# 1537 cap-and-pin replacement insulator

1537 cap-and-pin replacement insulator from Victor Insulators. The manufacturer table lists Height (in.): 58; Bolt circle (in.): 3; ANSI TR reference: 168. Download the source catalogue and inspect the row for 1537.

## Equipment and file summary

Equipment / resource: 1537 cap-and-pin replacement insulator
Manufacturer: Victor Insulators
Resource type: Product
Part number: 1537
Height (in.): 58
Bolt circle (in.): 3
ANSI TR reference: 168
Cantilever strength (lb): 1200
Application voltage (kV): 161
BIL (kV): 750
Base design: Pedestal
Listed file formats: PDF
Listed files: 1
Available previews: 1 catalogue page previews
Recorded revisions: Confirm the revision with the manufacturer
Source checked: 2026-11-03
Download access: Email registration for site downloads; official source links are also available

## Related GA references

- [Switchgear panel](https://eloragrid.ai/objects/switchgear-panel)
- [Switchboard](https://eloragrid.ai/objects/switchboard)
- [Ring main unit](https://eloragrid.ai/objects/ring-main-unit)

Canonical page: https://eloragrid.ai/tools/cad-library/equipment/victor-insulators-1537
Manufacturer: Victor Insulators
Entry type: Product
Part number: 1537
Category: Switchboards & switchgear
Formats: PDF
Market discovery: Global
Access: Direct download
Official source: https://www.victorinsulators.com/products/substation-products/station-posts/
Manufacturer evidence: https://www.victorinsulators.com/wp-content/uploads/2026/04/Victor-Insulators-2026-Catalog_full-Substation.pdf#page=11
Source checked: 2026-11-03

Download the verified original here. The manufacturer source is linked for revision checks; preview images are for inspection and the original drawing supplies the design dimensions.
The source table supplies the listed product values. The project insulation, mechanical loading and regional requirements must be checked for the selected installation.
Use the row for 1537 on PDF page 11. The download is the complete catalogue, not a standalone DWG or STEP part.


## In plain English

### What the equipment does

A station-post insulator supports an energised conductor while separating it electrically from its grounded support. Its end fittings, height and mechanical strength determine how it can be mounted.

### A simple example

When positioning 1537 on a substation support, use PDF page 11 to compare its mounting interfaces with the structure and conductor connection. The listed Height (in.) is 58.

### What the drawings help you do

Download Victor-Insulators-2026-Catalog_full-Substation.pdf and open PDF page 11. Find the row for 1537; other tables and model rows or columns describe different insulators. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model.

### Before using this reference

- For 1537, the source records Height (in.): 58. Match that value to the conductor-support arrangement.
- Compare the row for 1537 on PDF page 11 with the exact fixing or stud arrangement shown in the catalogue; use the dimensions for this exact reference.
- The source also lists Bolt circle (in.): 3. Check the project requirement against the manufacturer’s specified units and conditions.
- BIL or impulse withstand describes a short impulse test value. It is not the continuous operating-voltage rating.

### Where is the 1537 information in this download?

Open PDF page 11 of Victor-Insulators-2026-Catalog_full-Substation.pdf and find the row for 1537. The page preview preserves the manufacturer table; the download contains the complete catalogue.

### Is an editable CAD model included for 1537?

This entry provides the manufacturer PDF reference and its model-specific values. A DWG, DXF or STEP model is not attached; request the exact model and preferred format here.

### Terms

- CAD: Computer-aided design files used to prepare drawings and models.
- Revision: The recorded version of a drawing or model.

Concept diagram: Identify the support position → Match the named reference and fixing → Coordinate the structure and conductor
A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.

- [Victor Insulators official source](https://www.victorinsulators.com/wp-content/uploads/2026/04/Victor-Insulators-2026-Catalog_full-Substation.pdf#page=11)


## Which file should I choose?

Download Victor-Insulators-2026-Catalog_full-Substation.pdf and open PDF page 11. Find the row for 1537; other tables and model rows or columns describe different insulators. This source is a catalogue PDF. A native DWG or STEP file is not included; use Request CAD for an editable model.

## Official files

- Victor-Insulators-2026-Catalog_full-Substation.pdf (PDF): https://www.victorinsulators.com/wp-content/uploads/2026/04/Victor-Insulators-2026-Catalog_full-Substation.pdf
  Site download: https://eloragrid.ai/tools/cad-library/download/victor-insulators-1537/catalogue
  Hosting basis: no-explicit-prohibition; publisher attribution: Victor Insulators; reviewed: 2026-11-03
  Rights review: Current manufacturer download listing and the complete catalogue text were inspected. No explicit reproduction prohibition was identified in this catalogue. Copyright remains with the named manufacturer; no redistribution licence is asserted.; evidence: https://www.victorinsulators.com/products/substation-products/station-posts/, https://www.victorinsulators.com/wp-content/uploads/2026/04/Victor-Insulators-2026-Catalog_full-Substation.pdf
  Purpose: Manufacturer catalogue with 1537 data and outline references on PDF page 11; acquired: true; redistribution: unknown; SHA-256: cd4b2c7e19718be233ee6820589e786bc30f6f80eaff72afd5889943d3fad5ec; revision: not recorded

Global discovery is not proof of regional certification. Confirm exact configuration, revision, dimensional units and use rights with the manufacturer.