{"id":"drawing-p3-32nd3-eec066be2579","name":"P3-32ND3 digital input module","manufacturer":"AutomationDirect","category":"automation","description":"CAD drawings for P3-32ND3 help place the selected digital input module and coordinate its mounting, connection access and service space. A digital input module reports discrete conditions such as a switch being open or closed. The selected wiring and electrical data establish how each input is supplied and referenced.","equipment":["Productivity3000 PAC"],"keywords":["P3-32ND3","Productivity3000 PAC","P3-32ND3.dwg","P3-32ND3 digital input module","CAD drawings for P3-32ND3 help place the selected digital input module and coordinate its mounting, connection access and service space. A digital input module reports discrete conditions such as a switch being open or closed. The selected wiring and electrical data establish how each input is supplied and referenced."],"markets":["US","Global"],"marketNote":"US and Canada supplier catalogue; globally discoverable. Regional suitability must be verified for exact part.","kind":"drawing","sourceUrl":"https://support.automationdirect.com/docs/drawings.html","officialEvidenceUrl":"https://support.automationdirect.com/docs/drawings.html","sourcePublisher":"AutomationDirect","formats":["DWG"],"availability":"direct","accessNote":"Original CAD is retained privately; explicit publisher restrictions keep public downloads on the official route. Use Request CAD for exact variants.","checkedAt":"2026-10-13T00:00:00.000Z","files":[{"id":"cad-p3-32nd3-dwg-16c96b66bf435f","name":"p3000pac.zip","format":"ZIP","purpose":"Contains P3-32ND3.dwg; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/p3000pac.zip","availability":"direct","bytes":7097670,"sha256":"ed6f7b177d85ad16fa26931a04cb0fa487077db158f6de9bf92751562b71a010","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["PLC Families/P3000/P3-32ND3.dwg"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"PLC Families/P3000/P3-32ND3.dwg"},{"id":"cad-p3-32td1-dwg-b57583e8467577","name":"p3000pac.zip","format":"ZIP","purpose":"Contains P3-32TD1.dwg; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/p3000pac.zip","availability":"direct","bytes":7097670,"sha256":"ed6f7b177d85ad16fa26931a04cb0fa487077db158f6de9bf92751562b71a010","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["PLC Families/P3000/P3-32TD1.dwg"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"PLC Families/P3000/P3-32TD1.dwg"},{"id":"cad-p3-32td2-dwg-d29b1ddcde7c3f","name":"p3000pac.zip","format":"ZIP","purpose":"Contains P3-32TD2.dwg; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/p3000pac.zip","availability":"direct","bytes":7097670,"sha256":"ed6f7b177d85ad16fa26931a04cb0fa487077db158f6de9bf92751562b71a010","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["PLC Families/P3000/P3-32TD2.dwg"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"PLC Families/P3000/P3-32TD2.dwg"}],"fileClasses":["mechanical CAD","dimensioned drawings"],"configurationNote":"The verified native member is PLC Families/P3000/P3-32ND3.dwg. Its identity was checked against the acquired manufacturer archive. Locate the station and its connection faces before routing conductors; maintain access to the removable or serviceable parts shown in the drawing. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: P3-32TD1, P3-32TD2. Grouping does not establish electrical interchangeability.","drawingReference":{"family":"Productivity3000 PAC","filenames":["P3-32ND3.dwg","P3-32TD1.dwg","P3-32TD2.dwg"],"parentId":"ad-p3000pac"},"equipmentFacts":[{"label":"Equipment / resource","value":"P3-32ND3 digital input module"},{"label":"Manufacturer","value":"AutomationDirect"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Listed file formats","value":"DWG"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-10-13"},{"label":"Download access","value":"Use the official manufacturer source or request the exact drawing"}],"relatedReferences":[{"name":"AutomationDirect Productivity3000 PAC","url":"https://eloragrid.ai/objects/automationdirect-productivity3000-pac"},{"name":"AutomationDirect P3-32ND3 digital input module","url":"https://eloragrid.ai/objects/ga-p3-32nd3-eec066be2579"},{"name":"PLC CPU module","url":"https://eloragrid.ai/objects/ga-plc-cpu-module"},{"name":"HMI