{"id":"se-article-gv2me03","name":"GV2ME03 — Motor circuit breaker, TeSys GV2, TeSys Deca, 3P, 0.25 to 0.4A, thermal magnetic, screw clamp terminals, button control","manufacturer":"Schneider Electric","category":"wiring","description":"Schneider Electric GV2ME03 — Motor circuit breaker, TeSys GV2, TeSys Deca, 3P, 0.25 to 0.4A, thermal magnetic, screw clamp terminals, button control. Manufacturer CAD files for wiring equipment selection and layout, identified by article GV2ME03.","equipment":["wiring","GV2ME03 — Motor circuit breaker, TeSys GV2, TeSys Deca, 3P, 0.25 to 0.4A, thermal magnetic, screw clamp terminals, button control"],"keywords":["Schneider Electric","GV2ME03 — Motor circuit breaker, TeSys GV2, TeSys Deca, 3P, 0.25 to 0.4A, thermal magnetic, screw clamp terminals, button control","GV2ME03","wiring","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"GV2ME03","sourceUrl":"https://www.se.com/au/en/product/GV2ME03/motor-circuit-breaker-tesys-gv2-tesys-deca-3p-0-25-to-0-4a-thermal-magnetic-screw-clamp-terminals-button-control/","officialEvidenceUrl":"https://www.se.com/au/en/product/GV2ME03/motor-circuit-breaker-tesys-gv2-tesys-deca-3p-0-25-to-0-4a-thermal-magnetic-screw-clamp-terminals-button-control/","sourcePublisher":"Schneider Electric","formats":["DXF","STEP"],"availability":"direct","accessNote":"Download the original CAD files directly from the manufacturer using the file controls. For publisher ZIPs, select the named CAD member for this equipment reference.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"GV2ME03","sourceUrl":"https://www.se.com/au/en/product/GV2ME03/motor-circuit-breaker-tesys-gv2-tesys-deca-3p-0-25-to-0-4a-thermal-magnetic-screw-clamp-terminals-button-control/"},{"label":"Available native formats","value":"DXF / STEP","sourceUrl":"https://www.se.com/au/en/product/GV2ME03/motor-circuit-breaker-tesys-gv2-tesys-deca-3p-0-25-to-0-4a-thermal-magnetic-screw-clamp-terminals-button-control/"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-fa621c0641b9cb95a635c68a-step","name":"MCADPD0003997_3D-simplified.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003997_3D-simplified.stp&p_Doc_Ref=MCADPD0003997_3D-CAD","availability":"direct","sha256":"fa621c0641b9cb95a635c68af9e0c4063d5bc7c0de94fc4d0c95db81ba162423","bytes":3348065,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":false,"redistribution":"restricted","delivery":{"kind":"original","name":"MCADPD0003997_3D-simplified.stp","format":"STEP","sha256":"fa621c0641b9cb95a635c68af9e0c4063d5bc7c0de94fc4d0c95db81ba162423","bytes":3348065,"includes":["MCADPD0003997_3D-simplified.stp"]},"rightsReview":{"checkedAt":"2026-11-18T05:24:07.172933+00:00","sources":["https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003997_3D-simplified.stp&p_Doc_Ref=MCADPD0003997_3D-CAD","https://www.se.com/au/en/about-us/legal/terms-of-use/","https://www.se.com/us/en/about-us/legal/terms-of-use/","https://www.se.com/uk/en/about-us/legal/terms-of-use/"],"note":"Publisher redistribution restrictions are retained. This original and its derived preview are not rehosted; the download is supplied directly by the manufacturer."},"sourceCheckedAt":"2026-11-18T05:03:06.286515+00:00","previewGroup":"se-article-gv2me03"},{"id":"native-6d2b96ba66850f499bd349f1-dxf","name":"MCADPD0003997_2D-front.dxf","format":"DXF","purpose":"Manufacturer DXF CAD