{"id":"weidmueller-article-1111170000","name":"HDC 64D TOLU 1M50G — Shell for rectangular connectors / Housing (industry plug-in connectors) Cable entry from top, Plug housing, End-locking clamp, lower side, Size: 8, IP65 (in plugged condition)","manufacturer":"Weidmüller","category":"wiring","description":"Weidmüller HDC 64D TOLU 1M50G — Shell for rectangular connectors / Housing (industry plug-in connectors) Cable entry from top, Plug housing, End-locking clamp, lower side, Size: 8, IP65 (in plugged condition). Manufacturer CAD files for wiring equipment selection and layout, identified by article 1111170000.","equipment":["wiring","HDC 64D TOLU 1M50G — Shell for rectangular connectors / Housing (industry plug-in connectors) Cable entry from top, Plug housing, End-locking clamp, lower side, Size: 8, IP65 (in plugged condition)"],"keywords":["Weidmüller","HDC 64D TOLU 1M50G — Shell for rectangular connectors / Housing (industry plug-in connectors) Cable entry from top, Plug housing, End-locking clamp, lower side, Size: 8, IP65 (in plugged condition)","1111170000","wiring","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1111170000","sourceUrl":"https://eshop.weidmueller.com.cn/en/hdc-64d-tolu-1m50g/p/1111170000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/hdc-64d-tolu-1m50g/p/1111170000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1111170000","sourceUrl":"https://eshop.weidmueller.com.cn/en/hdc-64d-tolu-1m50g/p/1111170000/downloads#engineering-support"},{"label":"Manufacturer type","value":"HDC 64D TOLU 1M50G","sourceUrl":"https://eshop.weidmueller.com.cn/en/hdc-64d-tolu-1m50g/p/1111170000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/hdc-64d-tolu-1m50g/p/1111170000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-b6cc8644961d025fbf113d13-zip","name":"1111170000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/13d88ad1-887b-41aa-a218-63b81353fedd/original/1111170000_DWG.zip","availability":"direct","sha256":"b6cc8644961d025fbf113d13ae82bff9148d6a1663f5406bd4153f33e9e2e58d","bytes":109027,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1111170000_DWG.zip","format":"ZIP","sha256":"b6cc8644961d025fbf113d13ae82bff9148d6a1663f5406bd4153f33e9e2e58d","bytes":109027,"includes":["1111170000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/13d88ad1-887b-41aa-a218-63b81353fedd/original/1111170000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1111170000_back.DWG","1111170000_bottom.DWG","1111170000_front.DWG","1111170000_left.DWG","1111170000_right.DWG","1111170000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1111170000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1111170000/native-b6cc8644961d025fbf113d13-zip"},{"id":"native-c3b41b64c4a155b796cb6d12-step","name":"1111170000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/3e5742eb-fda3-4c43-921e-20811bc57feb/original/1111170000.stp","availability":"direct","sha256":"c3b41b64c4a155b796cb6d125987fbb9ed416dd1953538a3f2aeb503a6a4f87b","bytes":412786,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1111170000.stp.zip","format":"ZIP","sha256":"d620013ce0a200d9a4d3cbb9e1f383127f78b0f6bb45215b48475eef8e75d7d3","bytes":90388,"includes":["1111170000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/3e5742eb-fda3-4c43-921e-20811bc57feb/original/1111170000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1111170000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1111170000/native-c3b41b64c4a155b796cb6d12-step"},{"id":"native-8a79ad5bb917bd4c469929ab-zip","name":"1111170000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/4611d98e-dc54-4573-81c6-ac304f01bbb7/original/1111170000_DXF.zip","availability":"direct","sha256":"8a79ad5bb917bd4c469929abdc673fb2dca76785b04a8ce8752115a98c8e5ce2","bytes":84669,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1111170000_DXF.zip","format":"ZIP","sha256":"8a79ad5bb917bd4c469929abdc673fb2dca76785b04a8ce8752115a98c8e5ce2","bytes":84669,"includes":["1111170000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/4611d98e-dc54-4573-81c6-ac304f01bbb7/original/1111170000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1111170000_back.DXF","1111170000_bottom.DXF","1111170000_front.DXF","1111170000_left.DXF","1111170000_right.DXF","1111170000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1111170000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1111170000/native-8a79ad5bb917bd4c469929ab-zip"}],"artifacts":[{"id":"native-b6cc8644961d025fbf113d13-zip","name":"1111170000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/13d88ad1-887b-41aa-a218-63b81353fedd/original/1111170000_DWG.zip","sourceSha256":"b6cc8644961d025fbf113d13ae82bff9148d6a1663f5406bd4153f33e9e2e58d","artifactSha256":"b6cc8644961d025fbf113d13ae82bff9148d6a1663f5406bd4153f33e9e2e58d","bytes":109027,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1111170000/native-b6cc8644961d025fbf113d13-zip","customerPrice":0},{"id":"native-c3b41b64c4a155b796cb6d12-step","name":"1111170000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/3e5742eb-fda3-4c43-921e-20811bc57feb/original/1111170000.stp","sourceSha256":"c3b41b64c4a155b796cb6d125987fbb9ed416dd1953538a3f2aeb503a6a4f87b","artifactSha256":"d620013ce0a200d9a4d3cbb9e1f383127f78b0f6bb45215b48475eef8e75d7d3","bytes":90388,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1111170000/native-c3b41b64c4a155b796cb6d12-step","customerPrice":0},{"id":"native-8a79ad5bb917bd4c469929ab-zip","name":"1111170000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/4611d98e-dc54-4573-81c6-ac304f01bbb7/original/1111170000_DXF.zip","sourceSha256":"8a79ad5bb917bd4c469929abdc673fb2dca76785b04a8ce8752115a98c8e5ce2","artifactSha256":"8a79ad5bb917bd4c469929abdc673fb2dca76785b04a8ce8752115a98c8e5ce2","bytes":84669,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1111170000/native-8a79ad5bb917bd4c469929ab-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"HDC 64D TOLU 1M50G — Shell for rectangular connectors / Housing (industry plug-in connectors) Cable entry from top, Plug housing, End-locking clamp, lower side, Size: 8, IP65 (in plugged condition)"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1111170000"},{"label":"Manufacturer reference","value":"1111170000"},{"label":"Manufacturer type","value":"HDC 64D TOLU 1M50G"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1111170000/native-b6cc8644961d025fbf113d13-zip?asset=4b8a2dd5561afb299192a5107626692a24c286352f519eb590a29aa76bb5b78d","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 1111170000. The files above belong to Weidmüller's HDC 64D TOLU 1M50G — Shell for rectangular connectors / Housing (industry plug-in connectors) Cable entry from top, Plug housing, End-locking clamp, lower side, Size: 8, IP65 (in plugged condition) resource; match any model or option suffix in the filename to your selected unit.","Available here: ZIP, STEP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A cable gland or entry system secures and seals the place where cables enter an enclosure, according to the selected product's design.","example":"In a substation marshalling cabinet, it provides an organised cable entry through the enclosure wall or gland plate.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Incoming cable","Secured and sealed entry","Enclosure wiring"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/hdc-64d-tolu-1m50g/p/1111170000/downloads#engineering-support"}],"profileId":"cable-gland"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1111170000"}