# T1K-08TD1 digital output module

CAD drawings for T1K-08TD1 help place the selected digital output module and coordinate its mounting, connection access and service space. A digital output module sends discrete commands to connected control equipment. An output module is different from the power switching apparatus that may ultimately operate a motor.

## Equipment and file summary

Equipment / resource: T1K-08TD1 digital output module
Manufacturer: AutomationDirect
Resource type: Named drawing reference
Listed file formats: DWG
Listed files: 1
Available previews: Manufacturer source / drawing request
Recorded revisions: Confirm the revision with the manufacturer
Source checked: 2026-10-13
Download access: Use the official manufacturer source or request the exact drawing

## Related GA references

- [AutomationDirect Terminator Field I/O](https://eloragrid.ai/objects/automationdirect-terminator-field-i-o)
- [AutomationDirect T1K-08TD1 digital output module](https://eloragrid.ai/objects/ga-t1k-08td1-9cb967b60cc2)
- [PLC CPU module](https://eloragrid.ai/objects/ga-plc-cpu-module)
- [HMI touchscreen](https://eloragrid.ai/objects/ga-hmi-touchscreen)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/drawing-t1k-08td1-9cb967b60cc2
Manufacturer: AutomationDirect
Entry type: Named drawing reference
Part number: Not specified — select exact configuration
Category: Automation & controls
Formats: DWG
Market discovery: US / Global
Access: Direct download
Official source: https://support.automationdirect.com/docs/drawings.html
Manufacturer evidence: https://support.automationdirect.com/docs/drawings.html
Source checked: 2026-10-13T00:00:00.000Z

Original CAD is retained privately; explicit publisher restrictions keep public downloads on the official route. Use Request CAD for exact variants.
US and Canada supplier catalogue; globally discoverable. Regional suitability must be verified for exact part.
The verified native member is Other PLC Products/Terminator Field IO/T1K-08TD1.dwg. Its identity was checked against the acquired manufacturer archive. Use the device outline to coordinate the I/O station, its terminals and the service access needed beside cable duct. The drawing is a mechanical coordination reference, not a circuit design or certification record.


## In plain English

### What the equipment does

An output module passes a controller's commands to connected equipment through the type of electrical output provided.

### A simple example

In a switchroom ventilation panel, an output can request a contactor to start a fan.

### What the drawings help you do

The verified native member is Other PLC Products/Terminator Field IO/T1K-08TD1.dwg. Its identity was checked against the acquired manufacturer archive. Use the device outline to coordinate the I/O station, its terminals and the service access needed beside cable duct. The drawing is a mechanical coordination reference, not a circuit design or certification record.

### Before using this reference

- Confirm that the project schedule calls for T1K-08TD1 or an explicitly documented associated drawing identity.
- Use the device outline to coordinate the I/O station, its terminals and the service access needed beside cable duct.
- Check the units and drawing revision before measuring or inserting geometry into a project.
- Map the shown hardware to the intended station position, terminal approach and control drawing; reserve access to ports and removable terminals.
- Verify ratings, compatible accessories and installation clearances using the manufacturer documentation for the exact device.

### What does the T1K-08TD1 reference verify?

It verifies the acquired native drawing identity and its place in the official Terminator field-I/O hardware source collection. The source member and checksums identify the reviewed file; they do not establish the selected device rating or current revision.

### How should I use the original file?

Download the unchanged manufacturer archive from the official route and locate Other PLC Products/Terminator Field IO/T1K-08TD1.dwg. Check the drawing units and revision before using its geometry in the project.

### Can grouped drawing identities replace one another electrically?

No. Mechanical drawing grouping only avoids separate pages for matching geometry, views or voltage aliases. Confirm exact electrical function, connection arrangement and manufacturer compatibility separately.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Find T1K-08TD1 in the official archive → Open the matching original drawing → Coordinate plc-io interfaces
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [AutomationDirect official source](https://support.automationdirect.com/docs/drawings.html)


## Which file should I choose?

The verified native member is Other PLC Products/Terminator Field IO/T1K-08TD1.dwg. Its identity was checked against the acquired manufacturer archive. Use the device outline to coordinate the I/O station, its terminals and the service access needed beside cable duct. The drawing is a mechanical coordination reference, not a circuit design or certification record.

## Official files

- tio.zip (ZIP): https://ftp.automationdirect.com/support/drawings/tio.zip
  Site download: not publicly hosted
  Rights review: The drawing page limits the documents to exclusive use by AutomationDirect customers.; evidence: https://support.automationdirect.com/docs/drawings.html
  Purpose: Contains T1K-08TD1.dwg; download the original archive and locate the named member.; acquired: true; redistribution: restricted; SHA-256: 9ae4da496d59934a7f46e262100ffe1d1704f4e0c1f69d2341d289966bb4b007; revision: not recorded
  - Other PLC Products/Terminator Field IO/T1K-08TD1.dwg

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.