# UL A1 3Pole Circuit Breaker

ABB UL A1 3Pole Circuit Breaker: original DWG / IGES / PDF for circuit-breaker equipment layouts. UL 2D FORMULA A1 3pole drawing.

## Equipment and file summary

Equipment / resource: UL A1 3Pole Circuit Breaker
Manufacturer: ABB
Resource type: Product
Manufacturer configuration: UL 2D FORMULA A1 3pole drawing
Manufacturer drawing identity: UL A1 3Pole Circuit Breaker
Source document: D 2201 9000-04.DWG
Source document: UL_A1_3POLE_F.IGS
Source document: D 2201 9000-04.PDF
Source-model envelope: 76.2 × 100.6 × 130 mm
2D preview basis: The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.
Listed file formats: DWG, IGES, PDF
Listed files: 3
Available previews: 3 drawing previews; 1 interactive model variants
Recorded revisions: Confirm the revision with the manufacturer
Source checked: 2026-11-11
Download access: Email registration for site downloads; official source links are also available

## Related GA references

- [Air circuit breaker](https://eloragrid.ai/objects/ga-air-circuit-breaker)
- [Moulded-case circuit breaker](https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/mfr-abb-ul-a1-3pole-circuit-breaker-5bfd653be7
Manufacturer: ABB
Entry type: Product
Part number: Not specified — select exact configuration
Category: Breakers & accessories
Formats: DWG, IGES, PDF
Market discovery: Global
Access: Direct download
Official source: https://search.abb.com/library/Download.aspx?DocumentID=D%202201%209000-04.DWG&LanguageCode=en&DocumentPartId=&Action=Launch
Manufacturer evidence: https://search.abb.com/library/Download.aspx?DocumentID=D%202201%209000-04.DWG&LanguageCode=en&DocumentPartId=&Action=Launch
Source checked: 2026-11-11

Inspected originals are available from this website through the existing download email prompt.
Manufacturer source discovery; confirm the exact regional equipment configuration and certification separately.
UL 2D FORMULA A1 3pole drawing


## In plain English

### What the equipment does

A circuit breaker opens and closes a power circuit and can interrupt it when its protection or trip system responds to a fault.

### A simple example

Use D 2201 9000-04.DWG.dwg to insert the supplied editable drawing into your layout.

### What the drawings help you do

Use D 2201 9000-04.DWG.dwg to insert the supplied editable drawing into your layout. Use UL_A1_3POLE_F.IGS.igs to place the original solid geometry in your 3D assembly. Use D 2201 9000-04.PDF.pdf to read the original sheet, including its annotations and any marked dimensions. The selected drawing sheet is page 1.

### Before using this reference

- Match the recorded manufacturer configuration: UL 2D FORMULA A1 3pole drawing
- The supplied model has approximate X × Y × Z bounds of 76.2 × 100.6 × 130 mm. These are source-model axes; mounting holes and installation clearances must come from the matching manufacturer sheet.
- The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.
- The source was checked on 2026-11-11. Use Documentation & sources to check for a newer issue.

### Which original files are supplied for UL A1 3Pole Circuit Breaker?

3 inspected originals for ABB UL A1 3Pole Circuit Breaker: D 2201 9000-04.DWG.dwg (DWG); UL_A1_3POLE_F.IGS.igs (IGES); D 2201 9000-04.PDF.pdf (PDF). The manufacturer describes this configuration as UL 2D FORMULA A1 3pole drawing.

### Where did these ABB files come from?

ABB supplied the original files through https://search.abb.com/library/Download.aspx?DocumentID=D%202201%209000-04.DWG&LanguageCode=en&DocumentPartId=&Action=Launch. The source reference, revision, original bytes and checksum are retained with each download.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Identify UL A1 3Pole Circuit Breaker → Choose DWG or IGES or PDF → Check the matching source configuration
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [ABB official source](https://search.abb.com/library/Download.aspx?DocumentID=D%202201%209000-04.DWG&LanguageCode=en&DocumentPartId=&Action=Launch)


## Which file should I choose?

Use D 2201 9000-04.DWG.dwg to insert the supplied editable drawing into your layout. Use UL_A1_3POLE_F.IGS.igs to place the original solid geometry in your 3D assembly. Use D 2201 9000-04.PDF.pdf to read the original sheet, including its annotations and any marked dimensions. The selected drawing sheet is page 1.

## Official files

- D 2201 9000-04.DWG.dwg (DWG): https://search.abb.com/library/Download.aspx?DocumentID=D%202201%209000-04.DWG&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=-
  Site download: https://eloragrid.ai/tools/cad-library/download/mfr-abb-ul-a1-3pole-circuit-breaker-5bfd653be7/abb-73ee7f68a32bdff3680c
  Hosting basis: no-explicit-prohibition; publisher attribution: ABB; reviewed: 2026-11-11
  Rights review: Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown.; evidence: https://search.abb.com/library/Download.aspx?DocumentID=D%202201%209000-04.DWG&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=-
  Purpose: Original manufacturer DWG geometry; acquired: true; redistribution: unknown; SHA-256: a7bcfcd328a54613088b3efe2c60209128fa035d125e6606d672858aafd2435b; revision: not recorded
- UL_A1_3POLE_F.IGS.igs (IGES): https://search.abb.com/library/Download.aspx?DocumentID=UL_A1_3POLE_F.IGS&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=-
  Site download: https://eloragrid.ai/tools/cad-library/download/mfr-abb-ul-a1-3pole-circuit-breaker-5bfd653be7/abb-2786182d1de48ea0fa82
  Hosting basis: no-explicit-prohibition; publisher attribution: ABB; reviewed: 2026-11-11
  Rights review: Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown.; evidence: https://search.abb.com/library/Download.aspx?DocumentID=UL_A1_3POLE_F.IGS&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=-
  Purpose: Original manufacturer IGES geometry; acquired: true; redistribution: unknown; SHA-256: bcf4b0cd3fd0278ec71bf594a56d3c7da1a7c5792048abc70b0f9b19b42fbc89; revision: not recorded
- D 2201 9000-04.PDF.pdf (PDF): https://search.abb.com/library/Download.aspx?DocumentID=D%202201%209000-04.PDF&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=-
  Site download: https://eloragrid.ai/tools/cad-library/download/mfr-abb-ul-a1-3pole-circuit-breaker-5bfd653be7/abb-699a22738b7c6e1624a6
  Hosting basis: no-explicit-prohibition; publisher attribution: ABB; reviewed: 2026-11-11
  Rights review: Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown.; evidence: https://search.abb.com/library/Download.aspx?DocumentID=D%202201%209000-04.PDF&LanguageCode=en&DocumentPartId=&Action=Launch&DocumentRevisionId=-
  Purpose: Original manufacturer drawing sheet; acquired: true; redistribution: unknown; SHA-256: a81bc2f68e2d71fb1713b584ac3355fdd270768243dd492fc6b63b694a791846; revision: not recorded

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.