# Acti9 Pro Vigi iC65 ELE 2P 40A 30mA A

Schneider Electric Acti9 Pro Vigi iC65 ELE 2P 40A 30mA A: original DXF / STEP for circuit-breaker equipment layouts.

## Equipment and file summary

Equipment / resource: Acti9 Pro Vigi iC65 ELE 2P 40A 30mA A
Manufacturer: Schneider Electric
Resource type: Product
Manufacturer drawing identity: Acti9 Pro Vigi iC65 ELE 2P 40A 30mA A
Named pole configuration: 2P
Source document: SB115460_3D-CAD; revision 1.0
Source-model envelope: 71.2 × 100.1 × 73.4 mm
2D preview basis: The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.
Listed file formats: DXF, STEP
Listed files: 2
Available previews: 2 drawing previews; 1 interactive model variants
Recorded revisions: 1.0
Source checked: 2026-11-11
Download access: Email registration for site downloads; official source links are also available

## Related GA references

- [Air circuit breaker](https://eloragrid.ai/objects/ga-air-circuit-breaker)
- [Moulded-case circuit breaker](https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/mfr-schneider-electric-acti9-pro-vigi-ic65-ele-2p-40a-30ma-a-405bca9933
Manufacturer: Schneider Electric
Entry type: Product
Part number: Not specified — select exact configuration
Category: Breakers & accessories
Formats: DXF, STEP
Market discovery: Global
Access: Direct download
Official source: https://www.se.com/us/en/download/document/SB115460_3D-CAD/
Manufacturer evidence: https://www.se.com/us/en/download/document/SB115460_3D-CAD/
Source checked: 2026-11-11

Inspected originals are available from this website through the existing download email prompt.
Manufacturer source discovery; confirm the exact regional equipment configuration and certification separately.
Use the manufacturer configuration named Acti9 Pro Vigi iC65 ELE 2P 40A 30mA A.


## In plain English

### What the equipment does

A circuit breaker opens and closes a power circuit and can interrupt it when its protection or trip system responds to a fault.

### A simple example

Use SB115460_3D-simplified_2D-front.dxf (revision 1.0) to insert the supplied editable drawing into your layout.

### What the drawings help you do

Use SB115460_3D-simplified_2D-front.dxf (revision 1.0) to insert the supplied editable drawing into your layout. Use SB115460_3D-simplified.stp (revision 1.0) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified SB115460_3D-simplified.stp.

### Before using this reference

- Match Schneider Electric Acti9 Pro Vigi iC65 ELE 2P 40A 30mA A and the exact source filename shown above.
- Named pole configuration: 2P
- The supplied model has approximate X × Y × Z bounds of 71.2 × 100.1 × 73.4 mm. These are source-model axes; mounting holes and installation clearances must come from the matching manufacturer sheet.
- The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.
- The source was checked on 2026-11-11; recorded file revisions: SB115460_3D-simplified_2D-front.dxf — 1.0; SB115460_3D-simplified.stp — 1.0. Use Documentation & sources to check for a newer issue.

### Which original files are supplied for Acti9 Pro Vigi iC65 ELE 2P 40A 30mA A?

2 inspected originals for Schneider Electric Acti9 Pro Vigi iC65 ELE 2P 40A 30mA A: SB115460_3D-simplified_2D-front.dxf (DXF); SB115460_3D-simplified.stp (STEP).

### Where did these Schneider Electric files come from?

Schneider Electric supplied the original files through https://www.se.com/us/en/download/document/SB115460_3D-CAD/. The source reference, revision, original bytes and checksum are retained with each download.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Identify Acti9 Pro Vigi iC65 ELE 2P 40A 30mA A → Choose DXF or STEP → Check the matching source configuration
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [Schneider Electric official source](https://www.se.com/us/en/download/document/SB115460_3D-CAD/)


## Which file should I choose?

Use SB115460_3D-simplified_2D-front.dxf (revision 1.0) to insert the supplied editable drawing into your layout. Use SB115460_3D-simplified.stp (revision 1.0) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified SB115460_3D-simplified.stp.

## Official files

- SB115460_3D-simplified_2D-front.dxf (DXF): https://download.se.com/files?p_File_Name=SB115460_3D-simplified_2D-front.dxf&p_Doc_Ref=SB115460_3D-CAD&p_enDocType=CAD
  Site download: https://eloragrid.ai/tools/cad-library/download/mfr-schneider-electric-acti9-pro-vigi-ic65-ele-2p-40a-30ma-a-405bca9933/se-845e501f1f5b570f95d0
  Hosting basis: no-explicit-prohibition; publisher attribution: Schneider Electric; reviewed: 2026-11-11
  Rights review: Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown.; evidence: https://download.se.com/files?p_File_Name=SB115460_3D-simplified_2D-front.dxf&p_Doc_Ref=SB115460_3D-CAD&p_enDocType=CAD
  Purpose: Original manufacturer DXF geometry; acquired: true; redistribution: unknown; SHA-256: e9fd3e2579f1ed11e0ddd1317fb3dbb9ecce85e445c6ce473517139e5a82e6f4; revision: 1.0
- SB115460_3D-simplified.stp (STEP): https://download.se.com/files?p_File_Name=SB115460_3D-simplified.stp&p_Doc_Ref=SB115460_3D-CAD&p_enDocType=CAD
  Site download: https://eloragrid.ai/tools/cad-library/download/mfr-schneider-electric-acti9-pro-vigi-ic65-ele-2p-40a-30ma-a-405bca9933/se-98b0c9ca49569c688e90
  Hosting basis: no-explicit-prohibition; publisher attribution: Schneider Electric; reviewed: 2026-11-11
  Rights review: Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown.; evidence: https://download.se.com/files?p_File_Name=SB115460_3D-simplified.stp&p_Doc_Ref=SB115460_3D-CAD&p_enDocType=CAD
  Purpose: Original manufacturer STEP geometry; acquired: true; redistribution: unknown; SHA-256: bce3ba5f103035c9eddde82fb1ca77dee5cc20ef2fef801849ed75fabce5a815; revision: 1.0

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.