{"id":"weidmueller-article-1123640000","name":"TRZ 60VUC 2CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 2 CO contact (AgNi) , 250 V AC, 8 A, Tension-clamp connection, Test button available: No","manufacturer":"Weidmüller","category":"wiring","description":"Weidmüller TRZ 60VUC 2CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 2 CO contact (AgNi) , 250 V AC, 8 A, Tension-clamp connection, Test button available: No. Manufacturer CAD files for wiring equipment selection and layout, identified by article 1123640000.","equipment":["wiring","TRZ 60VUC 2CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 2 CO contact (AgNi) , 250 V AC, 8 A, Tension-clamp connection, Test button available: No"],"keywords":["Weidmüller","TRZ 60VUC 2CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 2 CO contact (AgNi) , 250 V AC, 8 A, Tension-clamp connection, Test button available: No","1123640000","wiring","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1123640000","sourceUrl":"https://eshop.weidmueller.com.cn/en/trz-60vuc-2co/p/1123640000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/trz-60vuc-2co/p/1123640000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1123640000","sourceUrl":"https://eshop.weidmueller.com.cn/en/trz-60vuc-2co/p/1123640000/downloads#engineering-support"},{"label":"Manufacturer type","value":"TRZ 60VUC 2CO","sourceUrl":"https://eshop.weidmueller.com.cn/en/trz-60vuc-2co/p/1123640000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/trz-60vuc-2co/p/1123640000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-3d9eb0ef85901cbb112c36e5-step","name":"1123640000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/e1014b08-9618-4d84-a43e-098b806762ab/original/1123640000.stp","availability":"direct","sha256":"3d9eb0ef85901cbb112c36e5ac106c398a420c635e340b5c2b03243f2fe208f0","bytes":1719492,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1123640000.stp.zip","format":"ZIP","sha256":"655fb02b1c709f3a56015105a2a49aea16dd25b118d0e9acf67dab3f430955c2","bytes":286324,"includes":["1123640000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/e1014b08-9618-4d84-a43e-098b806762ab/original/1123640000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1123640000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1123640000/native-3d9eb0ef85901cbb112c36e5-step"},{"id":"native-65df45a861bf1694f155ecbc-zip","name":"1123640000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/fed5b55d-9df4-4f18-b60f-3145a3365922/original/1123640000_DXF.zip","availability":"direct","sha256":"65df45a861bf1694f155ecbc128b02d466d3a9b7ab219855246a6ff189fbdbcb","bytes":140508,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1123640000_DXF.zip","format":"ZIP","sha256":"65df45a861bf1694f155ecbc128b02d466d3a9b7ab219855246a6ff189fbdbcb","bytes":140508,"includes":["1123640000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/fed5b55d-9df4-4f18-b60f-3145a3365922/original/1123640000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1123640000_back.DXF","1123640000_bottom.DXF","1123640000_front.DXF","1123640000_left.DXF","1123640000_right.DXF","1123640000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1123640000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1123640000/native-65df45a861bf1694f155ecbc-zip"},{"id":"native-7deeab0860f89ac2e2bc784c-zip","name":"1123640000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/4ceb640b-e3e9-46b9-9598-866c80067c8f/original/1123640000_DWG.zip","availability":"direct","sha256":"7deeab0860f89ac2e2bc784c7ae35f522b7bf16e029d1de0f817de24cb3cf2de","bytes":172812,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1123640000_DWG.zip","format":"ZIP","sha256":"7deeab0860f89ac2e2bc784c7ae35f522b7bf16e029d1de0f817de24cb3cf2de","bytes":172812,"includes":["1123640000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/4ceb640b-e3e9-46b9-9598-866c80067c8f/original/1123640000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1123640000_back.DWG","1123640000_bottom.DWG","1123640000_front.DWG","1123640000_left.DWG","1123640000_right.DWG","1123640000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1123640000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1123640000/native-7deeab0860f89ac2e2bc784c-zip"}],"artifacts":[{"id":"native-3d9eb0ef85901cbb112c36e5-step","name":"1123640000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/e1014b08-9618-4d84-a43e-098b806762ab/original/1123640000.stp","sourceSha256":"3d9eb0ef85901cbb112c36e5ac106c398a420c635e340b5c2b03243f2fe208f0","artifactSha256":"655fb02b1c709f3a56015105a2a49aea16dd25b118d0e9acf67dab3f430955c2","bytes":286324,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1123640000/native-3d9eb0ef85901cbb112c36e5-step","customerPrice":0},{"id":"native-65df45a861bf1694f155ecbc-zip","name":"1123640000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/fed5b55d-9df4-4f18-b60f-3145a3365922/original/1123640000_DXF.zip","sourceSha256":"65df45a861bf1694f155ecbc128b02d466d3a9b7ab219855246a6ff189fbdbcb","artifactSha256":"65df45a861bf1694f155ecbc128b02d466d3a9b7ab219855246a6ff189fbdbcb","bytes":140508,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1123640000/native-65df45a861bf1694f155ecbc-zip","customerPrice":0},{"id":"native-7deeab0860f89ac2e2bc784c-zip","name":"1123640000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/4ceb640b-e3e9-46b9-9598-866c80067c8f/original/1123640000_DWG.zip","sourceSha256":"7deeab0860f89ac2e2bc784c7ae35f522b7bf16e029d1de0f817de24cb3cf2de","artifactSha256":"7deeab0860f89ac2e2bc784c7ae35f522b7bf16e029d1de0f817de24cb3cf2de","bytes":172812,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1123640000/native-7deeab0860f89ac2e2bc784c-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"TRZ 60VUC 2CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 2 CO contact (AgNi) , 250 V AC, 8 A, Tension-clamp connection, Test button available: No"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1123640000"},{"label":"Manufacturer reference","value":"1123640000"},{"label":"Manufacturer type","value":"TRZ 60VUC 2CO"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1123640000/native-65df45a861bf1694f155ecbc-zip?asset=86e06746d21f241723b93633fb7059e3d8ae38901ac13b3d587b76e1ac006481","relatedReferences":[{"name":"Terminal strip assembly","url":"https://eloragrid.ai/objects/terminal-strip"},{"name":"Cable gland","url":"https://eloragrid.ai/objects/ga-cable-gland"}],"fileChoiceGuidance":["Start with 1123640000. The files above belong to Weidmüller's TRZ 60VUC 2CO — Standard all-or-nothing relay / Relay module, 60 V UC ±10 %, Green LED, Rectifier, 2 CO contact (AgNi) , 250 V AC, 8 A, Tension-clamp connection, Test button available: No resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An LED produces light when operated with the appropriate electrical current. It is commonly used to indicate an electronic device's state.","example":"On a switchgear control module, an LED can show that an input is active or that the module has power.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Electrical indication signal","LED","Visible indication"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/trz-60vuc-2co/p/1123640000/downloads#engineering-support"}],"profileId":"led"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1123640000"}