# S2C-NT

ABB S2C-NT: original STEP for circuit-breaker equipment layouts. CAD Data MCB Acc. S2C-NT IGES.

## Equipment and file summary

Equipment / resource: S2C-NT
Manufacturer: ABB
Resource type: Product
Manufacturer configuration: CAD Data MCB Acc. S2C-NT IGES
Manufacturer drawing identity: S2C-NT
Source document: 2CDX405000C0037
Source-model envelope: 85 × 17.2 × 74.1 mm
2D preview basis: The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.
Listed file formats: STEP
Listed files: 1
Available previews: 1 drawing previews; 1 interactive model variants
Recorded revisions: Confirm the revision with the manufacturer
Source checked: 2026-11-11
Download access: Email registration for site downloads; official source links are also available

## Related GA references

- [Air circuit breaker](https://eloragrid.ai/objects/ga-air-circuit-breaker)
- [Moulded-case circuit breaker](https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/mfr-abb-s2c-nt-8f74901845
Manufacturer: ABB
Entry type: Product
Part number: Not specified — select exact configuration
Category: Breakers & accessories
Formats: STEP
Market discovery: Global
Access: Direct download
Official source: https://search.abb.com/library/Download.aspx?DocumentID=2CDX405000B0037&LanguageCode=en&DocumentPartId=&Action=Launch
Manufacturer evidence: https://search.abb.com/library/Download.aspx?DocumentID=2CDX405000B0037&LanguageCode=en&DocumentPartId=&Action=Launch
Source checked: 2026-11-11

Inspected originals are available from this website through the existing download email prompt.
Manufacturer source discovery; confirm the exact regional equipment configuration and certification separately.
CAD Data MCB Acc. S2C-NT IGES


## In plain English

### What the equipment does

A circuit breaker opens and closes a power circuit and can interrupt it when its protection or trip system responds to a fault.

### A simple example

Use 2CDX405000C0037.stp to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified 2CDX405000C0037.stp.

### What the drawings help you do

Use 2CDX405000C0037.stp to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified 2CDX405000C0037.stp.

### Before using this reference

- Match the recorded manufacturer configuration: CAD Data MCB Acc. S2C-NT IGES
- The supplied model has approximate X × Y × Z bounds of 85 × 17.2 × 74.1 mm. These are source-model axes; mounting holes and installation clearances must come from the matching manufacturer sheet.
- The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.
- The source was checked on 2026-11-11. Use Documentation & sources to check for a newer issue.

### Which original files are supplied for S2C-NT?

1 inspected original for ABB S2C-NT: 2CDX405000C0037.stp (STEP). The manufacturer describes this configuration as CAD Data MCB Acc. S2C-NT IGES.

### Where did these ABB files come from?

ABB supplied the original files through https://search.abb.com/library/Download.aspx?DocumentID=2CDX405000B0037&LanguageCode=en&DocumentPartId=&Action=Launch. The source reference, revision, original bytes and checksum are retained with each download.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Identify S2C-NT → Choose STEP → Check the matching source configuration
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [ABB official source](https://search.abb.com/library/Download.aspx?DocumentID=2CDX405000B0037&LanguageCode=en&DocumentPartId=&Action=Launch)


## Which file should I choose?

Use 2CDX405000C0037.stp to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified 2CDX405000C0037.stp.

## Official files

- 2CDX405000C0037.stp (STEP): https://search.abb.com/library/Download.aspx?DocumentID=2CDX405000C0037&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=-
  Site download: https://eloragrid.ai/tools/cad-library/download/mfr-abb-s2c-nt-8f74901845/abb-dd8e329ad2baf9516073
  Hosting basis: no-explicit-prohibition; publisher attribution: ABB; reviewed: 2026-11-11
  Rights review: Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown.; evidence: https://search.abb.com/library/Download.aspx?DocumentID=2CDX405000C0037&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=-
  Purpose: Original manufacturer STEP geometry; acquired: true; redistribution: unknown; SHA-256: c364de25d4729c31a42a889aa93f46eb150f54cc7b940cdcd0c16a93ae4698f0; revision: not recorded