{"id":"se-article-a9d07220","name":"A9D07220 — Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 20A, C curve, 10000A/15kA, AC type, 30mA","manufacturer":"Schneider Electric","category":"breakers","description":"Schneider Electric A9D07220 — Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 20A, C curve, 10000A/15kA, AC type, 30mA. Manufacturer CAD files for breakers equipment selection and layout, identified by article A9D07220.","equipment":["breakers","A9D07220 — Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 20A, C curve, 10000A/15kA, AC type, 30mA"],"keywords":["Schneider Electric","A9D07220 — Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 20A, C curve, 10000A/15kA, AC type, 30mA","A9D07220","breakers","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"A9D07220","sourceUrl":"https://www.se.com/ae/en/product/A9D07220/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-2p-20a-c-curve-10000a-15ka-ac-type-30ma/","officialEvidenceUrl":"https://www.se.com/ae/en/product/A9D07220/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-2p-20a-c-curve-10000a-15ka-ac-type-30ma/","sourcePublisher":"Schneider Electric","formats":["DXF","STEP"],"availability":"direct","accessNote":"Download the original CAD files directly from the manufacturer using the file controls. For publisher ZIPs, select the named CAD member for this equipment reference.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"A9D07220","sourceUrl":"https://www.se.com/ae/en/product/A9D07220/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-2p-20a-c-curve-10000a-15ka-ac-type-30ma/"},{"label":"Available native formats","value":"DXF / STEP","sourceUrl":"https://www.se.com/ae/en/product/A9D07220/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-2p-20a-c-curve-10000a-15ka-ac-type-30ma/"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-63c65969f919311a7d108fc8-step","name":"MCADFD0000955_3D-simplified.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADFD0000955_3D-simplified.stp&p_Doc_Ref=MCADFD0000955_3D-CAD","availability":"direct","sha256":"63c65969f919311a7d108fc8be752ab1cf9c241bdcf299230179a8b1e5073c8a","bytes":747368,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":false,"redistribution":"restricted","delivery":{"kind":"original","name":"MCADFD0000955_3D-simplified.stp","format":"STEP","sha256":"63c65969f919311a7d108fc8be752ab1cf9c241bdcf299230179a8b1e5073c8a","bytes":747368,"includes":["MCADFD0000955_3D-simplified.stp"]},"rightsReview":{"checkedAt":"2026-11-18T05:24:07.172933+00:00","sources":["https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADFD0000955_3D-simplified.stp&p_Doc_Ref=MCADFD0000955_3D-CAD","https://www.se.com/au/en/about-us/legal/terms-of-use/","https://www.se.com/us/en/about-us/legal/terms-of-use/","https://www.se.com/uk/en/about-us/legal/terms-of-use/"],"note":"Publisher redistribution restrictions are retained. This original and its derived preview are not rehosted; the download is supplied directly by the manufacturer."},"sourceCheckedAt":"2026-11-18T05:00:59.301475+00:00","previewGroup":"se-article-a9d07220"},{"id":"native-2eb34a1296ae527188f63552-dxf","name":"MCADFD0000955_2D-front.dxf","format":"DXF","purpose":"Manufacturer DXF CAD file","url":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADFD0000955_2D-front.dxf&p_Doc_Ref=MCADFD0000955_3D-CAD","availability":"direct","sha256":"2eb34a1296ae527188f6355273fc7358d2a88d766b0f55b4cf4e229ad150cadb","bytes":73194,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":false,"redistribution":"restricted","delivery":{"kind":"original","name":"MCADFD0000955_2D-front.dxf","format":"DXF","sha256":"2eb34a1296ae527188f6355273fc7358d2a88d766b0f55b4cf4e229ad150cadb","bytes":73194,"includes":["MCADFD0000955_2D-front.dxf"]},"rightsReview":{"checkedAt":"2026-11-18T05:24:07.172933+00:00","sources":["https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADFD0000955_2D-front.dxf&p_Doc_Ref=MCADFD0000955_3D-CAD","https://www.se.com/au/en/about-us/legal/terms-of-use/","https://www.se.com/us/en/about-us/legal/terms-of-use/","https://www.se.com/uk/en/about-us/legal/terms-of-use/"],"note":"Publisher redistribution restrictions are retained. This original and its derived preview are not rehosted; the download is supplied directly by the manufacturer."},"sourceCheckedAt":"2026-11-18T05:00:59.301716+00:00","previewGroup":"se-article-a9d07220"}],"artifacts":[{"id":"native-63c65969f919311a7d108fc8-step","name":"MCADFD0000955_3D-simplified.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"STEP","provenance":"manufacturer_source","sourceUrl":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADFD0000955_3D-simplified.stp&p_Doc_Ref=MCADFD0000955_3D-CAD","sourceSha256":"63c65969f919311a7d108fc8be752ab1cf9c241bdcf299230179a8b1e5073c8a","artifactSha256":"63c65969f919311a7d108fc8be752ab1cf9c241bdcf299230179a8b1e5073c8a","bytes":747368,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"official_source"},"downloadUrl":"/tools/cad-library/download/se-article-a9d07220/native-63c65969f919311a7d108fc8-step","customerPrice":0},{"id":"native-2eb34a1296ae527188f63552-dxf","name":"MCADFD0000955_2D-front.dxf","format":"DXF","purpose":"Manufacturer DXF CAD file","containedFormats":["DXF"],"downloadFormat":"DXF","provenance":"manufacturer_source","sourceUrl":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADFD0000955_2D-front.dxf&p_Doc_Ref=MCADFD0000955_3D-CAD","sourceSha256":"2eb34a1296ae527188f6355273fc7358d2a88d766b0f55b4cf4e229ad150cadb","artifactSha256":"2eb34a1296ae527188f6355273fc7358d2a88d766b0f55b4cf4e229ad150cadb","bytes":73194,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"official_source"},"downloadUrl":"/tools/cad-library/download/se-article-a9d07220/native-2eb34a1296ae527188f63552-dxf","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"A9D07220 — Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 20A, C curve, 10000A/15kA, AC type, 30mA"},{"label":"Manufacturer","value":"Schneider Electric"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"A9D07220"},{"label":"Manufacturer reference","value":"A9D07220"},{"label":"Available native formats","value":"DXF / STEP"},{"label":"Listed file formats","value":"DXF, STEP"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"relatedReferences":[{"name":"Air circuit breaker","url":"https://eloragrid.ai/objects/ga-air-circuit-breaker"},{"name":"Moulded-case circuit breaker","url":"https://eloragrid.ai/objects/ga-moulded-case-circuit-breaker"}],"fileChoiceGuidance":["Start with A9D07220. The files above belong to Schneider Electric's A9D07220 — Residual current breaker with overcurrent protection (RCBO), Acti9 iC60, 2P, 20A, C curve, 10000A/15kA, AC type, 30mA resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, DXF. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A residual-current device compares the current leaving a circuit with the current returning. A difference can indicate current flowing along an unintended path, causing the device to trip. An RCBO also provides overcurrent protection.","example":"In a substation services board, it can protect a suitable maintenance-outlet circuit by detecting a current imbalance.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Outgoing and returning current","Difference is checked","Circuit disconnects if it trips"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Schneider Electric official source","url":"https://www.se.com/ae/en/product/A9D07220/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-ic60-2p-20a-c-curve-10000a-15ka-ac-type-30ma/"}],"profileId":"rccb"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/se-article-a9d07220"}