{"id":"se-article-lv426201","name":"LV426201 — circuit breaker ComPact NSXm B (25 kA at 415 VAC), 3P 3d, 25 A rating TMD trip unit, EverLink connectors","manufacturer":"Schneider Electric","category":"wiring","description":"Schneider Electric LV426201 — circuit breaker ComPact NSXm B (25 kA at 415 VAC), 3P 3d, 25 A rating TMD trip unit, EverLink connectors. Manufacturer CAD files for wiring equipment selection and layout, identified by article LV426201.","equipment":["wiring","LV426201 — circuit breaker ComPact NSXm B (25 kA at 415 VAC), 3P 3d, 25 A rating TMD trip unit, EverLink connectors"],"keywords":["Schneider Electric","LV426201 — circuit breaker ComPact NSXm B (25 kA at 415 VAC), 3P 3d, 25 A rating TMD trip unit, EverLink connectors","LV426201","wiring","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"LV426201","sourceUrl":"https://www.se.com/au/en/product/LV426201/circuit-breaker-compact-nsxm-b-25-ka-at-415-vac-3p-3d-25-a-rating-tmd-trip-unit-everlink-connectors/","officialEvidenceUrl":"https://www.se.com/au/en/product/LV426201/circuit-breaker-compact-nsxm-b-25-ka-at-415-vac-3p-3d-25-a-rating-tmd-trip-unit-everlink-connectors/","sourcePublisher":"Schneider Electric","formats":["DXF","STEP"],"availability":"direct","accessNote":"Download the original CAD files directly from the manufacturer using the file controls. For publisher ZIPs, select the named CAD member for this equipment reference.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"LV426201","sourceUrl":"https://www.se.com/au/en/product/LV426201/circuit-breaker-compact-nsxm-b-25-ka-at-415-vac-3p-3d-25-a-rating-tmd-trip-unit-everlink-connectors/"},{"label":"Available native formats","value":"DXF / STEP","sourceUrl":"https://www.se.com/au/en/product/LV426201/circuit-breaker-compact-nsxm-b-25-ka-at-415-vac-3p-3d-25-a-rating-tmd-trip-unit-everlink-connectors/"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-1738fe70d562251667a29f0d-step","name":"MCADPP0000105_3D-simplified.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPP0000105_3D-simplified.stp&p_Doc_Ref=MCADPP0000105_3D-CAD","availability":"direct","sha256":"1738fe70d562251667a29f0dec40c2f6fc784a3771295238fc9961b1f2b885f1","bytes":751278,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":false,"redistribution":"restricted","delivery":{"kind":"original","name":"MCADPP0000105_3D-simplified.stp","format":"STEP","sha256":"1738fe70d562251667a29f0dec40c2f6fc784a3771295238fc9961b1f2b885f1","bytes":751278,"includes":["MCADPP0000105_3D-simplified.stp"]},"rightsReview":{"checkedAt":"2026-11-18T05:24:07.172933+00:00","sources":["https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPP0000105_3D-simplified.stp&p_Doc_Ref=MCADPP0000105_3D-CAD","https://www.se.com/au/en/about-us/legal/terms-of-use/","https://www.se.com/us/en/about-us/legal/terms-of-use/","https://www.se.com/uk/en/about-us/legal/terms-of-use/"],"note":"Publisher redistribution restrictions are retained. This original and its derived preview are not rehosted; the download is supplied directly by the manufacturer."},"sourceCheckedAt":"2026-11-18T05:00:44.210749+00:00","previewGroup":"se-article-lv426201"},{"id":"native-b116d6e0bab46bf0fb004a72-dxf","name":"MCADPP0000105_2D-front.dxf","format":"DXF","purpose":"Manufacturer DXF CAD