{"id":"eaton-article-189979","name":"DILEEM-10-EA(230V50HZ,240V60HZ) — Contactor, 230 V 50 Hz, 240 V 60 Hz, 3 pole, 380 V 400 V, 3 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, AC operation","manufacturer":"Eaton","category":"wiring","description":"Eaton DILEEM-10-EA(230V50HZ,240V60HZ) — Contactor, 230 V 50 Hz, 240 V 60 Hz, 3 pole, 380 V 400 V, 3 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, AC operation. Manufacturer CAD files for wiring equipment selection and layout, identified by article 189979.","equipment":["wiring","DILEEM-10-EA(230V50HZ,240V60HZ) — Contactor, 230 V 50 Hz, 240 V 60 Hz, 3 pole, 380 V 400 V, 3 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, AC operation"],"keywords":["Eaton","DILEEM-10-EA(230V50HZ,240V60HZ) — Contactor, 230 V 50 Hz, 240 V 60 Hz, 3 pole, 380 V 400 V, 3 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, AC operation","189979","wiring","DWG","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"189979","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","officialEvidenceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","sourcePublisher":"Eaton","formats":["DWG","STEP"],"availability":"direct","accessNote":"Download the retained manufacturer CAD originals from this library. ZIP packages contain the unchanged named native CAD file; manufacturer archive provenance is retained separately.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"189979","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip"},{"label":"Manufacturer type","value":"DILEEM-10-EA(230V50HZ,240V60HZ)","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip"},{"label":"Available native formats","value":"DWG / STEP","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-79b08398c8445de43ae7a5ae-step","name":"dil_em.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","availability":"direct","sha256":"79b08398c8445de43ae7a5aeb12a968ae35791cfac3929532309106a288ed985","bytes":1084258,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"dil_em.stp.zip","format":"ZIP","sha256":"0cfbab4cf1d61e60787027c03a1e27f61715eec9f29840680c403c805e6dd932","bytes":139994,"includes":["dil_em.stp"]},"rightsReview":{"checkedAt":"2026-11-18T05:37:13.981462+00:00","sources":["https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html"],"note":"Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T05:11:14.303479+00:00","sourceArchive":{"url":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","sha256":"be66caffe711b7eba9fe64fe318ecab0cff3515feccb05fc47f93b74a2eb60b0","member":"dil_em.stp","publisherMemberChecksumVerified":true},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T05:37:13.981462+00:00","evidenceUrl":"https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","attribution":"Eaton"},"previewGroup":"eaton-article-189979","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/eaton-article-189979/native-79b08398c8445de43ae7a5ae-step"},{"id":"native-0f72c153e582d7718fe9d7e2-dwg","name":"eaton-contactor-relays-mcad-drawings-dil-em.dwg","format":"DWG","purpose":"Manufacturer DWG CAD file","url":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","availability":"direct","sha256":"0f72c153e582d7718fe9d7e2d6dbc42e01016da8ad3bdf797adf89cc5b6b9692","bytes":590688,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"eaton-contactor-relays-mcad-drawings-dil-em.dwg.zip","format":"ZIP","sha256":"f7fc0b479618e75ef775ee90404c37d0ec75e28de1275d2482b5b7450a36ecdc","bytes":476453,"includes":["eaton-contactor-relays-mcad-drawings-dil-em.dwg"]},"rightsReview":{"checkedAt":"2026-11-18T05:37:13.981462+00:00","sources":["https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html"],"note":"Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T05:11:14.303479+00:00","sourceArchive":{"url":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","sha256":"be66caffe711b7eba9fe64fe318ecab0cff3515feccb05fc47f93b74a2eb60b0","member":"eaton-contactor-relays-mcad-drawings-dil-em.dwg","publisherMemberChecksumVerified":true},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T05:37:13.981462+00:00","evidenceUrl":"https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf","attribution":"Eaton"},"previewGroup":"eaton-article-189979","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/eaton-article-189979/native-0f72c153e582d7718fe9d7e2-dwg"}],"artifacts":[{"id":"native-79b08398c8445de43ae7a5ae-step","name":"dil_em.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","sourceSha256":"79b08398c8445de43ae7a5aeb12a968ae35791cfac3929532309106a288ed985","artifactSha256":"0cfbab4cf1d61e60787027c03a1e27f61715eec9f29840680c403c805e6dd932","bytes":139994,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/eaton-article-189979/native-79b08398c8445de43ae7a5ae-step","customerPrice":0},{"id":"native-0f72c153e582d7718fe9d7e2-dwg","name":"eaton-contactor-relays-mcad-drawings-dil-em.dwg","format":"DWG","purpose":"Manufacturer DWG CAD file","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip","sourceSha256":"0f72c153e582d7718fe9d7e2d6dbc42e01016da8ad3bdf797adf89cc5b6b9692","artifactSha256":"f7fc0b479618e75ef775ee90404c37d0ec75e28de1275d2482b5b7450a36ecdc","bytes":476453,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/eaton-article-189979/native-0f72c153e582d7718fe9d7e2-dwg","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"DILEEM-10-EA(230V50HZ,240V60HZ) — Contactor, 230 V 50 Hz, 240 V 60 Hz, 3 pole, 380 V 400 V, 3 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, AC operation"},{"label":"Manufacturer","value":"Eaton"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"189979"},{"label":"Manufacturer reference","value":"189979"},{"label":"Manufacturer type","value":"DILEEM-10-EA(230V50HZ,240V60HZ)"},{"label":"Available native formats","value":"DWG / STEP"},{"label":"Listed file formats","value":"DWG, STEP"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"1 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/eaton-article-189979/native-0f72c153e582d7718fe9d7e2-dwg?asset=0f72c153e582d7718fe9d7e2d6dbc42e01016da8ad3bdf797adf89cc5b6b9692","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 189979. The files above belong to Eaton's DILEEM-10-EA(230V50HZ,240V60HZ) — Contactor, 230 V 50 Hz, 240 V 60 Hz, 3 pole, 380 V 400 V, 3 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, AC operation resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, DWG. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A terminal provides an identified point for joining wires to equipment or to other wires. Terminal strips organise those connections so they can be wired and checked.","example":"In a substation relay panel, numbered terminals connect the switchyard cables to the protection and control equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Field wiring","Identified terminal connections","Panel equipment"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Eaton official source","url":"https://ecat.eaton.com/downloads/fa7f0a1e-de82-41e5-a418-2e80c17b4d38/cad_files_001.zip"}],"profileId":"terminal"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/eaton-article-189979"}