{"id":"eaton-article-178136","name":"LS-11/L-M12A — Position switch, Roller lever, Complete device, 1 N/O, 1 NC, Cage Clamp, Yellow, Insulated material, -25 - +70 °C, with M12 connector, EN 50047 Form E, Long","manufacturer":"Eaton","category":"wiring","description":"Eaton LS-11/L-M12A — Position switch, Roller lever, Complete device, 1 N/O, 1 NC, Cage Clamp, Yellow, Insulated material, -25 - +70 °C, with M12 connector, EN 50047 Form E, Long. Manufacturer CAD files for wiring equipment selection and layout, identified by article 178136.","equipment":["wiring","LS-11/L-M12A — Position switch, Roller lever, Complete device, 1 N/O, 1 NC, Cage Clamp, Yellow, Insulated material, -25 - +70 °C, with M12 connector, EN 50047 Form E, Long"],"keywords":["Eaton","LS-11/L-M12A — Position switch, Roller lever, Complete device, 1 N/O, 1 NC, Cage Clamp, Yellow, Insulated material, -25 - +70 °C, with M12 connector, EN 50047 Form E, Long","178136","wiring","DWG","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"178136","sourceUrl":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip","officialEvidenceUrl":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip","sourcePublisher":"Eaton","formats":["DWG","STEP"],"availability":"direct","accessNote":"Download the retained manufacturer CAD originals from this library. ZIP packages contain the unchanged named native CAD file; manufacturer archive provenance is retained separately.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"178136","sourceUrl":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip"},{"label":"Manufacturer type","value":"LS-11/L-M12A","sourceUrl":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip"},{"label":"Available native formats","value":"DWG / STEP","sourceUrl":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-72c2689187a1863100fa69c7-step","name":"ls_l_4a.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip","availability":"direct","sha256":"72c2689187a1863100fa69c77e50f80fb42b740a6c4f7c49a6fa5a0947c865d7","bytes":540780,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"ls_l_4a.stp.zip","format":"ZIP","sha256":"20869ad432b1a826908c7cf0d3cfc523918829a29c873572451984fa3ca20420","bytes":78751,"includes":["ls_l_4a.stp"]},"rightsReview":{"checkedAt":"2026-11-18T05:37:13.981462+00:00","sources":["https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip","https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html"],"note":"Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T05:10:54.749928+00:00","sourceArchive":{"url":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip","sha256":"50c9f348650d864a34a3f4026da349dbd41c1bd807224d2fa55b8d62b0f73ff6","member":"ls_l_4a.stp","publisherMemberChecksumVerified":true},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T05:37:13.981462+00:00","evidenceUrl":"https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","attribution":"Eaton"},"previewGroup":"eaton-article-178136","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/eaton-article-178136/native-72c2689187a1863100fa69c7-step"},{"id":"native-8a2ab819c72e325174b8f85f-dwg","name":"eaton-mechanical-limit-switches-mcad-drawings-ls-l-4a.dwg","format":"DWG","purpose":"Manufacturer DWG CAD file","url":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip","availability":"direct","sha256":"8a2ab819c72e325174b8f85f12b84a58907a17902dbd16ccef22f05ac22001c0","bytes":664269,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"eaton-mechanical-limit-switches-mcad-drawings-ls-l-4a.dwg.zip","format":"ZIP","sha256":"3095c50afc35a2d31723085dfe1edb82b4cf3e3cca9104ec7894a31b1af62c27","bytes":493010,"includes":["eaton-mechanical-limit-switches-mcad-drawings-ls-l-4a.dwg"]},"rightsReview":{"checkedAt":"2026-11-18T05:37:13.981462+00:00","sources":["https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip","https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html"],"note":"Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T05:10:54.749928+00:00","sourceArchive":{"url":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip","sha256":"50c9f348650d864a34a3f4026da349dbd41c1bd807224d2fa55b8d62b0f73ff6","member":"eaton-mechanical-limit-switches-mcad-drawings-ls-l-4a.dwg","publisherMemberChecksumVerified":true},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T05:37:13.981462+00:00","evidenceUrl":"https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","attribution":"Eaton"},"previewGroup":"eaton-article-178136","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/eaton-article-178136/native-8a2ab819c72e325174b8f85f-dwg"}],"artifacts":[{"id":"native-72c2689187a1863100fa69c7-step","name":"ls_l_4a.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip","sourceSha256":"72c2689187a1863100fa69c77e50f80fb42b740a6c4f7c49a6fa5a0947c865d7","artifactSha256":"20869ad432b1a826908c7cf0d3cfc523918829a29c873572451984fa3ca20420","bytes":78751,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/eaton-article-178136/native-72c2689187a1863100fa69c7-step","customerPrice":0},{"id":"native-8a2ab819c72e325174b8f85f-dwg","name":"eaton-mechanical-limit-switches-mcad-drawings-ls-l-4a.dwg","format":"DWG","purpose":"Manufacturer DWG CAD file","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip","sourceSha256":"8a2ab819c72e325174b8f85f12b84a58907a17902dbd16ccef22f05ac22001c0","artifactSha256":"3095c50afc35a2d31723085dfe1edb82b4cf3e3cca9104ec7894a31b1af62c27","bytes":493010,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/eaton-article-178136/native-8a2ab819c72e325174b8f85f-dwg","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"LS-11/L-M12A — Position switch, Roller lever, Complete device, 1 N/O, 1 NC, Cage Clamp, Yellow, Insulated material, -25 - +70 °C, with M12 connector, EN 50047 Form E, Long"},{"label":"Manufacturer","value":"Eaton"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"178136"},{"label":"Manufacturer reference","value":"178136"},{"label":"Manufacturer type","value":"LS-11/L-M12A"},{"label":"Available native formats","value":"DWG / STEP"},{"label":"Listed file formats","value":"DWG, STEP"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"1 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/eaton-article-178136/native-8a2ab819c72e325174b8f85f-dwg?asset=8a2ab819c72e325174b8f85f12b84a58907a17902dbd16ccef22f05ac22001c0","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 178136. The files above belong to Eaton's LS-11/L-M12A — Position switch, Roller lever, Complete device, 1 N/O, 1 NC, Cage Clamp, Yellow, Insulated material, -25 - +70 °C, with M12 connector, EN 50047 Form E, Long resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, DWG. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A limit switch changes its contacts when a moving part presses its operating mechanism. It reports that the part has reached a particular position.","example":"In switchgear, a limit switch can indicate the position of a withdrawable breaker mechanism.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Mechanism reaches a position","Limit switch operates","Position signal changes"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Eaton official source","url":"https://ecat.eaton.com/downloads/cf045bcb-7254-4ce0-a259-6f063471b16a/cad_files_001.zip"}],"profileId":"limit"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/eaton-article-178136"}