroom, a line reactor can help limit current changes at a motor-drive input.

### What the drawings help you do

The verified native member is Drives-Motors-Motion/GS and Durapulse AC Drives/AC Line Reactors/LR-11P0-1PH.dwg. Its identity was checked against the acquired manufacturer archive. Check the mounting pattern and terminal approach against the support and cable route; establish electrical selection from the product documentation. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: LR-22P0-1PH, LR-23P0-1PH. Grouping does not establish electrical interchangeability.

### Before using this reference

- Confirm that the project schedule calls for LR-11P0-1PH or an explicitly documented associated drawing identity.
- Check the mounting pattern and terminal approach against the support and cable route; establish electrical selection from the product documentation.
- Check the units and drawing revision before measuring or inserting geometry into a project.
- Coordinate the mounting and connection faces with adjacent equipment, enclosure access and the cable route.
- Verify ratings, compatible accessories and installation clearances using the manufacturer documentation for the exact device.

### What does the LR-11P0-1PH reference verify?

It verifies the acquired native drawing identity and its place in the official AC line-reactor hardware source collection. The source member and checksums identify the reviewed file; they do not establish the selected device rating or current revision.

### How should I use the original file?

Download the unchanged manufacturer archive from the official route and locate Drives-Motors-Motion/GS and Durapulse AC Drives/AC Line Reactors/LR-11P0-1PH.dwg. Check the drawing units and revision before using its geometry in the project.

### Can grouped drawing identities replace one another electrically?

No. Mechanical drawing grouping only avoids separate pages for matching geometry, views or voltage aliases. Confirm exact electrical function, connection arrangement and manufacturer compatibility separately.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Find LR-11P0-1PH in the official archive → Open the matching original drawing → Coordinate line-reactor interfaces
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [AutomationDirect official source](https://support.automationdirect.com/docs/drawings.html)


## Which file should I choose?

The verified native member is Drives-Motors-Motion/GS and Durapulse AC Drives/AC Line Reactors/LR-11P0-1PH.dwg. Its identity was checked against the acquired manufacturer archive. Check the mounting pattern and terminal approach against the support and cable route; establish electrical selection from the product documentation. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: LR-22P0-1PH, LR-23P0-1PH. Grouping does not establish electrical interchangeability.

## Official files

- ac_linereactors.zip (ZIP): https://ftp.automationdirect.com/support/drawings/ac_linereactors.zip
  Site download: not publicly hosted
  Rights review: The drawing page limits the documents to exclusive use by AutomationDirect customers.; evidence: https://support.automationdirect.com/docs/drawings.html
  Purpose: Contains LR-11P0-1PH.dwg; download the original archive and locate the named member.; acquired: true; redistribution: restricted; SHA-256: 497f09da39e7b0d1621a9c66339a497adbdfbb2ecaf123a8df172efea1091a2c; revision: not recorded
  - Drives-Motors-Motion/GS and Durapulse AC Drives/AC Line Reactors/LR-11P0-1PH.dwg
- ac_linereactors.zip (ZIP): https://ftp.automationdirect.com/support/drawings/ac_linereactors.zip
  Site download: not publicly hosted
  Rights review: The drawing page limits the documents to exclusive use by AutomationDirect customers.; evidence: https://support.automationdirect.com/docs/drawings.html
  Purpose: Contains LR-22P0-1PH.dwg; download the original archive and locate the named member.; acquired: true; redistribution: restricted; SHA-256: 497f09da39e7b0d1621a9c66339a497adbdfbb2ecaf123a8df172efea1091a2c; revision: not recorded
  - Drives-Motors-Motion/GS and Durapulse AC Drives/AC Line Reactors/LR-22P0-1PH.dwg
- ac_linereactors.zip (ZIP): https://ftp.automationdirect.com/support/drawings/ac_linereactors.zip
  Site download: not publicly hosted
  Rights review: The drawing page limits the documents to exclusive use by AutomationDirect customers.; evidence: https://support.automationdirect.com/docs/drawings.html
  Purpose: Contains LR-23P0-1PH.dwg; download the original archive and locate the named member.; acquired: true; redistribution: restricted; SHA-256: 497f09da39e7b0d1621a9c66339a497adbdfbb2ecaf123a8df172efea1091a2c; revision: not recorded
  - Drives-Motors-Motion/GS and Durapulse AC Drives/AC Line Reactors/LR-23P0-1PH.dwg