{"id":"mfr-abb-4pole-low-voltage-mccb-series-isomax-rotary-handle-operating-mechanism-s7-e447e8972f","name":"4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7","manufacturer":"ABB","category":"breakers","description":"ABB 4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7: original DXF for circuit-breaker equipment layouts.","equipment":["circuit-breaker equipment","4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7"],"keywords":["ABB","4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7","ITSCE-601840291"],"markets":["Global"],"marketNote":"Manufacturer source discovery; confirm the exact regional equipment configuration and certification separately.","kind":"family","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601840291&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch","officialEvidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601840291&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch","sourcePublisher":"ABB","formats":["DXF"],"availability":"direct","accessNote":"Inspected originals are available from this website through the existing download email prompt.","checkedAt":"2026-11-11","files":[{"id":"abb-fed4170d4c6dafd49a4d","name":"ITSCE-601840291.dxf","format":"DXF","purpose":"Original manufacturer DXF geometry","url":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601840291&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E","availability":"direct","bytes":245002,"sha256":"701fbca8c4765091a171e8874908d8601382274826179c4c6b6a013d562c7fb9","retrievedAt":"2026-11-11T05:46:46.345183+00:00","sourceCheckedAt":"2026-11-11","validation":"signature-checked","filenameBasis":"document-reference","hosted":true,"redistribution":"unknown","rightsReview":{"checkedAt":"2026-11-11","sources":["https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601840291&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E"],"note":"Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-11","evidenceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601840291&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch","attribution":"ABB"},"delivery":{"kind":"original","format":"DXF","sha256":"701fbca8c4765091a171e8874908d8601382274826179c4c6b6a013d562c7fb9","bytes":245002,"includes":["ITSCE-601840291.dxf"]},"documentNumber":"ITSCE-601840291","latestRevisionUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601840291&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch","revision":"E","previewGroup":"mfr-abb-4pole-low-voltage-mccb-series-isomax-rotary-handle-operating-mechanism-s7-e447e8972f","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/mfr-abb-4pole-low-voltage-mccb-series-isomax-rotary-handle-operating-mechanism-s7-e447e8972f/abb-fed4170d4c6dafd49a4d"}],"fileClasses":["original manufacturer drawing or model source"],"technicalFacts":[{"label":"Manufacturer drawing identity","value":"4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601840291&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch"},{"label":"Source document","value":"ITSCE-601840291; revision E","sourceUrl":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601840291&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch&DocumentRevisionId=E"}],"applications":["switchgear"],"configurationNote":"Use the manufacturer configuration named 4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7.","equipmentFacts":[{"label":"Equipment / resource","value":"4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7"},{"label":"Manufacturer","value":"ABB"},{"label":"Resource type","value":"Product family"},{"label":"Manufacturer drawing identity","value":"4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7"},{"label":"Source document","value":"ITSCE-601840291; revision E"},{"label":"Listed file formats","value":"DXF"},{"label":"Listed files","value":"1"},{"label":"Available previews","value":"1 drawing previews"},{"label":"Recorded revisions","value":"E"},{"label":"Source checked","value":"2026-11-11"},{"label":"Download access","value":"Email registration for site downloads; official source links are also available"}],"previewImage":"/tools/cad-library/drawing-preview/mfr-abb-4pole-low-voltage-mccb-series-isomax-rotary-handle-operating-mechanism-s7-e447e8972f/abb-fed4170d4c6dafd49a4d?asset=701fbca8c4765091a171e8874908d8601382274826179c4c6b6a013d562c7fb9","relatedReferences":[{"name":"Air circuit breaker","url":"https://eloragrid.ai/objects/ga-air-circuit-breaker"},{"name":"Moulded-case circuit breaker","url":"https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker"}],"fileChoiceGuidance":["Use ITSCE-601840291.dxf (revision E) to insert the supplied editable drawing into your layout."],"plainEnglish":{"title":"What the equipment does","introduction":"A circuit breaker opens and closes a power circuit and can interrupt it when its protection or trip system responds to a fault.","example":"Use ITSCE-601840291.dxf (revision E) to insert the supplied editable drawing into your layout.","drawings":"Use ITSCE-601840291.dxf (revision E) to insert the supplied editable drawing into your layout.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Identify 4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7","Choose DXF","Check the matching source configuration"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"ABB official source","url":"https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601840291&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch"}],"profileId":"breaker","checklist":["Match ABB 4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7 and the exact source filename shown above.","The source was checked on 2026-11-11; recorded file revisions: ITSCE-601840291.dxf — E. Use Documentation & sources to check for a newer issue."],"questions":[{"question":"Which original files are supplied for 4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7?","answer":"1 inspected original for ABB 4Pole low voltage MCCB series Isomax - Rotary handle operating mechanism S7: ITSCE-601840291.dxf (DXF)."},{"question":"Where did these ABB files come from?","answer":"ABB supplied the original files through https://search.abb.com/library/Download.aspx?DocumentID=ITSCE-601840291&LanguageCode=en&LanguageCode=it&DocumentPartId=&Action=Launch. The source reference, revision, original bytes and checksum are retained with each download."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/mfr-abb-4pole-low-voltage-mccb-series-isomax-rotary-handle-operating-mechanism-s7-e447e8972f"}