{"id":"lapp-insulators-314982-70","name":"314982-70 cap-and-pin replacement insulator","manufacturer":"LAPP Insulators","category":"switchgear","description":"314982-70 cap-and-pin replacement insulator from LAPP Insulators. The manufacturer table lists Leakage Distance, Reference Standard, in. [mm]: 66 [1676]; Cantilever Strength, Upright, lbs. [kN]: 4500 [20.0]; Tensile Strength, lbs. [kN]: 20000 [89.0]. Download the source catalogue and inspect the 314982-70 column.","equipment":["cap-and-pin replacement insulator","314982-70"],"keywords":["314982-70","314982-70","cap-and-pin replacement insulator","insulator","station post","switchyard","substation"],"markets":["Global"],"marketNote":"The source table supplies the listed product values. The project insulation, mechanical loading and regional requirements must be checked for the selected installation.","kind":"product","sourceUrl":"https://us.lappinsulators.com/documentation/","officialEvidenceUrl":"https://us.lappinsulators.com/wp-content/uploads/2026/06/Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf#page=15","sourcePublisher":"LAPP Insulators","formats":["PDF"],"availability":"direct","accessNote":"Download the verified original here. The manufacturer source is linked for revision checks; preview images are for inspection and the original drawing supplies the design dimensions.","checkedAt":"2026-11-03","files":[{"id":"catalogue","name":"Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf","filenameBasis":"source-url","format":"PDF","purpose":"Manufacturer catalogue with 314982-70 data and outline references on PDF page 15","url":"https://us.lappinsulators.com/wp-content/uploads/2026/06/Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf","availability":"direct","bytes":2921612,"sha256":"17822b1ba7c6ddb509667aa0122652c7abb69f63ddfbc67014baa98a3f856ae3","retrievedAt":"2026-11-03T01:38:01.607984+00:00","validation":"signature-checked","hosted":true,"redistribution":"unknown","previewPages":[15],"rightsReview":{"checkedAt":"2026-11-03","sources":["https://us.lappinsulators.com/documentation/","https://us.lappinsulators.com/wp-content/uploads/2026/06/Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf"],"note":"Current manufacturer download listing and the complete catalogue text were inspected. No explicit reproduction prohibition was identified in this catalogue. Copyright remains with the named manufacturer; no redistribution licence is asserted."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-03","evidenceUrl":"https://us.lappinsulators.com/documentation/","attribution":"LAPP Insulators"},"delivery":{"kind":"original","name":"Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf","format":"PDF","sha256":"17822b1ba7c6ddb509667aa0122652c7abb69f63ddfbc67014baa98a3f856ae3","bytes":2921612,"includes":["Unchanged official original"]},"downloadUrl":"https://eloragrid.ai/tools/cad-library/download/lapp-insulators-314982-70/catalogue"}],"fileClasses":["cap-and-pin replacement insulator","manufacturer model-specific table","catalogue outline reference"],"configurationNote":"Use the 314982-70 column on PDF page 15. The download is the complete catalogue, not a standalone DWG or STEP part.","applications":["switchyards","substations"],"technicalFacts":[{"label":"Leakage Distance, Reference Standard, in. [mm]","value":"66 [1676]","sourceUrl":"https://us.lappinsulators.com/wp-content/uploads/2026/06/Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf#page=15"},{"label":"Cantilever Strength, Upright, lbs. [kN]","value":"4500 [20.0]","sourceUrl":"https://us.lappinsulators.com/wp-content/uploads/2026/06/Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf#page=15"},{"label":"Tensile Strength, lbs. [kN]","value":"20000 [89.0]","sourceUrl":"https://us.lappinsulators.com/wp-content/uploads/2026/06/Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf#page=15"},{"label":"Compression Strength, lbs. [kN]","value":"60000 [266.9]","sourceUrl":"https://us.lappinsulators.com/wp-content/uploads/2026/06/Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf#page=15"},{"label":"Impulse Withstand, kV","value":"350*","sourceUrl":"https://us.lappinsulators.com/wp-content/uploads/2026/06/Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf#page=15"},{"label":"Net