{"id":"weidmueller-article-1126950000","name":"TOS 24VUC 48VDC0,1A — Optocoupler (relay) / Solid-state relay, 24 V UC ±10 %, Rectifier 3... 48 V DC, 100 mA, Screw connection","manufacturer":"Weidmüller","category":"protection","description":"Weidmüller TOS 24VUC 48VDC0,1A — Optocoupler (relay) / Solid-state relay, 24 V UC ±10 %, Rectifier 3... 48 V DC, 100 mA, Screw connection. Manufacturer CAD files for protection equipment selection and layout, identified by article 1126950000.","equipment":["protection","TOS 24VUC 48VDC0,1A — Optocoupler (relay) / Solid-state relay, 24 V UC ±10 %, Rectifier 3... 48 V DC, 100 mA, Screw connection"],"keywords":["Weidmüller","TOS 24VUC 48VDC0,1A — Optocoupler (relay) / Solid-state relay, 24 V UC ±10 %, Rectifier 3... 48 V DC, 100 mA, Screw connection","1126950000","protection","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1126950000","sourceUrl":"https://eshop.weidmueller.com.cn/en/tos-24vuc-48vdc01a/p/1126950000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/tos-24vuc-48vdc01a/p/1126950000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1126950000","sourceUrl":"https://eshop.weidmueller.com.cn/en/tos-24vuc-48vdc01a/p/1126950000/downloads#engineering-support"},{"label":"Manufacturer type","value":"TOS 24VUC 48VDC0,1A","sourceUrl":"https://eshop.weidmueller.com.cn/en/tos-24vuc-48vdc01a/p/1126950000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/tos-24vuc-48vdc01a/p/1126950000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-7294b511ba9265bcce329f57-zip","name":"1126950000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/b0cd0478-9e0c-4fea-b1d1-f9d8b0b99033/original/1126950000_DWG.zip","availability":"direct","sha256":"7294b511ba9265bcce329f5739a8349be83f00911f5b90e36477a81deef8d6c7","bytes":63186,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1126950000_DWG.zip","format":"ZIP","sha256":"7294b511ba9265bcce329f5739a8349be83f00911f5b90e36477a81deef8d6c7","bytes":63186,"includes":["1126950000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/b0cd0478-9e0c-4fea-b1d1-f9d8b0b99033/original/1126950000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1126950000_back.DWG","1126950000_bottom.DWG","1126950000_front.DWG","1126950000_left.DWG","1126950000_right.DWG","1126950000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1126950000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1126950000/native-7294b511ba9265bcce329f57-zip"},{"id":"native-89620ab90b395af24d4260bb-step","name":"1126950000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/fdc6e4fe-086e-4ceb-a388-89c21d81bd49/original/1126950000.stp","availability":"direct","sha256":"89620ab90b395af24d4260bb01dfa7cba67790e8c67e9dda3e94af87e963f3e2","bytes":970003,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1126950000.stp.zip","format":"ZIP","sha256":"01df1b4df899a563fcfb441db9731f6e4d843c84fc5f9fa802c6a908372c80c8","bytes":176645,"includes":["1126950000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/fdc6e4fe-086e-4ceb-a388-89c21d81bd49/original/1126950000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1126950000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1126950000/native-89620ab90b395af24d4260bb-step"},{"id":"native-8a72f6d32442bd51fd988e1f-zip","name":"1126950000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/13581f11-8ace-463c-a507-539fd25f30bf/original/1126950000_DXF.zip","availability":"direct","sha256":"8a72f6d32442bd51fd988e1fb87f27adf049f9d77e8c88ec837ecdc386fc3e19","bytes":53227,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1126950000_DXF.zip","format":"ZIP","sha256":"8a72f6d32442bd51fd988e1fb87f27adf049f9d77e8c88ec837ecdc386fc3e19","bytes":53227,"includes":["1126950000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/13581f11-8ace-463c-a507-539fd25f30bf/original/1126950000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1126950000_back.DXF","1126950000_bottom.DXF","1126950000_front.DXF","1126950000_left.DXF","1126950000_right.DXF","1126950000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1126950000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1126950000/native-8a72f6d32442bd51fd988e1f-zip"}],"artifacts":[{"id":"native-7294b511ba9265bcce329f57-zip","name":"1126950000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/b0cd0478-9e0c-4fea-b1d1-f9d8b0b99033/original/1126950000_DWG.zip","sourceSha256":"7294b511ba9265bcce329f5739a8349be83f00911f5b90e36477a81deef8d6c7","artifactSha256":"7294b511ba9265bcce329f5739a8349be83f00911f5b90e36477a81deef8d6c7","bytes":63186,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1126950000/native-7294b511ba9265bcce329f57-zip","customerPrice":0},{"id":"native-89620ab90b395af24d4260bb-step","name":"1126950000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/fdc6e4fe-086e-4ceb-a388-89c21d81bd49/original/1126950000.stp","sourceSha256":"89620ab90b395af24d4260bb01dfa7cba67790e8c67e9dda3e94af87e963f3e2","artifactSha256":"01df1b4df899a563fcfb441db9731f6e4d843c84fc5f9fa802c6a908372c80c8","bytes":176645,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1126950000/native-89620ab90b395af24d4260bb-step","customerPrice":0},{"id":"native-8a72f6d32442bd51fd988e1f-zip","name":"1126950000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/13581f11-8ace-463c-a507-539fd25f30bf/original/1126950000_DXF.zip","sourceSha256":"8a72f6d32442bd51fd988e1fb87f27adf049f9d77e8c88ec837ecdc386fc3e19","artifactSha256":"8a72f6d32442bd51fd988e1fb87f27adf049f9d77e8c88ec837ecdc386fc3e19","bytes":53227,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1126950000/native-8a72f6d32442bd51fd988e1f-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"TOS 24VUC 48VDC0,1A — Optocoupler (relay) / Solid-state relay, 24 V UC ±10 %, Rectifier 3... 48 V DC, 100 mA, Screw connection"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1126950000"},{"label":"Manufacturer reference","value":"1126950000"},{"label":"Manufacturer type","value":"TOS 24VUC 48VDC0,1A"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1126950000/native-7294b511ba9265bcce329f57-zip?asset=19ff9355f61831d22005296bc80ff924b7accc377c853387b49c4a783c7cf91c","relatedReferences":[{"name":"Protection relay IED","url":"https://eloragrid.ai/objects/ga-protection-relay-ied"},{"name":"Power quality meter","url":"https://eloragrid.ai/objects/ga-power-quality-meter"}],"fileChoiceGuidance":["Start with 1126950000. The files above belong to Weidmüller's TOS 24VUC 48VDC0,1A — Optocoupler (relay) / Solid-state relay, 24 V UC ±10 %, Rectifier 3... 48 V DC, 100 mA, Screw connection resource; match any model or option suffix in the filename to your selected unit.","Available here: ZIP, STEP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An electrical isolator passes information or energy between circuits without a direct conducting connection across its isolation barrier.","example":"Inside a substation relay, an isolation interface can pass a measurement or command between separate electronic circuits.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Signal or energy input","Isolation barrier","Separate receiving circuit"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/tos-24vuc-48vdc01a/p/1126950000/downloads#engineering-support"}],"profileId":"isolation"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1126950000"}