{"id":"mfr-schneider-electric-enerlin-x-if-ife-ethernet-com-modbus-tcp-ip-2dfb9b61ab","name":"Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP","manufacturer":"Schneider Electric","category":"communications","description":"Schneider Electric Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP: original DXF / STEP for industrial communication equipment layouts.","equipment":["industrial communication equipment","Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP"],"keywords":["Schneider Electric","Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP","MCADPD0004777_3D-CAD"],"markets":["Global"],"marketNote":"Manufacturer source discovery; confirm the exact regional equipment configuration and certification separately.","kind":"product","sourceUrl":"https://www.se.com/us/en/download/document/MCADPD0004777_3D-CAD/","officialEvidenceUrl":"https://www.se.com/us/en/download/document/MCADPD0004777_3D-CAD/","sourcePublisher":"Schneider Electric","formats":["DXF","STEP"],"availability":"direct","accessNote":"Inspected originals are available from this website through the existing download email prompt.","checkedAt":"2026-11-11","files":[{"id":"se-c93ce6dca622ce22312a","name":"MCADPD0004777_2D-front.dxf","format":"DXF","purpose":"Original manufacturer DXF geometry","url":"https://download.se.com/files?p_File_Name=MCADPD0004777_2D-front.dxf&p_Doc_Ref=MCADPD0004777_3D-CAD&p_enDocType=CAD","availability":"direct","bytes":29886,"sha256":"c076ec9032a2c93e30a82aa51a8600153e650b8ab9b74d83817419ef35f6cbaf","retrievedAt":"2026-11-11T06:39:31.530013+00:00","sourceCheckedAt":"2026-11-11","validation":"signature-checked","filenameBasis":"manufacturer-metadata","hosted":true,"redistribution":"unknown","rightsReview":{"checkedAt":"2026-11-11","sources":["https://download.se.com/files?p_File_Name=MCADPD0004777_2D-front.dxf&p_Doc_Ref=MCADPD0004777_3D-CAD&p_enDocType=CAD"],"note":"Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-11","evidenceUrl":"https://www.se.com/us/en/download/document/MCADPD0004777_3D-CAD/","attribution":"Schneider Electric"},"delivery":{"kind":"original","format":"DXF","sha256":"c076ec9032a2c93e30a82aa51a8600153e650b8ab9b74d83817419ef35f6cbaf","bytes":29886,"includes":["MCADPD0004777_2D-front.dxf"]},"documentNumber":"MCADPD0004777_3D-CAD","latestRevisionUrl":"https://www.se.com/us/en/download/document/MCADPD0004777_3D-CAD/","publisherChecksum":{"algorithm":"md5","value":"38eae2e29c96baa6ad1238ffe37673e7"},"revision":"1.0","previewGroup":"mfr-schneider-electric-enerlin-x-if-ife-ethernet-com-modbus-tcp-ip-2dfb9b61ab","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/mfr-schneider-electric-enerlin-x-if-ife-ethernet-com-modbus-tcp-ip-2dfb9b61ab/se-c93ce6dca622ce22312a"},{"id":"se-0f74a4395a3b6b6a7f13","name":"MCADPD0004777_3D-simplified.stp","format":"STEP","purpose":"Original manufacturer STEP geometry","url":"https://download.se.com/files?p_File_Name=MCADPD0004777_3D-simplified.stp&p_Doc_Ref=MCADPD0004777_3D-CAD&p_enDocType=CAD","availability":"direct","bytes":784813,"sha256":"bcba2da13870cb9d3334268e87944c26f6fea4f427b181f7f357687ca49eb15b","retrievedAt":"2026-11-11T06:12:03.764385+00:00","sourceCheckedAt":"2026-11-11","validation":"signature-checked","filenameBasis":"manufacturer-metadata","hosted":true,"redistribution":"unknown","rightsReview":{"checkedAt":"2026-11-11","sources":["https://download.se.com/files?p_File_Name=MCADPD0004777_3D-simplified.stp&p_Doc_Ref=MCADPD0004777_3D-CAD&p_enDocType=CAD"],"note":"Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-11","evidenceUrl":"https://www.se.com/us/en/download/document/MCADPD0004777_3D-CAD/","attribution":"Schneider Electric"},"delivery":{"kind":"source-bundle","name":"MCADPD0004777_3D-simplified.stp.zip","format":"ZIP","sha256":"da15e4c5b488ff79417c85c311ea08006d2ce105552eb8e5f39a41ed08334315","bytes":148330,"includes":["MCADPD0004777_3D-simplified.stp"]},"documentNumber":"MCADPD0004777_3D-CAD","latestRevisionUrl":"https://www.se.com/us/en/download/document/MCADPD0004777_3D-CAD/","publisherChecksum":{"algorithm":"md5","value":"e67586533aa6ebc7a6013bfbf7146390"},"revision":"1.0","previewGroup":"mfr-schneider-electric-enerlin-x-if-ife-ethernet-com-modbus-tcp-ip-2dfb9b61ab","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/mfr-schneider-electric-enerlin-x-if-ife-ethernet-com-modbus-tcp-ip-2dfb9b61ab/se-0f74a4395a3b6b6a7f13"}],"fileClasses":["original manufacturer drawing or model source"],"technicalFacts":[{"label":"Manufacturer drawing identity","value":"Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP","sourceUrl":"https://www.se.com/us/en/download/document/MCADPD0004777_3D-CAD/"},{"label":"Source document","value":"MCADPD0004777_3D-CAD; revision 