file","url":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPP0000105_2D-front.dxf&p_Doc_Ref=MCADPP0000105_3D-CAD","availability":"direct","sha256":"b116d6e0bab46bf0fb004a728a0e99d8705408f0cdc9d90e7c827af1d4bc3882","bytes":22175,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":false,"redistribution":"restricted","delivery":{"kind":"original","name":"MCADPP0000105_2D-front.dxf","format":"DXF","sha256":"b116d6e0bab46bf0fb004a728a0e99d8705408f0cdc9d90e7c827af1d4bc3882","bytes":22175,"includes":["MCADPP0000105_2D-front.dxf"]},"rightsReview":{"checkedAt":"2026-11-18T05:24:07.172933+00:00","sources":["https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPP0000105_2D-front.dxf&p_Doc_Ref=MCADPP0000105_3D-CAD","https://www.se.com/au/en/about-us/legal/terms-of-use/","https://www.se.com/us/en/about-us/legal/terms-of-use/","https://www.se.com/uk/en/about-us/legal/terms-of-use/"],"note":"Publisher redistribution restrictions are retained. This original and its derived preview are not rehosted; the download is supplied directly by the manufacturer."},"sourceCheckedAt":"2026-11-18T05:00:44.210771+00:00","previewGroup":"se-article-lv426201"}],"artifacts":[{"id":"native-1738fe70d562251667a29f0d-step","name":"MCADPP0000105_3D-simplified.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"STEP","provenance":"manufacturer_source","sourceUrl":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPP0000105_3D-simplified.stp&p_Doc_Ref=MCADPP0000105_3D-CAD","sourceSha256":"1738fe70d562251667a29f0dec40c2f6fc784a3771295238fc9961b1f2b885f1","artifactSha256":"1738fe70d562251667a29f0dec40c2f6fc784a3771295238fc9961b1f2b885f1","bytes":751278,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"official_source"},"downloadUrl":"/tools/cad-library/download/se-article-lv426201/native-1738fe70d562251667a29f0d-step","customerPrice":0},{"id":"native-b116d6e0bab46bf0fb004a72-dxf","name":"MCADPP0000105_2D-front.dxf","format":"DXF","purpose":"Manufacturer DXF CAD file","containedFormats":["DXF"],"downloadFormat":"DXF","provenance":"manufacturer_source","sourceUrl":"https://download.se.com/files?p_enDocType=CAD&p_File_Name=MCADPP0000105_2D-front.dxf&p_Doc_Ref=MCADPP0000105_3D-CAD","sourceSha256":"b116d6e0bab46bf0fb004a728a0e99d8705408f0cdc9d90e7c827af1d4bc3882","artifactSha256":"b116d6e0bab46bf0fb004a728a0e99d8705408f0cdc9d90e7c827af1d4bc3882","bytes":22175,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"official_source"},"downloadUrl":"/tools/cad-library/download/se-article-lv426201/native-b116d6e0bab46bf0fb004a72-dxf","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"LV426201 — circuit breaker ComPact NSXm B (25 kA at 415 VAC), 3P 3d, 25 A rating TMD trip unit, EverLink connectors"},{"label":"Manufacturer","value":"Schneider Electric"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"LV426201"},{"label":"Manufacturer reference","value":"LV426201"},{"label":"Available native formats","value":"DXF / STEP"},{"label":"Listed file formats","value":"DXF, STEP"},{"label":"Listed files","value":"2"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with LV426201. The files above belong to Schneider Electric's LV426201 — circuit breaker ComPact NSXm B (25 kA at 415 VAC), 3P 3d, 25 A rating TMD trip unit, EverLink connectors resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, DXF. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A circuit breaker opens and closes a power circuit and can interrupt it when its protection or trip system responds to a fault.","example":"In a substation, the feeder breaker opens when the protection system detects a fault on the outgoing circuit.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Power circuit","Protection or trip command","Breaker interrupts current"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Schneider Electric official source","url":"https://www.se.com/au/en/product/LV426201/circuit-breaker-compact-nsxm-b-25-ka-at-415-vac-3p-3d-25-a-rating-tmd-trip-unit-everlink-connectors/"}],"profileId":"breaker"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/se-article-lv426201"}