{"id":"southern-states-csv-121-145-kv-84-inch-phase-spacing","name":"CSV 121–145 kV 84-inch phase spacing circuit-switcher proposal outline","manufacturer":"Southern States","category":"switchgear","description":"Southern States CSV 121–145 kV 84-inch phase spacing proposal drawing source. The drawing shows 84-inch phase spacing. The manufacturer listing identifies the 3-cycle version. Use this outline for early coordination and request a project-specific construction drawing.","equipment":["high-voltage circuit switcher","CSV 121–145 kV 84-inch phase spacing"],"keywords":["CSV","121–145 kV","84","3 cycle","switchyard","substation"],"markets":["Global"],"marketNote":"The manufacturer listing and proposal drawing are recorded separately. Confirm the specified maximum equipment voltage and project configuration directly with Southern States.","kind":"drawing","sourceUrl":"https://www.southernstatesllc.com/document-category/all-documents","officialEvidenceUrl":"https://cdn.prod.website-files.com/67cc9ac512011e36ac8ceb9a/684209a56980bdcdbb882eb3_CSV%20121kV-145kV%203-Cycle%2084in%20Phase%20Spacing%20Outline%20Drawing.pdf","sourcePublisher":"Southern States","formats":["PDF"],"availability":"request","accessNote":"Source-only. Follow the official proposal outline or request the project drawing with your email.","checkedAt":"2026-11-03","files":[{"id":"proposal-outline","name":"684209a56980bdcdbb882eb3_CSV 121kV-145kV 3-Cycle 84in Phase Spacing Outline Drawing.pdf","format":"PDF","purpose":"CSV 121–145 kV 84-inch phase spacing proposal outline. Not for construction. The manufacturer listing identifies the 3-cycle version.","url":"https://cdn.prod.website-files.com/67cc9ac512011e36ac8ceb9a/684209a56980bdcdbb882eb3_CSV%20121kV-145kV%203-Cycle%2084in%20Phase%20Spacing%20Outline%20Drawing.pdf","availability":"direct","bytes":206787,"sha256":"d01de8754772b432c62971c3e7687d3c584fb676895687eb8d00ba553545809c","retrievedAt":"2026-11-03T01:15:22.401838+00:00","validation":"signature-checked","hosted":false,"redistribution":"restricted","rightsReview":{"checkedAt":"2026-11-03","sources":["https://www.southernstatesllc.com/document-category/all-documents","https://www.southernstatesllc.com/legal/terms","https://cdn.prod.website-files.com/67cc9ac512011e36ac8ceb9a/684209a56980bdcdbb882eb3_CSV%20121kV-145kV%203-Cycle%2084in%20Phase%20Spacing%20Outline%20Drawing.pdf"],"note":"Southern States website terms section 3.2 restrict republication without written permission. This entry retains source links and an email drawing request. No original or derived preview is hosted."}}],"fileClasses":["circuit-switcher proposal outline","not for construction"],"configurationNote":"The manufacturer listing identifies the 3-cycle version.","applications":["switchyards","substations"],"technicalFacts":[{"label":"Voltage shown in drawing title","value":"121–145 kV","sourceUrl":"https://cdn.prod.website-files.com/67cc9ac512011e36ac8ceb9a/684209a56980bdcdbb882eb3_CSV%20121kV-145kV%203-Cycle%2084in%20Phase%20Spacing%20Outline%20Drawing.pdf"},{"label":"Drawing status","value":"Proposal outline — not for construction","sourceUrl":"https://cdn.prod.website-files.com/67cc9ac512011e36ac8ceb9a/684209a56980bdcdbb882eb3_CSV%20121kV-145kV%203-Cycle%2084in%20Phase%20Spacing%20Outline%20Drawing.pdf"},{"label":"Cycle version in manufacturer listing","value":"3-cycle","sourceUrl":"https://www.southernstatesllc.com/document-category/all-documents"},{"label":"Phase spacing shown","value":"84 in.","sourceUrl":"https://cdn.prod.website-files.com/67cc9ac512011e36ac8ceb9a/684209a56980bdcdbb882eb3_CSV%20121kV-145kV%203-Cycle%2084in%20Phase%20Spacing%20Outline%20Drawing.pdf"}],"equipmentFacts":[{"label":"Equipment / resource","value":"CSV 121–145 kV 84-inch phase spacing circuit-switcher proposal outline"},{"label":"Manufacturer","value":"Southern States"},{"label":"Resource type","value":"Named drawing reference"},{"label":"Voltage shown in drawing title","value":"121–145 kV"},{"label":"Drawing status","value":"Proposal outline — not for construction"},{"label":"Cycle version in manufacturer listing","value":"3-cycle"},{"label":"Phase spacing shown","value":"84 in."},{"label":"Listed file formats","value":"PDF"},{"label":"Listed files","value":"1"},{"label":"Available previews","value":"Manufacturer source / drawing request"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-03"},{"label":"Download access","value":"Use the official manufacturer source or request the exact drawing"}],"relatedReferences":[{"name":"Switchgear panel","url":"https://eloragrid.ai/objects/switchgear-panel"},{"name":"Switchboard","url":"https://eloragrid.ai/objects/switchboard"},{"name":"Ring main unit","url":"https://eloragrid.ai/objects/ring-main-unit"}],"fileChoiceGuidance":["The manufacturer listing identifies the 3-cycle version. This is a proposal PDF, not a fabrication or foundation drawing. Use the manufacturer source to inspect it; Request CAD retains your selected arrangement for follow-up."],"plainEnglish":{"title":"What the equipment does","introduction":"Switchgear groups the devices that connect, disconnect and protect power circuits. A switchboard takes an incoming supply and distributes it to outgoing circuits.","example":"For a switchyard bay using the CSV 121–145 kV 84-inch phase spacing arrangement, use the manufacturer’s proposal to discuss phase spacing and the operating arrangement, then request the project foundation, terminal and erection drawings.","drawings":"The manufacturer listing identifies the 3-cycle version. This is a proposal PDF, not a fabrication or foundation drawing. Use the manufacturer source to inspect it; Request CAD retains your selected arrangement for follow-up.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Select the proposal arrangement","Confirm the ordered equipment configuration","Obtain project-specific construction drawings"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Southern States official source","url":"https://cdn.prod.website-files.com/67cc9ac512011e36ac8ceb9a/684209a56980bdcdbb882eb3_CSV%20121kV-145kV%203-Cycle%2084in%20Phase%20Spacing%20Outline%20Drawing.pdf"}],"profileId":"switchgear","checklist":["The manufacturer listing identifies the 3-cycle version.","Match the 84-inch phase spacing; other CSV arrangements in the catalogue have different spacings.","The outline is marked not for construction. Obtain the project-specific foundation, terminal and erection drawings before detailed coordination."],"questions":[{"question":"Which CSV arrangement does this source cover?","answer":"The manufacturer listing identifies the 3-cycle version. Confirm the manufacturer’s voltage-class designation for the exact order; the listing is not used to change the drawing’s title-block value."},{"question":"Can I request the construction drawings here?","answer":"Yes. Request CAD records the CSV 121–145 kV 84-inch phase spacing arrangement and your email for our team to follow up. Availability and timing are confirmed after the manufacturer responds."}]},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/southern-states-csv-121-145-kv-84-inch-phase-spacing"}