1.0","sourceUrl":"https://download.se.com/files?p_File_Name=MCADPD0004777_2D-front.dxf&p_Doc_Ref=MCADPD0004777_3D-CAD&p_enDocType=CAD"},{"label":"Source document","value":"MCADPD0004777_3D-CAD; revision 1.0","sourceUrl":"https://download.se.com/files?p_File_Name=MCADPD0004777_3D-simplified.stp&p_Doc_Ref=MCADPD0004777_3D-CAD&p_enDocType=CAD"},{"label":"Source-model envelope","value":"71.7 × 105.2 × 70.6 mm","sourceUrl":"https://download.se.com/files?p_File_Name=MCADPD0004777_3D-simplified.stp&p_Doc_Ref=MCADPD0004777_3D-CAD&p_enDocType=CAD"},{"label":"2D preview basis","value":"The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.","sourceUrl":"https://www.se.com/us/en/download/document/MCADPD0004777_3D-CAD/"}],"applications":["switchrooms","substations","microgrids"],"configurationNote":"Use the manufacturer configuration named Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP.","equipmentFacts":[{"label":"Equipment / resource","value":"Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP"},{"label":"Manufacturer","value":"Schneider Electric"},{"label":"Resource type","value":"Product"},{"label":"Manufacturer drawing identity","value":"Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP"},{"label":"Source document","value":"MCADPD0004777_3D-CAD; revision 1.0"},{"label":"Source-model envelope","value":"71.7 × 105.2 × 70.6 mm"},{"label":"2D preview basis","value":"The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions."},{"label":"Listed file formats","value":"DXF, STEP"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"2 drawing previews; 1 interactive model variants"},{"label":"Recorded revisions","value":"1.0"},{"label":"Source checked","value":"2026-11-11"},{"label":"Download access","value":"Email registration for site downloads; official source links are also available"}],"previewImage":"/tools/cad-library/preview/mfr-schneider-electric-enerlin-x-if-ife-ethernet-com-modbus-tcp-ip-2dfb9b61ab/se-0f74a4395a3b6b6a7f13?asset=bcba2da13870cb9d3334268e87944c26f6fea4f427b181f7f357687ca49eb15b&view=thumb&v=f70cf6a83e41ff14","relatedReferences":[{"name":"Industrial Ethernet switch","url":"https://eloragrid.ai/objects/ga-industrial-ethernet-switch"},{"name":"Communication gateway","url":"https://eloragrid.ai/objects/ga-communication-gateway"}],"fileChoiceGuidance":["Use MCADPD0004777_2D-front.dxf (revision 1.0) to insert the supplied editable drawing into your layout. Use MCADPD0004777_3D-simplified.stp (revision 1.0) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified MCADPD0004777_3D-simplified.stp."],"plainEnglish":{"title":"What the equipment does","introduction":"A communication interface helps devices exchange information. A gateway may translate between communication systems, while a transceiver sends and receives their signals.","example":"Use MCADPD0004777_2D-front.dxf (revision 1.0) to insert the supplied editable drawing into your layout.","drawings":"Use MCADPD0004777_2D-front.dxf (revision 1.0) to insert the supplied editable drawing into your layout. Use MCADPD0004777_3D-simplified.stp (revision 1.0) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified MCADPD0004777_3D-simplified.stp.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Identify Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP","Choose DXF or STEP","Check the matching source configuration"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Schneider Electric official source","url":"https://www.se.com/us/en/download/document/MCADPD0004777_3D-CAD/"}],"profileId":"gateway","checklist":["Match Schneider Electric Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP and the exact source filename shown above.","The supplied model has approximate X × Y × Z bounds of 71.7 × 105.2 × 70.6 mm. These are source-model axes; mounting holes and installation clearances must come from the matching manufacturer sheet.","The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.","The source was checked on 2026-11-11; recorded file revisions: MCADPD0004777_2D-front.dxf — 1.0; MCADPD0004777_3D-simplified.stp — 1.0. Use Documentation & sources to check for a newer issue."],"questions":[{"question":"Which original files are supplied for Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP?","answer":"2 inspected originals for Schneider Electric Enerlin'X IF - IFE-Ethernet com Modbus TCP/IP: MCADPD0004777_2D-front.dxf (DXF); MCADPD0004777_3D-simplified.stp (STEP)."},{"question":"Where did these Schneider Electric files come from?","answer":"Schneider Electric supplied the original files through https://www.se.com/us/en/download/document/MCADPD0004777_3D-CAD/. The source reference, revision, original bytes and checksum are retained with each download."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/mfr-schneider-electric-enerlin-x-if-ife-ethernet-com-modbus-tcp-ip-2dfb9b61ab"}