file","url":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003997_2D-front.dxf&p_Doc_Ref=MCADPD0003997_3D-CAD","availability":"direct","sha256":"6d2b96ba66850f499bd349f1fee89bb3019b1b731af69d152b58b23ead079352","bytes":49922,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":false,"redistribution":"restricted","delivery":{"kind":"original","name":"MCADPD0003997_2D-front.dxf","format":"DXF","sha256":"6d2b96ba66850f499bd349f1fee89bb3019b1b731af69d152b58b23ead079352","bytes":49922,"includes":["MCADPD0003997_2D-front.dxf"]},"rightsReview":{"checkedAt":"2026-11-18T05:24:07.172933+00:00","sources":["https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003997_2D-front.dxf&p_Doc_Ref=MCADPD0003997_3D-CAD","https://www.se.com/au/en/about-us/legal/terms-of-use/","https://www.se.com/us/en/about-us/legal/terms-of-use/","https://www.se.com/uk/en/about-us/legal/terms-of-use/"],"note":"Publisher redistribution restrictions are retained. This original and its derived preview are not rehosted; the download is supplied directly by the manufacturer."},"sourceCheckedAt":"2026-11-18T05:03:06.286578+00:00","previewGroup":"se-article-gv2me03"}],"artifacts":[{"id":"native-fa621c0641b9cb95a635c68a-step","name":"MCADPD0003997_3D-simplified.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"STEP","provenance":"manufacturer_source","sourceUrl":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003997_3D-simplified.stp&p_Doc_Ref=MCADPD0003997_3D-CAD","sourceSha256":"fa621c0641b9cb95a635c68af9e0c4063d5bc7c0de94fc4d0c95db81ba162423","artifactSha256":"fa621c0641b9cb95a635c68af9e0c4063d5bc7c0de94fc4d0c95db81ba162423","bytes":3348065,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"official_source"},"downloadUrl":"/tools/cad-library/download/se-article-gv2me03/native-fa621c0641b9cb95a635c68a-step","customerPrice":0},{"id":"native-6d2b96ba66850f499bd349f1-dxf","name":"MCADPD0003997_2D-front.dxf","format":"DXF","purpose":"Manufacturer DXF CAD file","containedFormats":["DXF"],"downloadFormat":"DXF","provenance":"manufacturer_source","sourceUrl":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003997_2D-front.dxf&p_Doc_Ref=MCADPD0003997_3D-CAD","sourceSha256":"6d2b96ba66850f499bd349f1fee89bb3019b1b731af69d152b58b23ead079352","artifactSha256":"6d2b96ba66850f499bd349f1fee89bb3019b1b731af69d152b58b23ead079352","bytes":49922,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"official_source"},"downloadUrl":"/tools/cad-library/download/se-article-gv2me03/native-6d2b96ba66850f499bd349f1-dxf","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"GV2ME03 — Motor circuit breaker, TeSys GV2, TeSys Deca, 3P, 0.25 to 0.4A, thermal magnetic, screw clamp terminals, button control"},{"label":"Manufacturer","value":"Schneider Electric"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"GV2ME03"},{"label":"Manufacturer reference","value":"GV2ME03"},{"label":"Available native formats","value":"DXF / STEP"},{"label":"Listed file formats","value":"DXF, STEP"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with GV2ME03. The files above belong to Schneider Electric's GV2ME03 — Motor circuit breaker, TeSys GV2, TeSys Deca, 3P, 0.25 to 0.4A, thermal magnetic, screw clamp terminals, button control resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, DXF. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A manual motor starter lets a person switch a motor locally and provides the protection functions included in the selected device.","example":"In a switchroom ventilation circuit, it can provide a local switching and protection point for a fan motor.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Operator action","Manual starter and selected protection","Motor supply switched"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Schneider Electric official source","url":"https://www.se.com/au/en/product/GV2ME03/motor-circuit-breaker-tesys-gv2-tesys-deca-3p-0-25-to-0-4a-thermal-magnetic-screw-clamp-terminals-button-control/"}],"profileId":"manual-starter"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/se-article-gv2me03"}