{"id":"eaton-article-189969","name":"DILMC115-EA(RAC240) — Contactor, 3 pole, 380 V 400 V 55 kW, RAC 240: 190 - 240 V 50/60 Hz, AC operation, Spring-loaded terminals","manufacturer":"Eaton","category":"wiring","description":"Eaton DILMC115-EA(RAC240) — Contactor, 3 pole, 380 V 400 V 55 kW, RAC 240: 190 - 240 V 50/60 Hz, AC operation, Spring-loaded terminals. Manufacturer CAD files for wiring equipment selection and layout, identified by article 189969.","equipment":["wiring","DILMC115-EA(RAC240) — Contactor, 3 pole, 380 V 400 V 55 kW, RAC 240: 190 - 240 V 50/60 Hz, AC operation, Spring-loaded terminals"],"keywords":["Eaton","DILMC115-EA(RAC240) — Contactor, 3 pole, 380 V 400 V 55 kW, RAC 240: 190 - 240 V 50/60 Hz, AC operation, Spring-loaded terminals","189969","wiring","DWG","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"189969","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","officialEvidenceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","sourcePublisher":"Eaton","formats":["DWG","STEP"],"availability":"direct","accessNote":"Download the retained manufacturer CAD originals from this library. ZIP packages contain the unchanged named native CAD file; manufacturer archive provenance is retained separately.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"189969","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip"},{"label":"Manufacturer type","value":"DILMC115-EA(RAC240)","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip"},{"label":"Available native formats","value":"DWG / STEP","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-5e54d83e4618490c5884adac-step","name":"dil_mc80_170.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","availability":"direct","sha256":"5e54d83e4618490c5884adacce90a76b3986877149b30847c2bbd897e232721e","bytes":617211,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"dil_mc80_170.stp.zip","format":"ZIP","sha256":"6773fe08e44360c81a499dd2627316b17858b3fc2ad2b8738d8ad3bee40f9422","bytes":81786,"includes":["dil_mc80_170.stp"]},"rightsReview":{"checkedAt":"2026-11-18T05:37:13.981462+00:00","sources":["https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html"],"note":"Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T05:11:14.303479+00:00","sourceArchive":{"url":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","sha256":"be66caffe711b7eba9fe64fe318ecab0cff3515feccb05fc47f93b74a2eb60b0","member":"dil_mc80_170.stp","publisherMemberChecksumVerified":true},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T05:37:13.981462+00:00","evidenceUrl":"https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","attribution":"Eaton"},"previewGroup":"eaton-article-189969","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/eaton-article-189969/native-5e54d83e4618490c5884adac-step"},{"id":"native-7b66ca2a4e74ae8b5bc10534-dwg","name":"eaton-iec-contactors-mcad-drawings-dil-mc80-170.dwg","format":"DWG","purpose":"Manufacturer DWG CAD file","url":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","availability":"direct","sha256":"7b66ca2a4e74ae8b5bc10534d23303eaf2427b5dd4104caead415622f9dd47f7","bytes":485280,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"eaton-iec-contactors-mcad-drawings-dil-mc80-170.dwg.zip","format":"ZIP","sha256":"2808a677505e6745867f9b6fadbed0e2e2b43253ed198e05f615304e0772c4de","bytes":380017,"includes":["eaton-iec-contactors-mcad-drawings-dil-mc80-170.dwg"]},"rightsReview":{"checkedAt":"2026-11-18T05:37:13.981462+00:00","sources":["https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html"],"note":"Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T05:11:14.303479+00:00","sourceArchive":{"url":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","sha256":"be66caffe711b7eba9fe64fe318ecab0cff3515feccb05fc47f93b74a2eb60b0","member":"eaton-iec-contactors-mcad-drawings-dil-mc80-170.dwg","publisherMemberChecksumVerified":true},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T05:37:13.981462+00:00","evidenceUrl":"https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","attribution":"Eaton"},"previewGroup":"eaton-article-189969","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/eaton-article-189969/native-7b66ca2a4e74ae8b5bc10534-dwg"}],"artifacts":[{"id":"native-5e54d83e4618490c5884adac-step","name":"dil_mc80_170.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","sourceSha256":"5e54d83e4618490c5884adacce90a76b3986877149b30847c2bbd897e232721e","artifactSha256":"6773fe08e44360c81a499dd2627316b17858b3fc2ad2b8738d8ad3bee40f9422","bytes":81786,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/eaton-article-189969/native-5e54d83e4618490c5884adac-step","customerPrice":0},{"id":"native-7b66ca2a4e74ae8b5bc10534-dwg","name":"eaton-iec-contactors-mcad-drawings-dil-mc80-170.dwg","format":"DWG","purpose":"Manufacturer DWG CAD file","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","sourceSha256":"7b66ca2a4e74ae8b5bc10534d23303eaf2427b5dd4104caead415622f9dd47f7","artifactSha256":"2808a677505e6745867f9b6fadbed0e2e2b43253ed198e05f615304e0772c4de","bytes":380017,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/eaton-article-189969/native-7b66ca2a4e74ae8b5bc10534-dwg","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"DILMC115-EA(RAC240) — Contactor, 3 pole, 380 V 400 V 55 kW, RAC 240: 190 - 240 V 50/60 Hz, AC operation, Spring-loaded terminals"},{"label":"Manufacturer","value":"Eaton"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"189969"},{"label":"Manufacturer reference","value":"189969"},{"label":"Manufacturer type","value":"DILMC115-EA(RAC240)"},{"label":"Available native formats","value":"DWG / STEP"},{"label":"Listed file formats","value":"DWG, STEP"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"1 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/eaton-article-189969/native-7b66ca2a4e74ae8b5bc10534-dwg?asset=7b66ca2a4e74ae8b5bc10534d23303eaf2427b5dd4104caead415622f9dd47f7","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 189969. The files above belong to Eaton's DILMC115-EA(RAC240) — Contactor, 3 pole, 380 V 400 V 55 kW, RAC 240: 190 - 240 V 50/60 Hz, AC operation, Spring-loaded terminals resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, DWG. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A terminal provides an identified point for joining wires to equipment or to other wires. Terminal strips organise those connections so they can be wired and checked.","example":"In a substation relay panel, numbered terminals connect the switchyard cables to the protection and control equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field wiring","Identified terminal connections","Panel equipment"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Eaton official source","url":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip"}],"profileId":"terminal"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/eaton-article-189969"}