# CONTACTOR 4P-2F 2O

Schneider Electric CONTACTOR 4P-2F 2O: original DXF / STEP for motor-control or operating equipment layouts. CONTACTOR 4P-2F 2O EN.

## Equipment and file summary

Equipment / resource: CONTACTOR 4P-2F 2O
Manufacturer: Schneider Electric
Resource type: Product
Manufacturer configuration: CONTACTOR 4P-2F 2O EN
Manufacturer drawing identity: CONTACTOR 4P-2F 2O
Named pole configuration: 4P
Source document: LC1D400086BWS207-CAD; revision 00
Source-model envelope: 84.5 × 126.5 × 171.1 mm
2D preview basis: The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.
Listed file formats: DXF, STEP
Listed files: 2
Available previews: 2 drawing previews; 1 interactive model variants
Recorded revisions: 00
Source checked: 2026-11-11
Download access: Email registration for site downloads; official source links are also available

## Related GA references

- [PLC CPU module](https://eloragrid.ai/objects/ga-plc-cpu-module)
- [HMI touchscreen](https://eloragrid.ai/objects/ga-hmi-touchscreen)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/mfr-schneider-electric-contactor-4p-2f-2o-9b5465ef96
Manufacturer: Schneider Electric
Entry type: Product
Part number: Not specified — select exact configuration
Category: Automation & controls
Formats: DXF, STEP
Market discovery: Global
Access: Direct download
Official source: https://www.se.com/us/en/download/document/LC1D400086BWS207-CAD/
Manufacturer evidence: https://www.se.com/us/en/download/document/LC1D400086BWS207-CAD/
Source checked: 2026-11-11

Inspected originals are available from this website through the existing download email prompt.
Manufacturer source discovery; confirm the exact regional equipment configuration and certification separately.
CONTACTOR 4P-2F 2O EN


## In plain English

### What the equipment does

A contactor is an electrically operated switch. A small control signal operates its mechanism to switch a separate power circuit.

### A simple example

Use LC1D400086BWS207_2D-front.dxf (revision 00) to insert the supplied editable drawing into your layout.

### What the drawings help you do

Use LC1D400086BWS207_2D-front.dxf (revision 00) to insert the supplied editable drawing into your layout. Use LC1D400086BWS207_3D-simplified.stp (revision 00) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified LC1D400086BWS207_3D-simplified.stp.

### Before using this reference

- Match the recorded manufacturer configuration: CONTACTOR 4P-2F 2O EN
- Named pole configuration: 4P
- The supplied model has approximate X × Y × Z bounds of 84.5 × 126.5 × 171.1 mm. These are source-model axes; mounting holes and installation clearances must come from the matching manufacturer sheet.
- The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.
- The source was checked on 2026-11-11; recorded file revisions: LC1D400086BWS207_2D-front.dxf — 00; LC1D400086BWS207_3D-simplified.stp — 00. Use Documentation & sources to check for a newer issue.

### Which original files are supplied for CONTACTOR 4P-2F 2O?

2 inspected originals for Schneider Electric CONTACTOR 4P-2F 2O: LC1D400086BWS207_2D-front.dxf (DXF); LC1D400086BWS207_3D-simplified.stp (STEP). The manufacturer describes this configuration as CONTACTOR 4P-2F 2O EN.

### Where did these Schneider Electric files come from?

Schneider Electric supplied the original files through https://www.se.com/us/en/download/document/LC1D400086BWS207-CAD/. The source reference, revision, original bytes and checksum are retained with each download.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Identify CONTACTOR 4P-2F 2O → Choose DXF or STEP → Check the matching source configuration
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [Schneider Electric official source](https://www.se.com/us/en/download/document/LC1D400086BWS207-CAD/)


## Which file should I choose?

Use LC1D400086BWS207_2D-front.dxf (revision 00) to insert the supplied editable drawing into your layout. Use LC1D400086BWS207_3D-simplified.stp (revision 00) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified LC1D400086BWS207_3D-simplified.stp.

## Official files

- LC1D400086BWS207_2D-front.dxf (DXF): https://download.se.com/files?p_File_Name=LC1D400086BWS207_2D-front.dxf&p_Doc_Ref=LC1D400086BWS207-CAD&p_enDocType=CAD
  Site download: https://eloragrid.ai/tools/cad-library/download/mfr-schneider-electric-contactor-4p-2f-2o-9b5465ef96/se-2638f6f7a13185c573d8
  Hosting basis: no-explicit-prohibition; publisher attribution: Schneider Electric; reviewed: 2026-11-11
  Rights review: Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown.; evidence: https://download.se.com/files?p_File_Name=LC1D400086BWS207_2D-front.dxf&p_Doc_Ref=LC1D400086BWS207-CAD&p_enDocType=CAD
  Purpose: Original manufacturer DXF geometry; acquired: true; redistribution: unknown; SHA-256: d5e22a933eba52360806335196222f25f6595a08a3997271e2abc806eb37dcaa; revision: 00
- LC1D400086BWS207_3D-simplified.stp (STEP): https://download.se.com/files?p_File_Name=LC1D400086BWS207_3D-simplified.stp&p_Doc_Ref=LC1D400086BWS207-CAD&p_enDocType=CAD
  Site download: https://eloragrid.ai/tools/cad-library/download/mfr-schneider-electric-contactor-4p-2f-2o-9b5465ef96/se-a20075e9d0788cd8487f
  Hosting basis: no-explicit-prohibition; publisher attribution: Schneider Electric; reviewed: 2026-11-11
  Rights review: Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown.; evidence: https://download.se.com/files?p_File_Name=LC1D400086BWS207_3D-simplified.stp&p_Doc_Ref=LC1D400086BWS207-CAD&p_enDocType=CAD
  Purpose: Original manufacturer STEP geometry; acquired: true; redistribution: unknown; SHA-256: 413ac05c17c7ced03bc335be29e14100b9612de2cb8f8d1508fe894d6d06a6b6; revision: 00

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.