# Climasys CU Cond. fan CU 350-600W

Schneider Electric Climasys CU Cond. fan CU 350-600W: original DXF / STEP for enclosure temperature-control equipment layouts.

## Equipment and file summary

Equipment / resource: Climasys CU Cond. fan CU 350-600W
Manufacturer: Schneider Electric
Resource type: Product
Manufacturer drawing identity: Climasys CU Cond. fan CU 350-600W
Source document: NSYCUSP001DG_3D-CAD; revision V0
Source-model envelope: 326 × 119.5 × 25.5 mm
2D preview basis: The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.
Listed file formats: DXF, STEP
Listed files: 2
Available previews: 2 drawing previews; 1 interactive model variants
Recorded revisions: V0
Source checked: 2026-11-11
Download access: Email registration for site downloads; official source links are also available

## Related GA references

- [Enclosure filter fan](https://eloragrid.ai/objects/ga-enclosure-filter-fan)
- [Enclosure air conditioner](https://eloragrid.ai/objects/ga-enclosure-air-conditioner)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/mfr-schneider-electric-climasys-cu-cond-fan-cu-350-600w-ead55179d5
Manufacturer: Schneider Electric
Entry type: Product
Part number: Not specified — select exact configuration
Category: Thermal management
Formats: DXF, STEP
Market discovery: Global
Access: Direct download
Official source: https://www.se.com/us/en/download/document/NSYCUSP001DG_3D-CAD/
Manufacturer evidence: https://www.se.com/us/en/download/document/NSYCUSP001DG_3D-CAD/
Source checked: 2026-11-11

Inspected originals are available from this website through the existing download email prompt.
Manufacturer source discovery; confirm the exact regional equipment configuration and certification separately.
Use the manufacturer configuration named Climasys CU Cond. fan CU 350-600W.


## In plain English

### What the equipment does

A fan moves air. In an electrical installation it can supply cooler air, exhaust warm air or support another planned ventilation duty.

### A simple example

Use NSYCUSP001DG_2D-front.dxf (revision V0) to insert the supplied editable drawing into your layout.

### What the drawings help you do

Use NSYCUSP001DG_2D-front.dxf (revision V0) to insert the supplied editable drawing into your layout. Use NSYCUSP001DG_3D-simplified.stp (revision V0) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified NSYCUSP001DG_3D-simplified.stp.

### Before using this reference

- Match Schneider Electric Climasys CU Cond. fan CU 350-600W and the exact source filename shown above.
- The supplied model has approximate X × Y × Z bounds of 326 × 119.5 × 25.5 mm. These are source-model axes; mounting holes and installation clearances must come from the matching manufacturer sheet.
- The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.
- The source was checked on 2026-11-11; recorded file revisions: NSYCUSP001DG_2D-front.dxf — V0; NSYCUSP001DG_3D-simplified.stp — V0. Use Documentation & sources to check for a newer issue.

### Which original files are supplied for Climasys CU Cond. fan CU 350-600W?

2 inspected originals for Schneider Electric Climasys CU Cond. fan CU 350-600W: NSYCUSP001DG_2D-front.dxf (DXF); NSYCUSP001DG_3D-simplified.stp (STEP).

### Where did these Schneider Electric files come from?

Schneider Electric supplied the original files through https://www.se.com/us/en/download/document/NSYCUSP001DG_3D-CAD/. The source reference, revision, original bytes and checksum are retained with each download.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Identify Climasys CU Cond. fan CU 350-600W → Choose DXF or STEP → Check the matching source configuration
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [Schneider Electric official source](https://www.se.com/us/en/download/document/NSYCUSP001DG_3D-CAD/)


## Which file should I choose?

Use NSYCUSP001DG_2D-front.dxf (revision V0) to insert the supplied editable drawing into your layout. Use NSYCUSP001DG_3D-simplified.stp (revision V0) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified NSYCUSP001DG_3D-simplified.stp.

## Official files

- NSYCUSP001DG_2D-front.dxf (DXF): https://download.se.com/files?p_File_Name=NSYCUSP001DG_2D-front.dxf&p_Doc_Ref=NSYCUSP001DG_3D-CAD&p_enDocType=CAD
  Site download: https://eloragrid.ai/tools/cad-library/download/mfr-schneider-electric-climasys-cu-cond-fan-cu-350-600w-ead55179d5/se-a85c7231578bbb5c40fc
  Hosting basis: no-explicit-prohibition; publisher attribution: Schneider Electric; reviewed: 2026-11-11
  Rights review: Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown.; evidence: https://download.se.com/files?p_File_Name=NSYCUSP001DG_2D-front.dxf&p_Doc_Ref=NSYCUSP001DG_3D-CAD&p_enDocType=CAD
  Purpose: Original manufacturer DXF geometry; acquired: true; redistribution: unknown; SHA-256: ca63c9a90197df9e191d15be10593820e4377eda2bd446346a5a1f75db6af129; revision: V0
- NSYCUSP001DG_3D-simplified.stp (STEP): https://download.se.com/files?p_File_Name=NSYCUSP001DG_3D-simplified.stp&p_Doc_Ref=NSYCUSP001DG_3D-CAD&p_enDocType=CAD
  Site download: https://eloragrid.ai/tools/cad-library/download/mfr-schneider-electric-climasys-cu-cond-fan-cu-350-600w-ead55179d5/se-c002e67380aa972e7869
  Hosting basis: no-explicit-prohibition; publisher attribution: Schneider Electric; reviewed: 2026-11-11
  Rights review: Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown.; evidence: https://download.se.com/files?p_File_Name=NSYCUSP001DG_3D-simplified.stp&p_Doc_Ref=NSYCUSP001DG_3D-CAD&p_enDocType=CAD
  Purpose: Original manufacturer STEP geometry; acquired: true; redistribution: unknown; SHA-256: 6616b0a42a8516844c9cf23414a594f8f020ea800474a9ea4ecfe4a8a2dcd7d9; revision: V0

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.