{"id":"weidmueller-article-1122910000","name":"TRZ 60VUC 1CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 1 CO contact (AgNi) , 250 V AC, 6 A, Tension-clamp connection, Test button available: No","manufacturer":"Weidmüller","category":"wiring","description":"Weidmüller TRZ 60VUC 1CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 1 CO contact (AgNi) , 250 V AC, 6 A, Tension-clamp connection, Test button available: No. Manufacturer CAD files for wiring equipment selection and layout, identified by article 1122910000.","equipment":["wiring","TRZ 60VUC 1CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 1 CO contact (AgNi) , 250 V AC, 6 A, Tension-clamp connection, Test button available: No"],"keywords":["Weidmüller","TRZ 60VUC 1CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 1 CO contact (AgNi) , 250 V AC, 6 A, Tension-clamp connection, Test button available: No","1122910000","wiring","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1122910000","sourceUrl":"https://eshop.weidmueller.com.cn/en/trz-60vuc-1co/p/1122910000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/trz-60vuc-1co/p/1122910000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1122910000","sourceUrl":"https://eshop.weidmueller.com.cn/en/trz-60vuc-1co/p/1122910000/downloads#engineering-support"},{"label":"Manufacturer type","value":"TRZ 60VUC 1CO","sourceUrl":"https://eshop.weidmueller.com.cn/en/trz-60vuc-1co/p/1122910000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/trz-60vuc-1co/p/1122910000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-dfdb476bdbf50d98b2facdf3-step","name":"1122910000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/db38b61b-c7e9-420f-ba1d-e3e701fb5f4a/original/1122910000.stp","availability":"direct","sha256":"dfdb476bdbf50d98b2facdf38000785a64a21af35b01f92fb70073c18e1c902f","bytes":1492061,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1122910000.stp.zip","format":"ZIP","sha256":"a06f47db66c437d83aad0fdece06e883f1aea7d4a786e4a8ecc10e8e0bb66430","bytes":248625,"includes":["1122910000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/db38b61b-c7e9-420f-ba1d-e3e701fb5f4a/original/1122910000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1122910000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1122910000/native-dfdb476bdbf50d98b2facdf3-step"},{"id":"native-38ce3582faf4a0df665b9fdc-zip","name":"1122910000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/7b35c624-6fdb-4179-94c3-386482ac3feb/original/1122910000_DXF.zip","availability":"direct","sha256":"38ce3582faf4a0df665b9fdcf53659f43f39cc28f8ff6fd2e362f7fc9646377e","bytes":140005,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1122910000_DXF.zip","format":"ZIP","sha256":"38ce3582faf4a0df665b9fdcf53659f43f39cc28f8ff6fd2e362f7fc9646377e","bytes":140005,"includes":["1122910000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/7b35c624-6fdb-4179-94c3-386482ac3feb/original/1122910000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1122910000_back.DXF","1122910000_bottom.DXF","1122910000_front.DXF","1122910000_left.DXF","1122910000_right.DXF","1122910000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1122910000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1122910000/native-38ce3582faf4a0df665b9fdc-zip"},{"id":"native-0212b9b4128f43a0a9ee6d82-zip","name":"1122910000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/7c8b2706-f538-4c69-b947-273af3d4480b/original/1122910000_DWG.zip","availability":"direct","sha256":"0212b9b4128f43a0a9ee6d82416576a1d9d78400e21275e15b1c12dc4c1e17d1","bytes":170366,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1122910000_DWG.zip","format":"ZIP","sha256":"0212b9b4128f43a0a9ee6d82416576a1d9d78400e21275e15b1c12dc4c1e17d1","bytes":170366,"includes":["1122910000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/7c8b2706-f538-4c69-b947-273af3d4480b/original/1122910000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1122910000_back.DWG","1122910000_bottom.DWG","1122910000_front.DWG","1122910000_left.DWG","1122910000_right.DWG","1122910000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1122910000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1122910000/native-0212b9b4128f43a0a9ee6d82-zip"}],"artifacts":[{"id":"native-dfdb476bdbf50d98b2facdf3-step","name":"1122910000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/db38b61b-c7e9-420f-ba1d-e3e701fb5f4a/original/1122910000.stp","sourceSha256":"dfdb476bdbf50d98b2facdf38000785a64a21af35b01f92fb70073c18e1c902f","artifactSha256":"a06f47db66c437d83aad0fdece06e883f1aea7d4a786e4a8ecc10e8e0bb66430","bytes":248625,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1122910000/native-dfdb476bdbf50d98b2facdf3-step","customerPrice":0},{"id":"native-38ce3582faf4a0df665b9fdc-zip","name":"1122910000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/7b35c624-6fdb-4179-94c3-386482ac3feb/original/1122910000_DXF.zip","sourceSha256":"38ce3582faf4a0df665b9fdcf53659f43f39cc28f8ff6fd2e362f7fc9646377e","artifactSha256":"38ce3582faf4a0df665b9fdcf53659f43f39cc28f8ff6fd2e362f7fc9646377e","bytes":140005,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1122910000/native-38ce3582faf4a0df665b9fdc-zip","customerPrice":0},{"id":"native-0212b9b4128f43a0a9ee6d82-zip","name":"1122910000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/7c8b2706-f538-4c69-b947-273af3d4480b/original/1122910000_DWG.zip","sourceSha256":"0212b9b4128f43a0a9ee6d82416576a1d9d78400e21275e15b1c12dc4c1e17d1","artifactSha256":"0212b9b4128f43a0a9ee6d82416576a1d9d78400e21275e15b1c12dc4c1e17d1","bytes":170366,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1122910000/native-0212b9b4128f43a0a9ee6d82-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"TRZ 60VUC 1CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 1 CO contact (AgNi) , 250 V AC, 6 A, Tension-clamp connection, Test button available: No"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1122910000"},{"label":"Manufacturer reference","value":"1122910000"},{"label":"Manufacturer type","value":"TRZ 60VUC 1CO"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 3 files / 25 MiB daily; registered free: 100 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1122910000/native-38ce3582faf4a0df665b9fdc-zip?asset=c0fad56109db520dd235303110259e85da5e0b3e99bb21ac43aa34650701d3e9","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 1122910000. The files above belong to Weidmüller's TRZ 60VUC 1CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 1 CO contact (AgNi) , 250 V AC, 6 A, Tension-clamp connection, Test button available: No resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An LED produces light when operated with the appropriate electrical current. It is commonly used to indicate an electronic device's state.","example":"On a switchgear control module, an LED can show that an input is active or that the module has power.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Electrical indication signal","LED","Visible indication"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/trz-60vuc-1co/p/1122910000/downloads#engineering-support"}],"profileId":"led"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1122910000"}