# 315225-70 porcelain station-post insulator

315225-70 porcelain station-post insulator from LAPP Insulators. The manufacturer table lists Leakage Distance, Reference Standard, in. [mm]: 15.5 [394]; Leakage Distance, High Leak, in. [mm]: 24.0 [610]; Cantilever Strength, lbs. [kN]: 4000 [17.8]. Download the source catalogue and inspect the 315225-70 column.

## Equipment and file summary

Equipment / resource: 315225-70 porcelain station-post insulator
Manufacturer: LAPP Insulators
Resource type: Product
Part number: 315225-70
Leakage Distance, Reference Standard, in. [mm]: 15.5 [394]
Leakage Distance, High Leak, in. [mm]: 24.0 [610]
Cantilever Strength, lbs. [kN]: 4000 [17.8]
Tensile Strength, lbs. [kN]: 20000 [89.0]
Compression Strength, lbs. [kN]: 20000 [89.0]
Impulse Withstand, kV: 110
Net Weight, Each, lbs. [kg]: 40.3 [18.3]
Listed file formats: PDF
Listed files: 1
Available previews: 1 catalogue page previews
Recorded revisions: Confirm the revision with the manufacturer
Source checked: 2026-11-03
Download access: Email registration for site downloads; official source links are also available

## Related GA references

- [Switchgear panel](https://eloragrid.ai/objects/switchgear-panel)
- [Switchboard](https://eloragrid.ai/objects/switchboard)
- [Ring main unit](https://eloragrid.ai/objects/ring-main-unit)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/lapp-insulators-315225-70
Manufacturer: LAPP Insulators
Entry type: Product
Part number: 315225-70
Category: Switchboards & switchgear
Formats: PDF
Market discovery: Global
Access: Direct download
Official source: https://us.lappinsulators.com/documentation/
Manufacturer evidence: https://us.lappinsulators.com/wp-content/uploads/2026/06/95-110kV.pdf#page=2
Source checked: 2026-11-03

Download the verified original here. The manufacturer source is linked for revision checks; preview images are for inspection and the original drawing supplies the design dimensions.
The source table supplies the listed product values. The project insulation, mechanical loading and regional requirements must be checked for the selected installation.
Use the 315225-70 column on PDF page 2. The download is the complete catalogue, not a standalone DWG or STEP part.


## In plain English

### What the equipment does

A station-post insulator supports an energised conductor while separating it electrically from its grounded support. Its end fittings, height and mechanical strength determine how it can be mounted.

### A simple example

When positioning 315225-70 on a substation support, use PDF page 2 to compare its mounting interfaces with the structure and conductor connection. The listed Leakage Distance, Reference Standard, in. [mm] is 15.5 [394].

### What the drawings help you do

Download 95-110kV.pdf and open PDF page 2. Find the 315225-70 column; other tables and model rows or columns describe different insulators. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model.

### Before using this reference

- For 315225-70, the source records Leakage Distance, Reference Standard, in. [mm]: 15.5 [394]. Match that value to the conductor-support arrangement.
- Compare the 315225-70 column on PDF page 2 with the exact fixing or stud arrangement shown in the catalogue; use the dimensions for this exact reference.
- The source also lists Leakage Distance, High Leak, in. [mm]: 24.0 [610]. Check the project requirement against the manufacturer’s specified units and conditions.
- Leakage distance follows the insulating surface. It is different from the overall height; use the height value for the physical layout.

### Where is the 315225-70 information in this download?

Open PDF page 2 of 95-110kV.pdf and find the 315225-70 column. The page preview preserves the manufacturer table; the download contains the complete catalogue.

### Is an editable CAD model included for 315225-70?

This entry provides the manufacturer PDF reference and its model-specific values. A DWG, DXF or STEP model is not attached; request the exact model and preferred format here.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Identify the support position → Match the named reference and fixing → Coordinate the structure and conductor
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [LAPP Insulators official source](https://us.lappinsulators.com/wp-content/uploads/2026/06/95-110kV.pdf#page=2)


## Which file should I choose?

Download 95-110kV.pdf and open PDF page 2. Find the 315225-70 column; other tables and model rows or columns describe different insulators. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model.

## Official files

- 95-110kV.pdf (PDF): https://us.lappinsulators.com/wp-content/uploads/2026/06/95-110kV.pdf
  Site download: https://eloragrid.ai/tools/cad-library/download/lapp-insulators-315225-70/catalogue
  Hosting basis: no-explicit-prohibition; publisher attribution: LAPP Insulators; reviewed: 2026-11-03
  Rights review: Current manufacturer download listing and the complete catalogue text were inspected. No explicit reproduction prohibition was identified in this catalogue. Copyright remains with the named manufacturer; no redistribution licence is asserted.; evidence: https://us.lappinsulators.com/documentation/, https://us.lappinsulators.com/wp-content/uploads/2026/06/95-110kV.pdf
  Purpose: Manufacturer catalogue with 315225-70 data and outline references on PDF page 2; acquired: true; redistribution: unknown; SHA-256: 48904ddeaf1fed2e47c9738fc75bd310f696e17c3578ba7316c440722a62839c; revision: not recorded

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.