# RAMO5-D214A31-5120S1 — DOL starter, 6.6 A, Sensor input 2, Actuator output 1, 400/480 V AC, AS-Interface®, S-7.4 for 31 modules, HAN Q5

Eaton RAMO5-D214A31-5120S1 — DOL starter, 6.6 A, Sensor input 2, Actuator output 1, 400/480 V AC, AS-Interface®, S-7.4 for 31 modules, HAN Q5. Manufacturer CAD files for automation equipment selection and layout, identified by article 198528.

## Equipment and file summary

Equipment / resource: RAMO5-D214A31-5120S1 — DOL starter, 6.6 A, Sensor input 2, Actuator output 1, 400/480 V AC, AS-Interface®, S-7.4 for 31 modules, HAN Q5
Manufacturer: Eaton
Resource type: Product
Part number: 198528
Manufacturer reference: 198528
Manufacturer type: RAMO5-D214A31-5120S1
Available native formats: DWG / STEP
Listed file formats: DWG, STEP
Listed files: 2
Available previews: 1 drawing previews
Recorded revisions: Confirm the revision with the manufacturer
Source checked: 2026-11-17
Download access: Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply.

## Related GA references

- [PLC CPU module](https://eloragrid.ai/objects/ga-plc-cpu-module)
- [HMI touchscreen](https://eloragrid.ai/objects/ga-hmi-touchscreen)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/eaton-article-198528
Manufacturer: Eaton
Entry type: Product
Part number: 198528
Category: Automation & controls
Formats: DWG, STEP
Market discovery: Global
Access: Direct download
Official source: https://ecat.eaton.com/downloads/8bc4a502-51da-4a9e-95ae-f9896cb8714f/cad_files_001.zip
Manufacturer evidence: https://ecat.eaton.com/downloads/8bc4a502-51da-4a9e-95ae-f9896cb8714f/cad_files_001.zip
Source checked: 2026-11-17T15:50:41.709187+00:00

Download the retained manufacturer CAD originals from this library. ZIP packages contain the unchanged named native CAD file; manufacturer archive provenance is retained separately.
Confirm regional configuration, ratings and approvals with the manufacturer.
Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.


## In plain English

### What the equipment does

An actuator turns a control input into physical movement, such as moving a valve or operating a mechanism.

### A simple example

In a microgrid generator system, an electrically operated valve can control an auxiliary fluid path when the controller requests it.

### What the drawings help you do

Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Control input → Actuator moves → Mechanism changes position
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [Eaton official source](https://ecat.eaton.com/downloads/8bc4a502-51da-4a9e-95ae-f9896cb8714f/cad_files_001.zip)


## Which file should I choose?

Start with 198528. The files above belong to Eaton's RAMO5-D214A31-5120S1 — DOL starter, 6.6 A, Sensor input 2, Actuator output 1, 400/480 V AC, AS-Interface®, S-7.4 for 31 modules, HAN Q5 resource; match any model or option suffix in the filename to your selected unit.
Available here: STEP, DWG. The individual filenames above distinguish the supplied variants.

## Official files

- ramo5_v2.stp (STEP): https://ecat.eaton.com/downloads/8bc4a502-51da-4a9e-95ae-f9896cb8714f/cad_files_001.zip
  Download access: public; public_original
  Site download: https://eloragrid.ai/tools/cad-library/download/eaton-article-198528/native-fddc2be3b1e30c5badaa8b05-step
  Hosting basis: no-explicit-prohibition; publisher attribution: Eaton; reviewed: 2026-11-18T05:37:13.981462+00:00
  Rights review: Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed.; evidence: https://ecat.eaton.com/downloads/8bc4a502-51da-4a9e-95ae-f9896cb8714f/cad_files_001.zip, https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf, https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html
  Purpose: Manufacturer STEP CAD file; acquired: true; redistribution: unknown; SHA-256: fddc2be3b1e30c5badaa8b0594186977db3a4f47ac8c912d9c1fd159c382661e; revision: not recorded
- eaton-motor-starter-mcad-drawings-ramo5-v2.dwg (DWG): https://ecat.eaton.com/downloads/8bc4a502-51da-4a9e-95ae-f9896cb8714f/cad_files_001.zip
  Download access: public; public_original
  Site download: https://eloragrid.ai/tools/cad-library/download/eaton-article-198528/native-5be17a78b0b76ffb30942a82-dwg
  Hosting basis: no-explicit-prohibition; publisher attribution: Eaton; reviewed: 2026-11-18T05:37:13.981462+00:00
  Rights review: Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed.; evidence: https://ecat.eaton.com/downloads/8bc4a502-51da-4a9e-95ae-f9896cb8714f/cad_files_001.zip, https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf, https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html
  Purpose: Manufacturer DWG CAD file; acquired: true; redistribution: unknown; SHA-256: 5be17a78b0b76ffb30942a8230a8b2acc9dff28c05deb8ea21658c39e73f21bb; revision: not recorded

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.