{"id":"se-article-gv2me053","name":"GV2ME053 — Motor circuit breaker, TeSys Deca, 3P, 0.63 to 1A, thermal magnetic, spring terminals","manufacturer":"Schneider Electric","category":"wiring","description":"Schneider Electric GV2ME053 — Motor circuit breaker, TeSys Deca, 3P, 0.63 to 1A, thermal magnetic, spring terminals. Manufacturer CAD files for wiring equipment selection and layout, identified by article GV2ME053.","equipment":["wiring","GV2ME053 — Motor circuit breaker, TeSys Deca, 3P, 0.63 to 1A, thermal magnetic, spring terminals"],"keywords":["Schneider Electric","GV2ME053 — Motor circuit breaker, TeSys Deca, 3P, 0.63 to 1A, thermal magnetic, spring terminals","GV2ME053","wiring","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"GV2ME053","sourceUrl":"https://www.se.com/au/en/product/GV2ME053/motor-circuit-breaker-tesys-deca-3p-0-63-to-1a-thermal-magnetic-spring-terminals/","officialEvidenceUrl":"https://www.se.com/au/en/product/GV2ME053/motor-circuit-breaker-tesys-deca-3p-0-63-to-1a-thermal-magnetic-spring-terminals/","sourcePublisher":"Schneider Electric","formats":["DXF","STEP"],"availability":"direct","accessNote":"Download the original CAD files directly from the manufacturer using the file controls. For publisher ZIPs, select the named CAD member for this equipment reference.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"GV2ME053","sourceUrl":"https://www.se.com/au/en/product/GV2ME053/motor-circuit-breaker-tesys-deca-3p-0-63-to-1a-thermal-magnetic-spring-terminals/"},{"label":"Available native formats","value":"DXF / STEP","sourceUrl":"https://www.se.com/au/en/product/GV2ME053/motor-circuit-breaker-tesys-deca-3p-0-63-to-1a-thermal-magnetic-spring-terminals/"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-a3e4e09bca008ef8584603ed-step","name":"MCADPD0003999_3D-simplified.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003999_3D-simplified.stp&p_Doc_Ref=MCADPD0003999_3D-CAD","availability":"direct","sha256":"a3e4e09bca008ef8584603ed0f975e19c156080ec813c877333b6e7e5d36fe10","bytes":446929,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":false,"redistribution":"restricted","delivery":{"kind":"original","name":"MCADPD0003999_3D-simplified.stp","format":"STEP","sha256":"a3e4e09bca008ef8584603ed0f975e19c156080ec813c877333b6e7e5d36fe10","bytes":446929,"includes":["MCADPD0003999_3D-simplified.stp"]},"rightsReview":{"checkedAt":"2026-11-18T05:24:07.172933+00:00","sources":["https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003999_3D-simplified.stp&p_Doc_Ref=MCADPD0003999_3D-CAD","https://www.se.com/au/en/about-us/legal/terms-of-use/","https://www.se.com/us/en/about-us/legal/terms-of-use/","https://www.se.com/uk/en/about-us/legal/terms-of-use/"],"note":"Publisher redistribution restrictions are retained. This original and its derived preview are not rehosted; the download is supplied directly by the manufacturer."},"sourceCheckedAt":"2026-11-18T05:02:11.615284+00:00","previewGroup":"se-article-gv2me053"},{"id":"native-49f06f04db494c40216b912c-dxf","name":"MCADPD0003999_2D-front.dxf","format":"DXF","purpose":"Manufacturer DXF CAD file","url":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003999_2D-front.dxf&p_Doc_Ref=MCADPD0003999_3D-CAD","availability":"direct","sha256":"49f06f04db494c40216b912c86229dae845bcc47cc52e893d9c6c036bfb688dd","bytes":47759,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":false,"redistribution":"restricted","delivery":{"kind":"original","name":"MCADPD0003999_2D-front.dxf","format":"DXF","sha256":"49f06f04db494c40216b912c86229dae845bcc47cc52e893d9c6c036bfb688dd","bytes":47759,"includes":["MCADPD0003999_2D-front.dxf"]},"rightsReview":{"checkedAt":"2026-11-18T05:24:07.172933+00:00","sources":["https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003999_2D-front.dxf&p_Doc_Ref=MCADPD0003999_3D-CAD","https://www.se.com/au/en/about-us/legal/terms-of-use/","https://www.se.com/us/en/about-us/legal/terms-of-use/","https://www.se.com/uk/en/about-us/legal/terms-of-use/"],"note":"Publisher redistribution restrictions are retained. This original and its derived preview are not rehosted; the download is supplied directly by the manufacturer."},"sourceCheckedAt":"2026-11-18T05:02:12.473973+00:00","previewGroup":"se-article-gv2me053"}],"artifacts":[{"id":"native-a3e4e09bca008ef8584603ed-step","name":"MCADPD0003999_3D-simplified.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"STEP","provenance":"manufacturer_source","sourceUrl":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003999_3D-simplified.stp&p_Doc_Ref=MCADPD0003999_3D-CAD","sourceSha256":"a3e4e09bca008ef8584603ed0f975e19c156080ec813c877333b6e7e5d36fe10","artifactSha256":"a3e4e09bca008ef8584603ed0f975e19c156080ec813c877333b6e7e5d36fe10","bytes":446929,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"official_source"},"downloadUrl":"/tools/cad-library/download/se-article-gv2me053/native-a3e4e09bca008ef8584603ed-step","customerPrice":0},{"id":"native-49f06f04db494c40216b912c-dxf","name":"MCADPD0003999_2D-front.dxf","format":"DXF","purpose":"Manufacturer DXF CAD file","containedFormats":["DXF"],"downloadFormat":"DXF","provenance":"manufacturer_source","sourceUrl":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPD0003999_2D-front.dxf&p_Doc_Ref=MCADPD0003999_3D-CAD","sourceSha256":"49f06f04db494c40216b912c86229dae845bcc47cc52e893d9c6c036bfb688dd","artifactSha256":"49f06f04db494c40216b912c86229dae845bcc47cc52e893d9c6c036bfb688dd","bytes":47759,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"official_source"},"downloadUrl":"/tools/cad-library/download/se-article-gv2me053/native-49f06f04db494c40216b912c-dxf","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"GV2ME053 — Motor circuit breaker, TeSys Deca, 3P, 0.63 to 1A, thermal magnetic, spring terminals"},{"label":"Manufacturer","value":"Schneider Electric"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"GV2ME053"},{"label":"Manufacturer reference","value":"GV2ME053"},{"label":"Available native formats","value":"DXF / STEP"},{"label":"Listed file formats","value":"DXF, STEP"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with GV2ME053. The files above belong to Schneider Electric's GV2ME053 — Motor circuit breaker, TeSys Deca, 3P, 0.63 to 1A, thermal magnetic, spring terminals resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, DXF. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A circuit breaker opens and closes a power circuit and can interrupt it when its protection or trip system responds to a fault.","example":"In a substation, the feeder breaker opens when the protection system detects a fault on the outgoing circuit.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Power circuit","Protection or trip command","Breaker interrupts current"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Schneider Electric official source","url":"https://www.se.com/au/en/product/GV2ME053/motor-circuit-breaker-tesys-deca-3p-0-63-to-1a-thermal-magnetic-spring-terminals/"}],"profileId":"breaker"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/se-article-gv2me053"}