Weight, Each, lbs. [kg]","value":"161.1 [73.1]","sourceUrl":"https://us.lappinsulators.com/wp-content/uploads/2026/06/Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf#page=15"}],"partNumber":"314982-70","equipmentFacts":[{"label":"Equipment / resource","value":"314982-70 cap-and-pin replacement insulator"},{"label":"Manufacturer","value":"LAPP Insulators"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"314982-70"},{"label":"Leakage Distance, Reference Standard, in. [mm]","value":"66 [1676]"},{"label":"Cantilever Strength, Upright, lbs. [kN]","value":"4500 [20.0]"},{"label":"Tensile Strength, lbs. [kN]","value":"20000 [89.0]"},{"label":"Compression Strength, lbs. [kN]","value":"60000 [266.9]"},{"label":"Impulse Withstand, kV","value":"350*"},{"label":"Net Weight, Each, lbs. [kg]","value":"161.1 [73.1]"},{"label":"Listed file formats","value":"PDF"},{"label":"Listed files","value":"1"},{"label":"Available previews","value":"1 catalogue page previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-03"},{"label":"Download access","value":"Email registration for site downloads; official source links are also available"}],"previewImage":"/tools/cad-library/drawing-preview/lapp-insulators-314982-70/catalogue?asset=041db2ba2080bab0c0386b2de68d37b112a7f74d741f102e206bf2194394fd3d","relatedReferences":[{"name":"Switchgear panel","url":"https://eloragrid.ai/objects/switchgear-panel"},{"name":"Switchboard","url":"https://eloragrid.ai/objects/switchboard"},{"name":"Ring main unit","url":"https://eloragrid.ai/objects/ring-main-unit"}],"fileChoiceGuidance":["Download Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf and open PDF page 15. Find the 314982-70 column; other tables and model rows or columns describe different insulators. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model."],"plainEnglish":{"title":"What the equipment does","introduction":"A station-post insulator supports an energised conductor while separating it electrically from its grounded support. Its end fittings, height and mechanical strength determine how it can be mounted.","example":"When positioning 314982-70 on a substation support, use PDF page 15 to compare its mounting interfaces with the structure and conductor connection. The listed Leakage Distance, Reference Standard, in. [mm] is 66 [1676].","drawings":"Download Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf and open PDF page 15. Find the 314982-70 column; other tables and model rows or columns describe different insulators. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Identify the support position","Match the named reference and fixing","Coordinate the structure and conductor"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"LAPP Insulators official source","url":"https://us.lappinsulators.com/wp-content/uploads/2026/06/Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf#page=15"}],"profileId":"station-post-insulator","checklist":["For 314982-70, the source records Leakage Distance, Reference Standard, in. [mm]: 66 [1676]. Match that value to the conductor-support arrangement.","Compare the 314982-70 column on PDF page 15 with the exact fixing or stud arrangement shown in the catalogue; use the dimensions for this exact reference.","The source also lists Cantilever Strength, Upright, lbs. [kN]: 4500 [20.0]. Check the project requirement against the manufacturer’s specified units and conditions.","Leakage distance follows the insulating surface. It is different from the overall height; use the height value for the physical layout."],"questions":[{"question":"Where is the 314982-70 information in this download?","answer":"Open PDF page 15 of Lapp-North-America_Cap-and-Pin-Replacement-Catalog.pdf and find the 314982-70 column. The page preview preserves the manufacturer table; the download contains the complete catalogue."},{"question":"Is an editable CAD model included for 314982-70?","answer":"This entry provides the manufacturer PDF reference and its model-specific values. A DWG, DXF or STEP model is not attached; request the exact model and preferred format here."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/lapp-insulators-314982-70"}