touchscreen","url":"https://eloragrid.ai/objects/ga-hmi-touchscreen"}],"nativeFiles":[{"filename":"PLC Families/P3000/P3-32ND3.dwg","format":"DWG","bytes":259560,"sha256":"eb2877da8ec919c9e1279271c9c3af2eb74f534d131758985cd000fa6cc61d11","archiveSha256":"ed6f7b177d85ad16fa26931a04cb0fa487077db158f6de9bf92751562b71a010","sourceUrl":"https://ftp.automationdirect.com/support/drawings/p3000pac.zip","signature":"AC1015"},{"filename":"PLC Families/P3000/P3-32TD1.dwg","format":"DWG","bytes":259556,"sha256":"cbe71bd96b1a2db57343ba901ffaa13d91d128f736ff4e80d9448e6bb5849ed1","archiveSha256":"ed6f7b177d85ad16fa26931a04cb0fa487077db158f6de9bf92751562b71a010","sourceUrl":"https://ftp.automationdirect.com/support/drawings/p3000pac.zip","signature":"AC1015"},{"filename":"PLC Families/P3000/P3-32TD2.dwg","format":"DWG","bytes":259558,"sha256":"2b9b0b87a9f43be097b1a590c595d44dc79056e8ae60282154634f576abe9216","archiveSha256":"ed6f7b177d85ad16fa26931a04cb0fa487077db158f6de9bf92751562b71a010","sourceUrl":"https://ftp.automationdirect.com/support/drawings/p3000pac.zip","signature":"AC1015"}],"fileChoiceGuidance":["The verified native member is PLC Families/P3000/P3-32ND3.dwg. Its identity was checked against the acquired manufacturer archive. Locate the station and its connection faces before routing conductors; maintain access to the removable or serviceable parts shown in the drawing. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: P3-32TD1, P3-32TD2. Grouping does not establish electrical interchangeability."],"plainEnglish":{"title":"What the equipment does","introduction":"An input module brings measurements or on/off signals from equipment into a controller so its program can respond.","example":"In a substation control panel, an input module can report whether a breaker is open or closed.","drawings":"The verified native member is PLC Families/P3000/P3-32ND3.dwg. Its identity was checked against the acquired manufacturer archive. Locate the station and its connection faces before routing conductors; maintain access to the removable or serviceable parts shown in the drawing. The drawing is a mechanical coordination reference, not a circuit design or certification record. Associated drawing identities with matching non-text geometry or explicit voltage/view aliases are grouped here: P3-32TD1, P3-32TD2. Grouping does not establish electrical interchangeability.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Find P3-32ND3 in the official archive","Open the matching original drawing","Coordinate plc-io interfaces"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"AutomationDirect official source","url":"https://support.automationdirect.com/docs/drawings.html"}],"profileId":"plc-input","checklist":["Confirm that the project schedule calls for P3-32ND3 or an explicitly documented associated drawing identity.","Locate the station and its connection faces before routing conductors; maintain access to the removable or serviceable parts shown in the drawing.","Check the units and drawing revision before measuring or inserting geometry into a project.","Map the shown hardware to the intended station position, terminal approach and control drawing; reserve access to ports and removable terminals.","Verify ratings, compatible accessories and installation clearances using the manufacturer documentation for the exact device."],"questions":[{"question":"What does the P3-32ND3 reference verify?","answer":"It verifies the acquired native drawing identity and its place in the official Productivity3000 PAC hardware source collection. The source member and checksums identify the reviewed file; they do not establish the selected device rating or current revision."},{"question":"How should I use the original file?","answer":"Download the unchanged manufacturer archive from the official route and locate PLC Families/P3000/P3-32ND3.dwg. Check the drawing units and revision before using its geometry in the project."},{"question":"Can grouped drawing identities replace one another electrically?","answer":"No. Mechanical drawing grouping only avoids separate pages for matching geometry, views or voltage aliases. Confirm exact electrical function, connection arrangement and manufacturer compatibility separately."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/drawing-p3-32nd3-eec066be2579"}