# DILM32-21(RDC24) — Contactor, 380 V 400 V 15 kW, 2 N/O, 1 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals

Eaton DILM32-21(RDC24) — Contactor, 380 V 400 V 15 kW, 2 N/O, 1 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals. Manufacturer CAD files for wiring equipment selection and layout, identified by article 277338.

## Equipment and file summary

Equipment / resource: DILM32-21(RDC24) — Contactor, 380 V 400 V 15 kW, 2 N/O, 1 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals
Manufacturer: Eaton
Resource type: Product
Part number: 277338
Manufacturer reference: 277338
Manufacturer type: DILM32-21(RDC24)
Available native formats: DWG / STEP
Listed file formats: DWG, STEP
Listed files: 2
Available previews: 1 drawing previews
Recorded revisions: Confirm the revision with the manufacturer
Source checked: 2026-11-17
Download access: Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply.

## Related GA references

- [Terminal strip assembly](https://eloragrid.ai/objects/terminal-strip)
- [Cable gland](https://eloragrid.ai/objects/ga-cable-gland)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/eaton-article-277338
Manufacturer: Eaton
Entry type: Product
Part number: 277338
Category: Wiring & terminals
Formats: DWG, STEP
Market discovery: Global
Access: Direct download
Official source: https://ecat.eaton.com/downloads/ed4e1bd3-b966-4647-822d-9354c5b1e2d9/cad_files_001.zip
Manufacturer evidence: https://ecat.eaton.com/downloads/ed4e1bd3-b966-4647-822d-9354c5b1e2d9/cad_files_001.zip
Source checked: 2026-11-17T15:50:41.709187+00:00

Download the retained manufacturer CAD originals from this library. ZIP packages contain the unchanged named native CAD file; manufacturer archive provenance is retained separately.
Confirm regional configuration, ratings and approvals with the manufacturer.
Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.


## In plain English

### What the equipment does

A terminal provides an identified point for joining wires to equipment or to other wires. Terminal strips organise those connections so they can be wired and checked.

### A simple example

In a substation relay panel, numbered terminals connect the switchyard cables to the protection and control equipment.

### What the drawings help you do

Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Field wiring → Identified terminal connections → Panel equipment
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [Eaton official source](https://ecat.eaton.com/downloads/ed4e1bd3-b966-4647-822d-9354c5b1e2d9/cad_files_001.zip)


## Which file should I choose?

Start with 277338. The files above belong to Eaton's DILM32-21(RDC24) — Contactor, 380 V 400 V 15 kW, 2 N/O, 1 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals resource; match any model or option suffix in the filename to your selected unit.
Available here: STEP, DWG. The individual filenames above distinguish the supplied variants.

## Official files

- dil_m17_38_a_xhi.stp (STEP): https://ecat.eaton.com/downloads/ed4e1bd3-b966-4647-822d-9354c5b1e2d9/cad_files_001.zip
  Download access: public; public_original
  Site download: https://eloragrid.ai/tools/cad-library/download/eaton-article-277338/native-424e1410a59b49890e408776-step
  Hosting basis: no-explicit-prohibition; publisher attribution: Eaton; reviewed: 2026-11-18T05:37:13.981462+00:00
  Rights review: Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed.; evidence: https://ecat.eaton.com/downloads/ed4e1bd3-b966-4647-822d-9354c5b1e2d9/cad_files_001.zip, https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf, https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html
  Purpose: Manufacturer STEP CAD file; acquired: true; redistribution: unknown; SHA-256: 424e1410a59b49890e4087761a71e685754960f97784e42ca23a9fcc36ff2244; revision: not recorded
- eaton-iec-contactors-mcad-drawings-dil-m17-38-a-xhi.dwg (DWG): https://ecat.eaton.com/downloads/ed4e1bd3-b966-4647-822d-9354c5b1e2d9/cad_files_001.zip
  Download access: public; public_original
  Site download: https://eloragrid.ai/tools/cad-library/download/eaton-article-277338/native-335d46a83c9c6800fdb700e6-dwg
  Hosting basis: no-explicit-prohibition; publisher attribution: Eaton; reviewed: 2026-11-18T05:37:13.981462+00:00
  Rights review: Manufacturer copyright retained. Download Center partner guidance and website terms reviewed; an explicit public redistribution licence remains unverified. Hosted under the reviewed no-explicit-prohibition policy; no separate written permission or explicit licence is claimed.; evidence: https://ecat.eaton.com/downloads/ed4e1bd3-b966-4647-822d-9354c5b1e2d9/cad_files_001.zip, https://ecat.eaton.com/downloads/06.02_TD_Manual_DC_Download_Center_V5_EXTERNAL_version.pdf, https://www.eaton.com/us/en-us/company/policies-and-statements/terms-and-conditions.html
  Purpose: Manufacturer DWG CAD file; acquired: true; redistribution: unknown; SHA-256: 335d46a83c9c6800fdb700e6fba3cc905000792c928b189dd8392a5bdef141f8; revision: not recorded

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.