{"id":"mfr-schneider-electric-thermal-overload-relay-25-65a-1913e7eb40","name":"Thermal overload relay 25-65A","manufacturer":"Schneider Electric","category":"protection","description":"Schneider Electric Thermal overload relay 25-65A: original STEP for protection or metering equipment layouts. Thermal overload relay 25-65A EN.","equipment":["protection or metering equipment","Thermal overload relay 25-65A"],"keywords":["Schneider Electric","Thermal overload relay 25-65A","DPER325_CAD"],"markets":["Global"],"marketNote":"Manufacturer source discovery; confirm the exact regional equipment configuration and certification separately.","kind":"product","sourceUrl":"https://www.se.com/us/en/download/document/DPER325_CAD/","officialEvidenceUrl":"https://www.se.com/us/en/download/document/DPER325_CAD/","sourcePublisher":"Schneider Electric","formats":["STEP"],"availability":"direct","accessNote":"Inspected originals are available from this website through the existing download email prompt.","checkedAt":"2026-11-11","files":[{"id":"se-cb2a28a0f3ec493b862f","name":"DPER325_3D-simplified.stp","format":"STEP","purpose":"Original manufacturer STEP geometry","url":"https://download.se.com/files?p_Doc_Ref=DPER325_CAD&p_enDocType=CAD","availability":"direct","bytes":1529561,"sha256":"72aedc4598d180ea9053f2444727df188356657d8af6597185366fe3cea8a232","retrievedAt":"2026-11-11T06:20:57.203648+00:00","sourceCheckedAt":"2026-11-11","validation":"signature-checked","filenameBasis":"manufacturer-metadata","hosted":true,"redistribution":"unknown","rightsReview":{"checkedAt":"2026-11-11","sources":["https://download.se.com/files?p_Doc_Ref=DPER325_CAD&p_enDocType=CAD"],"note":"Public manufacturer/supplier CAD original inspected with its included notices; no explicit applicable reproduction prohibition identified. Rights remain unknown."},"hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-11","evidenceUrl":"https://www.se.com/us/en/download/document/DPER325_CAD/","attribution":"Schneider Electric"},"delivery":{"kind":"source-bundle","name":"DPER325_3D-simplified.stp.zip","format":"ZIP","sha256":"16ebc3b7cf871de161db77cc8a2408b18ec95a4ba593c13fe7497505a5b0975b","bytes":283758,"includes":["DPER325_3D-simplified.stp"]},"documentNumber":"DPER325_CAD","latestRevisionUrl":"https://www.se.com/us/en/download/document/DPER325_CAD/","publisherChecksum":{"algorithm":"md5","value":"69ce5fef00d5f9605aba7089dc6b886d"},"revision":"01","previewGroup":"mfr-schneider-electric-thermal-overload-relay-25-65a-1913e7eb40","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/mfr-schneider-electric-thermal-overload-relay-25-65a-1913e7eb40/se-cb2a28a0f3ec493b862f"}],"fileClasses":["original manufacturer drawing or model source"],"technicalFacts":[{"label":"Manufacturer configuration","value":"Thermal overload relay 25-65A EN","sourceUrl":"https://www.se.com/us/en/download/document/DPER325_CAD/"},{"label":"Manufacturer drawing identity","value":"Thermal overload relay 25-65A","sourceUrl":"https://www.se.com/us/en/download/document/DPER325_CAD/"},{"label":"Source document","value":"DPER325_CAD; revision 01","sourceUrl":"https://download.se.com/files?p_Doc_Ref=DPER325_CAD&p_enDocType=CAD"},{"label":"Source-model envelope","value":"54.9 × 86.4 × 115.7 mm","sourceUrl":"https://download.se.com/files?p_Doc_Ref=DPER325_CAD&p_enDocType=CAD"},{"label":"2D preview basis","value":"The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.","sourceUrl":"https://www.se.com/us/en/download/document/DPER325_CAD/"}],"applications":["switchgear","substations"],"configurationNote":"Thermal overload relay 25-65A EN","equipmentFacts":[{"label":"Equipment / resource","value":"Thermal overload relay 25-65A"},{"label":"Manufacturer","value":"Schneider Electric"},{"label":"Resource type","value":"Product"},{"label":"Manufacturer configuration","value":"Thermal overload relay 25-65A EN"},{"label":"Manufacturer drawing identity","value":"Thermal overload relay 25-65A"},{"label":"Source document","value":"DPER325_CAD; revision 01"},{"label":"Source-model envelope","value":"54.9 × 86.4 × 115.7 mm"},{"label":"2D preview basis","value":"The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions."},{"label":"Listed file formats","value":"STEP"},{"label":"Listed files","value":"1"},{"label":"Available previews","value":"1 drawing previews; 1 interactive model variants"},{"label":"Recorded revisions","value":"01"},{"label":"Source checked","value":"2026-11-11"},{"label":"Download access","value":"Email registration for site downloads; official source links are also available"}],"previewImage":"/tools/cad-library/preview/mfr-schneider-electric-thermal-overload-relay-25-65a-1913e7eb40/se-cb2a28a0f3ec493b862f?asset=72aedc4598d180ea9053f2444727df188356657d8af6597185366fe3cea8a232&view=thumb&v=c5a53887ea35aaef","relatedReferences":[{"name":"Protection relay IED","url":"https://eloragrid.ai/objects/ga-protection-relay-ied"},{"name":"Power quality meter","url":"https://eloragrid.ai/objects/ga-power-quality-meter"}],"fileChoiceGuidance":["Use DPER325_3D-simplified.stp (revision 01) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified DPER325_3D-simplified.stp."],"plainEnglish":{"title":"What the equipment does","introduction":"Overload protection responds when a motor is carrying excessive current for too long or heating beyond its configured limit. It can request that the motor is stopped.","example":"Use DPER325_3D-simplified.stp (revision 01) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified DPER325_3D-simplified.stp.","drawings":"Use DPER325_3D-simplified.stp (revision 01) to place the original solid geometry in your 3D assembly. The ZIP contains the unmodified DPER325_3D-simplified.stp.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Identify Thermal overload relay 25-65A","Choose STEP","Check the matching source configuration"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Schneider Electric official source","url":"https://www.se.com/us/en/download/document/DPER325_CAD/"}],"profileId":"overload","checklist":["Match the recorded manufacturer configuration: Thermal overload relay 25-65A EN","The supplied model has approximate X × Y × Z bounds of 54.9 × 86.4 × 115.7 mm. These are source-model axes; mounting holes and installation clearances must come from the matching manufacturer sheet.","The orthographic views are projected from the manufacturer 3D geometry. They are labelled separately from original dimensioned sheets and do not add manufacturer dimensions.","The source was checked on 2026-11-11; recorded file revisions: DPER325_3D-simplified.stp — 01. Use Documentation & sources to check for a newer issue."],"questions":[{"question":"Which original files are supplied for Thermal overload relay 25-65A?","answer":"1 inspected original for Schneider Electric Thermal overload relay 25-65A: DPER325_3D-simplified.stp (STEP). The manufacturer describes this configuration as Thermal overload relay 25-65A EN."},{"question":"Where did these Schneider Electric files come from?","answer":"Schneider Electric supplied the original files through https://www.se.com/us/en/download/document/DPER325_CAD/. The source reference, revision, original bytes and checksum are retained with each download."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/mfr-schneider-electric-thermal-overload-relay-25-65a-1913e7eb40"}