{"id":"eaton-article-171188","name":"FRCMM-125/4/003-G/B — Residual current circuit-breaker, all-current sensitive, 125 A, 4p, 30 mA, type G/B","manufacturer":"Eaton","category":"breakers","description":"Eaton FRCMM-125/4/003-G/B — Residual current circuit-breaker, all-current sensitive, 125 A, 4p, 30 mA, type G/B. Manufacturer CAD files for breakers equipment selection and layout, identified by article 171188.","equipment":["breakers","FRCMM-125/4/003-G/B — Residual current circuit-breaker, all-current sensitive, 125 A, 4p, 30 mA, type G/B"],"keywords":["Eaton","FRCMM-125/4/003-G/B — Residual current circuit-breaker, all-current sensitive, 125 A, 4p, 30 mA, type G/B","171188","breakers","DWG","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"171188","sourceUrl":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip","officialEvidenceUrl":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip","sourcePublisher":"Eaton","formats":["DWG","STEP"],"availability":"direct","accessNote":"Download the retained manufacturer CAD originals from this library. ZIP packages contain the unchanged named native CAD file; manufacturer archive provenance is retained separately.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"171188","sourceUrl":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip"},{"label":"Manufacturer type","value":"FRCMM-125/4/003-G/B","sourceUrl":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip"},{"label":"Available native formats","value":"DWG / STEP","sourceUrl":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-859cbbb9056e3acde61d7047-step","name":"eaton-residual-current-circuit-breakers-3d-models-dfs-4.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip","availability":"direct","sha256":"859cbbb9056e3acde61d70474dc21dec2436480adbb38db89551f101c5cbfca1","bytes":275232,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"eaton-residual-current-circuit-breakers-3d-models-dfs-4.stp.zip","format":"ZIP","sha256":"e2c9ead848ad60e657721e767a5ba2129222a749800f34d91be0966510e16742","bytes":49161,"includes":["eaton-residual-current-circuit-breakers-3d-models-dfs-4.stp"]},"rightsReview":{"checkedAt":"2026-11-18T05:37:13.981462+00:00","sources":["https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip","https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html"],"note":"Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T05:06:56.690334+00:00","sourceArchive":{"url":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip","sha256":"4d83d7812ec166bb18d4fdf28e618abe30d943be63fca235abb96ee851efab17","member":"eaton-residual-current-circuit-breakers-3d-models-dfs-4.stp","publisherMemberChecksumVerified":true},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T05:37:13.981462+00:00","evidenceUrl":"https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","attribution":"Eaton"},"previewGroup":"eaton-article-171188","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/eaton-article-171188/native-859cbbb9056e3acde61d7047-step"},{"id":"native-db774e3a5cbda281e857d612-dwg","name":"eaton-residual-current-circuit-breakers-drawings-dfs-4.dwg","format":"DWG","purpose":"Manufacturer DWG CAD file","url":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip","availability":"direct","sha256":"db774e3a5cbda281e857d612e3558c8156e14af9a36872591d37fbd127c3a3fb","bytes":509408,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"eaton-residual-current-circuit-breakers-drawings-dfs-4.dwg.zip","format":"ZIP","sha256":"80291a638c71c5d6fafc2f3d5df8fe979513e2d9502256af85f0e74f7492278c","bytes":451053,"includes":["eaton-residual-current-circuit-breakers-drawings-dfs-4.dwg"]},"rightsReview":{"checkedAt":"2026-11-18T05:37:13.981462+00:00","sources":["https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip","https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html"],"note":"Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T05:06:56.690334+00:00","sourceArchive":{"url":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip","sha256":"4d83d7812ec166bb18d4fdf28e618abe30d943be63fca235abb96ee851efab17","member":"eaton-residual-current-circuit-breakers-drawings-dfs-4.dwg","publisherMemberChecksumVerified":true},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T05:37:13.981462+00:00","evidenceUrl":"https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","attribution":"Eaton"},"previewGroup":"eaton-article-171188","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/eaton-article-171188/native-db774e3a5cbda281e857d612-dwg"}],"artifacts":[{"id":"native-859cbbb9056e3acde61d7047-step","name":"eaton-residual-current-circuit-breakers-3d-models-dfs-4.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip","sourceSha256":"859cbbb9056e3acde61d70474dc21dec2436480adbb38db89551f101c5cbfca1","artifactSha256":"e2c9ead848ad60e657721e767a5ba2129222a749800f34d91be0966510e16742","bytes":49161,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/eaton-article-171188/native-859cbbb9056e3acde61d7047-step","customerPrice":0},{"id":"native-db774e3a5cbda281e857d612-dwg","name":"eaton-residual-current-circuit-breakers-drawings-dfs-4.dwg","format":"DWG","purpose":"Manufacturer DWG CAD file","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip","sourceSha256":"db774e3a5cbda281e857d612e3558c8156e14af9a36872591d37fbd127c3a3fb","artifactSha256":"80291a638c71c5d6fafc2f3d5df8fe979513e2d9502256af85f0e74f7492278c","bytes":451053,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/eaton-article-171188/native-db774e3a5cbda281e857d612-dwg","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"FRCMM-125/4/003-G/B — Residual current circuit-breaker, all-current sensitive, 125 A, 4p, 30 mA, type G/B"},{"label":"Manufacturer","value":"Eaton"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"171188"},{"label":"Manufacturer reference","value":"171188"},{"label":"Manufacturer type","value":"FRCMM-125/4/003-G/B"},{"label":"Available native formats","value":"DWG / STEP"},{"label":"Listed file formats","value":"DWG, STEP"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"1 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/eaton-article-171188/native-db774e3a5cbda281e857d612-dwg?asset=db774e3a5cbda281e857d612e3558c8156e14af9a36872591d37fbd127c3a3fb","relatedReferences":[{"name":"Air circuit breaker","url":"https://eloragrid.ai/objects/ga-air-circuit-breaker"},{"name":"Moulded-case circuit breaker","url":"https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker"}],"fileChoiceGuidance":["Start with 171188. The files above belong to Eaton's FRCMM-125/4/003-G/B — Residual current circuit-breaker, all-current sensitive, 125 A, 4p, 30 mA, type G/B resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, DWG. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A residual-current device compares the current leaving a circuit with the current returning. A difference can indicate current flowing along an unintended path, causing the device to trip. An RCBO also provides overcurrent protection.","example":"In a substation services board, it can protect a suitable maintenance-outlet circuit by detecting a current imbalance.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Outgoing and returning current","Difference is checked","Circuit disconnects if it trips"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Eaton official source","url":"https://ecat.eaton.com/downloads/9f08bf9e-de43-44ba-a162-b6f2c61f2b2e/cad_files_001.zip"}],"profileId":"rccb"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/eaton-article-171188"}