{"id":"eaton-article-170351","name":"FRCMM-100/4/05-A — Residual current circuit breaker (RCCB), 100A, 4p, 500mA, type A","manufacturer":"Eaton","category":"breakers","description":"Eaton FRCMM-100/4/05-A — Residual current circuit breaker (RCCB), 100A, 4p, 500mA, type A. Manufacturer CAD files for breakers equipment selection and layout, identified by article 170351.","equipment":["breakers","FRCMM-100/4/05-A — Residual current circuit breaker (RCCB), 100A, 4p, 500mA, type A"],"keywords":["Eaton","FRCMM-100/4/05-A — Residual current circuit breaker (RCCB), 100A, 4p, 500mA, type A","170351","breakers","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"170351","sourceUrl":"https://ecat.eaton.com/downloads/c76fcb77-d19b-4c58-a764-7912052b6065/cad_files_001.zip","officialEvidenceUrl":"https://ecat.eaton.com/downloads/c76fcb77-d19b-4c58-a764-7912052b6065/cad_files_001.zip","sourcePublisher":"Eaton","formats":["STEP"],"availability":"direct","accessNote":"Download the retained manufacturer CAD originals from this library. ZIP packages contain the unchanged named native CAD file; manufacturer archive provenance is retained separately.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"170351","sourceUrl":"https://ecat.eaton.com/downloads/c76fcb77-d19b-4c58-a764-7912052b6065/cad_files_001.zip"},{"label":"Manufacturer type","value":"FRCMM-100/4/05-A","sourceUrl":"https://ecat.eaton.com/downloads/c76fcb77-d19b-4c58-a764-7912052b6065/cad_files_001.zip"},{"label":"Available native formats","value":"STEP","sourceUrl":"https://ecat.eaton.com/downloads/c76fcb77-d19b-4c58-a764-7912052b6065/cad_files_001.zip"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-fb8954f483ee22cb8246d358-step","name":"eaton-residual-current-circuit-breakers-3d-models-frcmm-4p.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://ecat.eaton.com/downloads/c76fcb77-d19b-4c58-a764-7912052b6065/cad_files_001.zip","availability":"direct","sha256":"fb8954f483ee22cb8246d35880ea2c29379bf6a136337494de933287a5626457","bytes":648629,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"eaton-residual-current-circuit-breakers-3d-models-frcmm-4p.stp.zip","format":"ZIP","sha256":"ae44bc15279c97dce83d5db18ae10a05c972f34b7d65cb761d2d11356b7691b3","bytes":110777,"includes":["eaton-residual-current-circuit-breakers-3d-models-frcmm-4p.stp"]},"rightsReview":{"checkedAt":"2026-11-18T05:37:13.981462+00:00","sources":["https://ecat.eaton.com/downloads/c76fcb77-d19b-4c58-a764-7912052b6065/cad_files_001.zip","https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html"],"note":"Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T05:05:58.495621+00:00","sourceArchive":{"url":"https://ecat.eaton.com/downloads/c76fcb77-d19b-4c58-a764-7912052b6065/cad_files_001.zip","sha256":"f2beb062d267eb9050b7444df32a838509450178ccc5ab70c2f626fdb01d2392","member":"eaton-residual-current-circuit-breakers-3d-models-frcmm-4p.stp","publisherMemberChecksumVerified":true},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T05:37:13.981462+00:00","evidenceUrl":"https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","attribution":"Eaton"},"previewGroup":"eaton-article-170351","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/eaton-article-170351/native-fb8954f483ee22cb8246d358-step"}],"artifacts":[{"id":"native-fb8954f483ee22cb8246d358-step","name":"eaton-residual-current-circuit-breakers-3d-models-frcmm-4p.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://ecat.eaton.com/downloads/c76fcb77-d19b-4c58-a764-7912052b6065/cad_files_001.zip","sourceSha256":"fb8954f483ee22cb8246d35880ea2c29379bf6a136337494de933287a5626457","artifactSha256":"ae44bc15279c97dce83d5db18ae10a05c972f34b7d65cb761d2d11356b7691b3","bytes":110777,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/eaton-article-170351/native-fb8954f483ee22cb8246d358-step","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"FRCMM-100/4/05-A — Residual current circuit breaker (RCCB), 100A, 4p, 500mA, type A"},{"label":"Manufacturer","value":"Eaton"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"170351"},{"label":"Manufacturer reference","value":"170351"},{"label":"Manufacturer type","value":"FRCMM-100/4/05-A"},{"label":"Available native formats","value":"STEP"},{"label":"Listed file formats","value":"STEP"},{"label":"Listed files","value":"1"},{"label":"Available previews","value":"No browser preview; original files are downloadable"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"relatedReferences":[{"name":"Air circuit breaker","url":"https://eloragrid.ai/objects/ga-air-circuit-breaker"},{"name":"Moulded-case circuit breaker","url":"https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker"}],"fileChoiceGuidance":["Start with 170351. The files above belong to Eaton's FRCMM-100/4/05-A — Residual current circuit breaker (RCCB), 100A, 4p, 500mA, type A resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP. The original filename is eaton-residual-current-circuit-breakers-3d-models-frcmm-4p.stp."],"plainEnglish":{"title":"What the equipment does","introduction":"A residual-current device compares the current leaving a circuit with the current returning. A difference can indicate current flowing along an unintended path, causing the device to trip. An RCBO also provides overcurrent protection.","example":"In a substation services board, it can protect a suitable maintenance-outlet circuit by detecting a current imbalance.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Outgoing and returning current","Difference is checked","Circuit disconnects if it trips"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Eaton official source","url":"https://ecat.eaton.com/downloads/c76fcb77-d19b-4c58-a764-7912052b6065/cad_files_001.zip"}],"profileId":"rccb"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/eaton-article-170351"}