# 550 HUP ANSI porcelain station-post insulator

550 HUP station-post insulator from PPC Insulators. The manufacturer table lists Height (in): 45; Top BCD (in): 5; Bottom BCD (in): 5. Download the source catalogue and inspect the 550 HUP column.

## Equipment and file summary

Equipment / resource: 550 HUP ANSI porcelain station-post insulator
Manufacturer: PPC Insulators
Resource type: Product
Part number: 550 HUP
Height (in): 45
Top BCD (in): 5
Bottom BCD (in): 5
Leakage Distance (in): 125
Max Shed Diameter (in): 10
Diameter Dt (in): 6.3
Diameter Db (in): 6.3
Cantilever Strength, Upright, Pounds: 2600
Impulse Withstand, kV: 550
Listed file formats: PDF
Listed files: 1
Available previews: 1 catalogue page previews
Recorded revisions: Confirm the revision with the manufacturer
Source checked: 2026-11-03
Download access: Email registration for site downloads; official source links are also available

## Related GA references

- [Switchgear panel](https://eloragrid.ai/objects/switchgear-panel)
- [Switchboard](https://eloragrid.ai/objects/switchboard)
- [Ring main unit](https://eloragrid.ai/objects/ring-main-unit)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/ppc-insulators-550-hup
Manufacturer: PPC Insulators
Entry type: Product
Part number: 550 HUP
Category: Switchboards & switchgear
Formats: PDF
Market discovery: Global
Access: Direct download
Official source: https://ppcinsulators.com/download-area/
Manufacturer evidence: https://ppcinsulators.com/wp-content/uploads/2017/06/PPC_ANSI_Solid-Core_US-Letter-updated-LQ.pdf#page=8
Source checked: 2026-11-03

Download the verified original here. The manufacturer source is linked for revision checks; preview images are for inspection and the original drawing supplies the design dimensions.
The source table supplies the listed product values. The project insulation, mechanical loading and regional requirements must be checked for the selected installation.
Use the 550 HUP column on PDF page 8. The download is the complete catalogue, not a standalone DWG or STEP part.


## In plain English

### What the equipment does

A station-post insulator supports an energised conductor while separating it electrically from its grounded support. Its end fittings, height and mechanical strength determine how it can be mounted.

### A simple example

When positioning 550 HUP on a substation support, use PDF page 8 to compare its mounting interfaces with the structure and conductor connection. The listed Height (in) is 45.

### What the drawings help you do

Download PPC_ANSI_Solid-Core_US-Letter-updated-LQ.pdf and open PDF page 8. Find the 550 HUP column; other tables and model rows or columns describe different insulators. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model.

### Before using this reference

- For 550 HUP, the source records Height (in): 45. Match that value to the conductor-support arrangement.
- Compare the 550 HUP column on PDF page 8 with the exact fixing or stud arrangement shown in the catalogue; use the dimensions for this exact reference.
- The source also lists Top BCD (in): 5. Check the project requirement against the manufacturer’s specified units and conditions.
- BCD or PCD is the diameter of the circle through the fixing-hole centres. Compare both top and bottom fixing patterns with the supporting structure and conductor fitting.
- Leakage distance follows the insulating surface. It is different from the overall height; use the height value for the physical layout.

### Where is the 550 HUP information in this download?

Open PDF page 8 of PPC_ANSI_Solid-Core_US-Letter-updated-LQ.pdf and find the 550 HUP column. The page preview preserves the manufacturer table; the download contains the complete catalogue.

### Is an editable CAD model included for 550 HUP?

This entry provides the manufacturer PDF reference and its model-specific values. A DWG, DXF or STEP model is not attached; request the exact model and preferred format here.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Identify the support position → Match the named reference and fixing → Coordinate the structure and conductor
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [PPC Insulators official source](https://ppcinsulators.com/wp-content/uploads/2017/06/PPC_ANSI_Solid-Core_US-Letter-updated-LQ.pdf#page=8)


## Which file should I choose?

Download PPC_ANSI_Solid-Core_US-Letter-updated-LQ.pdf and open PDF page 8. Find the 550 HUP column; other tables and model rows or columns describe different insulators. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model.

## Official files

- PPC_ANSI_Solid-Core_US-Letter-updated-LQ.pdf (PDF): https://ppcinsulators.com/wp-content/uploads/2017/06/PPC_ANSI_Solid-Core_US-Letter-updated-LQ.pdf
  Site download: https://eloragrid.ai/tools/cad-library/download/ppc-insulators-550-hup/catalogue
  Hosting basis: no-explicit-prohibition; publisher attribution: PPC Insulators; reviewed: 2026-11-03
  Rights review: Current manufacturer download listing and the complete catalogue text were inspected. No explicit reproduction prohibition was identified in this catalogue. Copyright remains with the named manufacturer; no redistribution licence is asserted.; evidence: https://ppcinsulators.com/download-area/, https://ppcinsulators.com/wp-content/uploads/2017/06/PPC_ANSI_Solid-Core_US-Letter-updated-LQ.pdf
  Purpose: Manufacturer catalogue with 550 HUP data and outline references on PDF page 8; acquired: true; redistribution: unknown; SHA-256: f9dc78cfecc4bbcbac11bd5d9256580b01f684540dd703298c52f7816d12b3b3; revision: not recorded

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.