{"id":"drawing-px-302-c56f808fa3cd","name":"PX-302 analogue input module","manufacturer":"AutomationDirect","category":"automation","description":"CAD drawings for PX-302 help place the selected analogue input module and coordinate its mounting, connection access and service space. An analogue input module brings continuously varying sensor information into a controller. Its physical connectors and mounting arrangement are different questions from the signal range configured in the control program.","equipment":["Protos X Field I/O"],"keywords":["PX-302","Protos X Field I/O","PX-302.dwg","PX-302 analogue input module","CAD drawings for PX-302 help place the selected analogue input module and coordinate its mounting, connection access and service space. An analogue input module brings continuously varying sensor information into a controller. Its physical connectors and mounting arrangement are different questions from the signal range configured in the control program."],"markets":["US","Global"],"marketNote":"US and Canada supplier catalogue; globally discoverable. Regional suitability must be verified for exact part.","kind":"drawing","sourceUrl":"https://support.automationdirect.com/docs/drawings.html","officialEvidenceUrl":"https://support.automationdirect.com/docs/drawings.html","sourcePublisher":"AutomationDirect","formats":["DWG"],"availability":"direct","accessNote":"Original CAD is retained privately; explicit publisher restrictions keep public downloads on the official route. Use Request CAD for exact variants.","checkedAt":"2026-10-13T00:00:00.000Z","files":[{"id":"cad-px-302-dwg-8432adf840ee26","name":"pxio.zip","format":"ZIP","purpose":"Contains PX-302.dwg; download the original archive and locate the named member.","url":"https://ftp.automationdirect.com/support/drawings/pxio.zip","availability":"direct","bytes":2286206,"sha256":"ecfac391a72e937ec5e91a111454d6f36c1427e88d7b1c345c9de8c0315f040f","retrievedAt":"2026-10-13T05:24:41.677487+00:00","archiveContents":["Other PLC Products/Protos X IO/PX-302.dwg"],"validation":"archive-inspected","redistribution":"restricted","rightsReview":{"checkedAt":"2026-10-14T02:47:39.871680+00:00","sources":["https://support.automationdirect.com/docs/drawings.html"],"note":"The drawing page limits the documents to exclusive use by AutomationDirect customers."},"archiveMember":"Other PLC Products/Protos X IO/PX-302.dwg"}],"fileClasses":["mechanical CAD","dimensioned drawings"],"configurationNote":"The verified native member is Other PLC Products/Protos X IO/PX-302.dwg. Its identity was checked against the acquired manufacturer archive. Coordinate the field-I/O assembly and its cable approach, then map the selected hardware to the control drawing. The drawing is a mechanical coordination reference, not a circuit design or certification record.","drawingReference":{"family":"Protos X Field I/O","filenames":["PX-302.dwg"],"parentId":"ad-pxio"},"equipmentFacts":[{"label":"Equipment / resource","value":"PX-302 analogue input module"},{"label":"Manufacturer","value":"AutomationDirect"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Listed file formats","value":"DWG"},{"label":"Listed files","value":"1"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-10-13"},{"label":"Download access","value":"Use the official manufacturer source or request the exact drawing"}],"relatedReferences":[{"name":"AutomationDirect Protos X Field I/O","url":"https://eloragrid.ai/objects/automationdirect-protos-x-field-i-o"},{"name":"AutomationDirect PX-302 analogue input module","url":"https://eloragrid.ai/objects/ga-px-302-c56f808fa3cd"},{"name":"PLC CPU module","url":"https://eloragrid.ai/objects/ga-plc-cpu-module"},{"name":"HMI touchscreen","url":"https://eloragrid.ai/objects/ga-hmi-touchscreen"}],"nativeFiles":[{"filename":"Other PLC Products/Protos X IO/PX-302.dwg","format":"DWG","bytes":233255,"sha256":"80914c0e389325803ed9b9b9d51071df308a0a794d3c3dd47be06f0430e370c4","archiveSha256":"ecfac391a72e937ec5e91a111454d6f36c1427e88d7b1c345c9de8c0315f040f","sourceUrl":"https://ftp.automationdirect.com/support/drawings/pxio.zip","signature":"AC1015"}],"fileChoiceGuidance":["The verified native member is Other PLC Products/Protos X IO/PX-302.dwg. Its identity was checked against the acquired manufacturer archive. Coordinate the field-I/O assembly and its cable approach, then map the selected hardware to the control drawing. The drawing is a mechanical coordination reference, not a circuit design or certification record."],"plainEnglish":{"title":"What the equipment does","introduction":"An analogue input module measures changing signals, such as a sensor voltage or current, and gives the controller a numerical reading.","example":"In a microgrid control panel, it can read a temperature transmitter and report how hot the generator cooling system is.","drawings":"The verified native member is Other PLC Products/Protos X IO/PX-302.dwg. Its identity was checked against the acquired manufacturer archive. Coordinate the field-I/O assembly and its cable approach, then map the selected hardware to the control drawing. The drawing is a mechanical coordination reference, not a circuit design or certification record.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Find PX-302 in the official archive","Open the matching original drawing","Coordinate plc-io interfaces"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"AutomationDirect official source","url":"https://support.automationdirect.com/docs/drawings.html"}],"profileId":"analogue-input","checklist":["Confirm that the project schedule calls for PX-302 or an explicitly documented associated drawing identity.","Coordinate the field-I/O assembly and its cable approach, then map the selected hardware to the control drawing.","Check the units and drawing revision before measuring or inserting geometry into a project.","Map the shown hardware to the intended station position, terminal approach and control drawing; reserve access to ports and removable terminals.","Verify ratings, compatible accessories and installation clearances using the manufacturer documentation for the exact device."],"questions":[{"question":"What does the PX-302 reference verify?","answer":"It verifies the acquired native drawing identity and its place in the official Protos X field-I/O hardware source collection. The source member and checksums identify the reviewed file; they do not establish the selected device rating or current revision."},{"question":"How should I use the original file?","answer":"Download the unchanged manufacturer archive from the official route and locate Other PLC Products/Protos X IO/PX-302.dwg. Check the drawing units and revision before using its geometry in the project."},{"question":"Can grouped drawing identities replace one another electrically?","answer":"No. Mechanical drawing grouping only avoids separate pages for matching geometry, views or voltage aliases. Confirm exact electrical function, connection arrangement and manufacturer compatibility separately."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/drawing-px-302-c56f808fa3cd"}