# ZEB32-45/KK — Overload relay, Separate mounting, Earth-fault protection: none, Ir= 9 - 45 A, 1 N/O, 1 N/C

Eaton ZEB32-45/KK — Overload relay, Separate mounting, Earth-fault protection: none, Ir= 9 - 45 A, 1 N/O, 1 N/C. Manufacturer CAD files for protection equipment selection and layout, identified by article 136497.

## Equipment and file summary

Equipment / resource: ZEB32-45/KK — Overload relay, Separate mounting, Earth-fault protection: none, Ir= 9 - 45 A, 1 N/O, 1 N/C
Manufacturer: Eaton
Resource type: Product
Part number: 136497
Manufacturer reference: 136497
Manufacturer type: ZEB32-45/KK
Available native formats: DWG / STEP
Listed file formats: DWG, STEP
Listed files: 2
Available previews: 1 drawing previews
Recorded revisions: Confirm the revision with the manufacturer
Source checked: 2026-11-17
Download access: Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply.

## Related GA references

- [Protection relay IED](https://eloragrid.ai/objects/ga-protection-relay-ied)
- [Power quality meter](https://eloragrid.ai/objects/ga-power-quality-meter)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/eaton-article-136497
Manufacturer: Eaton
Entry type: Product
Part number: 136497
Category: Protection & metering
Formats: DWG, STEP
Market discovery: Global
Access: Direct download
Official source: https://ecat.eaton.com/downloads/6a1b9504-69d4-4c90-9984-892fc90d2b2f/cad_files_001.zip
Manufacturer evidence: https://ecat.eaton.com/downloads/6a1b9504-69d4-4c90-9984-892fc90d2b2f/cad_files_001.zip
Source checked: 2026-11-17T15:50:41.709187+00:00

Download the retained manufacturer CAD originals from this library. ZIP packages contain the unchanged named native CAD file; manufacturer archive provenance is retained separately.
Confirm regional configuration, ratings and approvals with the manufacturer.
Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.


## In plain English

### What the equipment does

Overload protection responds when a motor is carrying excessive current for too long or heating beyond its configured limit. It can request that the motor is stopped.

### A simple example

In a switchroom ventilation starter, it can stop a fan motor that is overloaded rather than allowing it to keep overheating.

### What the drawings help you do

Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Motor current or temperature → Overload assessment → Motor stop request
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [Eaton official source](https://ecat.eaton.com/downloads/6a1b9504-69d4-4c90-9984-892fc90d2b2f/cad_files_001.zip)


## Which file should I choose?

Start with 136497. The files above belong to Eaton's ZEB32-45/KK — Overload relay, Separate mounting, Earth-fault protection: none, Ir= 9 - 45 A, 1 N/O, 1 N/C resource; match any model or option suffix in the filename to your selected unit.
Available here: STEP, DWG. The individual filenames above distinguish the supplied variants.

## Official files

- zeb32_kk.stp (STEP): https://ecat.eaton.com/downloads/6a1b9504-69d4-4c90-9984-892fc90d2b2f/cad_files_001.zip
  Download access: public; public_original
  Site download: https://eloragrid.ai/tools/cad-library/download/eaton-article-136497/native-fd206f23b4ffa8e6c2f35dc3-step
  Hosting basis: no-explicit-prohibition; publisher attribution: Eaton; reviewed: 2026-11-18T05:37:13.981462+00:00
  Rights review: Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed.; evidence: https://ecat.eaton.com/downloads/6a1b9504-69d4-4c90-9984-892fc90d2b2f/cad_files_001.zip, https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf, https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html
  Purpose: Manufacturer STEP CAD file; acquired: true; redistribution: unknown; SHA-256: fd206f23b4ffa8e6c2f35dc3005b2378f5f781591fea1811295578bc6452f39f; revision: not recorded
- eaton-electronic-overload-relays-mcad-drawings-zeb32-kk.dwg (DWG): https://ecat.eaton.com/downloads/6a1b9504-69d4-4c90-9984-892fc90d2b2f/cad_files_001.zip
  Download access: public; public_original
  Site download: https://eloragrid.ai/tools/cad-library/download/eaton-article-136497/native-c4d1996f05d1c8917bc0bcab-dwg
  Hosting basis: no-explicit-prohibition; publisher attribution: Eaton; reviewed: 2026-11-18T05:37:13.981462+00:00
  Rights review: Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed.; evidence: https://ecat.eaton.com/downloads/6a1b9504-69d4-4c90-9984-892fc90d2b2f/cad_files_001.zip, https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf, https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html
  Purpose: Manufacturer DWG CAD file; acquired: true; redistribution: unknown; SHA-256: c4d1996f05d1c8917bc0bcaba4914fc63de8cc6cf7caa2d82f41783f4c3d2c33; revision: not recorded

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.