{"id":"weidmueller-article-1127210000","name":"TOS 120VUC 24VDC2A — Optocoupler (relay) / Solid-state relay, 120 V UC ±10 %, Rectifier 3...33 V DC, 2 A, Screw connection","manufacturer":"Weidmüller","category":"protection","description":"Weidmüller TOS 120VUC 24VDC2A — Optocoupler (relay) / Solid-state relay, 120 V UC ±10 %, Rectifier 3...33 V DC, 2 A, Screw connection. Manufacturer CAD files for protection equipment selection and layout, identified by article 1127210000.","equipment":["protection","TOS 120VUC 24VDC2A — Optocoupler (relay) / Solid-state relay, 120 V UC ±10 %, Rectifier 3...33 V DC, 2 A, Screw connection"],"keywords":["Weidmüller","TOS 120VUC 24VDC2A — Optocoupler (relay) / Solid-state relay, 120 V UC ±10 %, Rectifier 3...33 V DC, 2 A, Screw connection","1127210000","protection","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1127210000","sourceUrl":"https://eshop.weidmueller.com.cn/en/tos-120vuc-24vdc2a/p/1127210000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/tos-120vuc-24vdc2a/p/1127210000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1127210000","sourceUrl":"https://eshop.weidmueller.com.cn/en/tos-120vuc-24vdc2a/p/1127210000/downloads#engineering-support"},{"label":"Manufacturer type","value":"TOS 120VUC 24VDC2A","sourceUrl":"https://eshop.weidmueller.com.cn/en/tos-120vuc-24vdc2a/p/1127210000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/tos-120vuc-24vdc2a/p/1127210000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-a1cd7fac15d776095e05553d-zip","name":"1127210000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/ff38953d-7873-43c0-94e0-499d5d081f55/original/1127210000_DXF.zip","availability":"direct","sha256":"a1cd7fac15d776095e05553dae3c193163304bb9c86ade9aa99148a825c2a80d","bytes":101080,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1127210000_DXF.zip","format":"ZIP","sha256":"a1cd7fac15d776095e05553dae3c193163304bb9c86ade9aa99148a825c2a80d","bytes":101080,"includes":["1127210000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/ff38953d-7873-43c0-94e0-499d5d081f55/original/1127210000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1127210000_back.DXF","1127210000_bottom.DXF","1127210000_front.DXF","1127210000_left.DXF","1127210000_right.DXF","1127210000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1127210000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1127210000/native-a1cd7fac15d776095e05553d-zip"},{"id":"native-f364ab7de5b1dbaa79b268b0-step","name":"1127210000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/01b667aa-23ae-48d8-850e-5ee3828ca7b7/original/1127210000.stp","availability":"direct","sha256":"f364ab7de5b1dbaa79b268b03ec01316da4e545d2e6f8232362fce7fbaaaebba","bytes":984478,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1127210000.stp.zip","format":"ZIP","sha256":"cf29bce4b134bdf1e74f619dcf378eb07f2d02d76acdee3a0a88b7342be15481","bytes":171364,"includes":["1127210000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/01b667aa-23ae-48d8-850e-5ee3828ca7b7/original/1127210000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1127210000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1127210000/native-f364ab7de5b1dbaa79b268b0-step"},{"id":"native-242436b110b1893ec4a45286-zip","name":"1127210000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/7244fba0-fddb-4869-8e22-43dcc26f370e/original/1127210000_DWG.zip","availability":"direct","sha256":"242436b110b1893ec4a4528677db066edad655daa705e489920f9eecdc357fba","bytes":125822,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1127210000_DWG.zip","format":"ZIP","sha256":"242436b110b1893ec4a4528677db066edad655daa705e489920f9eecdc357fba","bytes":125822,"includes":["1127210000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/7244fba0-fddb-4869-8e22-43dcc26f370e/original/1127210000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1127210000_back.DWG","1127210000_bottom.DWG","1127210000_front.DWG","1127210000_left.DWG","1127210000_right.DWG","1127210000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1127210000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1127210000/native-242436b110b1893ec4a45286-zip"}],"artifacts":[{"id":"native-a1cd7fac15d776095e05553d-zip","name":"1127210000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/ff38953d-7873-43c0-94e0-499d5d081f55/original/1127210000_DXF.zip","sourceSha256":"a1cd7fac15d776095e05553dae3c193163304bb9c86ade9aa99148a825c2a80d","artifactSha256":"a1cd7fac15d776095e05553dae3c193163304bb9c86ade9aa99148a825c2a80d","bytes":101080,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1127210000/native-a1cd7fac15d776095e05553d-zip","customerPrice":0},{"id":"native-f364ab7de5b1dbaa79b268b0-step","name":"1127210000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/01b667aa-23ae-48d8-850e-5ee3828ca7b7/original/1127210000.stp","sourceSha256":"f364ab7de5b1dbaa79b268b03ec01316da4e545d2e6f8232362fce7fbaaaebba","artifactSha256":"cf29bce4b134bdf1e74f619dcf378eb07f2d02d76acdee3a0a88b7342be15481","bytes":171364,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1127210000/native-f364ab7de5b1dbaa79b268b0-step","customerPrice":0},{"id":"native-242436b110b1893ec4a45286-zip","name":"1127210000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/7244fba0-fddb-4869-8e22-43dcc26f370e/original/1127210000_DWG.zip","sourceSha256":"242436b110b1893ec4a4528677db066edad655daa705e489920f9eecdc357fba","artifactSha256":"242436b110b1893ec4a4528677db066edad655daa705e489920f9eecdc357fba","bytes":125822,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1127210000/native-242436b110b1893ec4a45286-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"TOS 120VUC 24VDC2A — Optocoupler (relay) / Solid-state relay, 120 V UC ±10 %, Rectifier 3...33 V DC, 2 A, Screw connection"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1127210000"},{"label":"Manufacturer reference","value":"1127210000"},{"label":"Manufacturer type","value":"TOS 120VUC 24VDC2A"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1127210000/native-a1cd7fac15d776095e05553d-zip?asset=63ba42f8986edfe02c2657dc8097caa1cec4b80e0e5c7912049086ec07d0da95","relatedReferences":[{"name":"Protection relay IED","url":"https://eloragrid.ai/objects/ga-protection-relay-ied"},{"name":"Power quality meter","url":"https://eloragrid.ai/objects/ga-power-quality-meter"}],"fileChoiceGuidance":["Start with 1127210000. The files above belong to Weidmüller's TOS 120VUC 24VDC2A — Optocoupler (relay) / Solid-state relay, 120 V UC ±10 %, Rectifier 3...33 V DC, 2 A, Screw connection resource; match any model or option suffix in the filename to your selected unit.","Available here: ZIP, STEP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"An electrical isolator passes information or energy between circuits without a direct conducting connection across its isolation barrier.","example":"Inside a substation relay, an isolation interface can pass a measurement or command between separate electronic circuits.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Signal or energy input","Isolation barrier","Separate receiving circuit"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/tos-120vuc-24vdc2a/p/1127210000/downloads#engineering-support"}],"profileId":"isolation"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1127210000"}