{"id":"weidmueller-article-1283230000","name":"MOS 24VDC/8-30VDC 2A E — Optocoupler (relay) / Solid-state relay, 24 V DC ±20 %, Varistor, Reverse polarity protection, 8...30 V DC, 2 A, Screw connection","manufacturer":"Weidmüller","category":"protection","description":"Weidmüller MOS 24VDC/8-30VDC 2A E — Optocoupler (relay) / Solid-state relay, 24 V DC ±20 %, Varistor, Reverse polarity protection, 8...30 V DC, 2 A, Screw connection. Manufacturer CAD files for protection equipment selection and layout, identified by article 1283230000.","equipment":["protection","MOS 24VDC/8-30VDC 2A E — Optocoupler (relay) / Solid-state relay, 24 V DC ±20 %, Varistor, Reverse polarity protection, 8...30 V DC, 2 A, Screw connection"],"keywords":["Weidmüller","MOS 24VDC/8-30VDC 2A E — Optocoupler (relay) / Solid-state relay, 24 V DC ±20 %, Varistor, Reverse polarity protection, 8...30 V DC, 2 A, Screw connection","1283230000","protection","DWG","DXF","STEP"],"markets":["Global"],"marketNote":"Confirm regional configuration, ratings and approvals with the manufacturer.","kind":"product","partNumber":"1283230000","sourceUrl":"https://eshop.weidmueller.com.cn/en/mos-24vdc8-30vdc-2a-e/p/1283230000/downloads#engineering-support","officialEvidenceUrl":"https://eshop.weidmueller.com.cn/en/mos-24vdc8-30vdc-2a-e/p/1283230000/downloads#engineering-support","sourcePublisher":"Weidmüller","formats":["DWG","DXF","STEP"],"availability":"direct","accessNote":"Manufacturer CAD files for the listed equipment reference. Open the original files in compatible CAD software.","checkedAt":"2026-11-17T15:50:41.709187+00:00","fileClasses":["original manufacturer CAD"],"technicalFacts":[{"label":"Manufacturer reference","value":"1283230000","sourceUrl":"https://eshop.weidmueller.com.cn/en/mos-24vdc8-30vdc-2a-e/p/1283230000/downloads#engineering-support"},{"label":"Manufacturer type","value":"MOS 24VDC/8-30VDC 2A E","sourceUrl":"https://eshop.weidmueller.com.cn/en/mos-24vdc8-30vdc-2a-e/p/1283230000/downloads#engineering-support"},{"label":"Available native formats","value":"DWG / DXF / STEP","sourceUrl":"https://eshop.weidmueller.com.cn/en/mos-24vdc8-30vdc-2a-e/p/1283230000/downloads#engineering-support"}],"configurationNote":"Check the exact manufacturer article and selected configuration against the original drawing. Publisher-shared geometry and alternate formats remain on this equipment entry.","files":[{"id":"native-254355cc24d59491e867d9b2-step","name":"1283230000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","url":"https://assets.dam.weidmueller.com/assets/api/781e620e-6de3-4436-ab87-0e4391f1cd1e/original/1283230000.stp","availability":"direct","sha256":"254355cc24d59491e867d9b2bbd4150f13155cc3d1ec0dfb9025d92e9f78bffe","bytes":877326,"filenameBasis":"manufacturer-metadata","validation":"signature-checked","hosted":true,"redistribution":"unknown","delivery":{"kind":"source-bundle","name":"1283230000.stp.zip","format":"ZIP","sha256":"c657056a9d56f3f97714c47dd42f96f88d6cc7ff6b8c92c7f0f117cd882bff25","bytes":166456,"includes":["1283230000.stp"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/781e620e-6de3-4436-ab87-0e4391f1cd1e/original/1283230000.stp","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1283230000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1283230000/native-254355cc24d59491e867d9b2-step"},{"id":"native-ae2835bf5a26d506b4f0c6a1-zip","name":"1283230000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/a0292340-ab9b-43e4-ad36-870dc7a30254/original/1283230000_DWG.zip","availability":"direct","sha256":"ae2835bf5a26d506b4f0c6a12ff5ba9df33325041570efad54d49feb25c5c4fd","bytes":107528,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1283230000_DWG.zip","format":"ZIP","sha256":"ae2835bf5a26d506b4f0c6a12ff5ba9df33325041570efad54d49feb25c5c4fd","bytes":107528,"includes":["1283230000_DWG.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/a0292340-ab9b-43e4-ad36-870dc7a30254/original/1283230000_DWG.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1283230000_back.DWG","1283230000_bottom.DWG","1283230000_front.DWG","1283230000_left.DWG","1283230000_right.DWG","1283230000_top.DWG"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1283230000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1283230000/native-ae2835bf5a26d506b4f0c6a1-zip"},{"id":"native-76cc1c9915c8197daec261e8-zip","name":"1283230000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","url":"https://assets.dam.weidmueller.com/assets/api/b010034e-9b71-4d2c-acba-5064146afc1b/original/1283230000_DXF.zip","availability":"direct","sha256":"76cc1c9915c8197daec261e8da9a5779eee234f4cefb8948d34881ca376ead06","bytes":86322,"filenameBasis":"manufacturer-metadata","validation":"archive-inspected","hosted":true,"redistribution":"unknown","delivery":{"kind":"original","name":"1283230000_DXF.zip","format":"ZIP","sha256":"76cc1c9915c8197daec261e8da9a5779eee234f4cefb8948d34881ca376ead06","bytes":86322,"includes":["1283230000_DXF.zip"]},"rightsReview":{"checkedAt":"2026-11-18T04:11:33.177394+00:00","sources":["https://assets.dam.weidmueller.com/assets/api/b010034e-9b71-4d2c-acba-5064146afc1b/original/1283230000_DXF.zip","https://www.weidmueller.com/int/service/engineering_data.jsp","https://www.weidmueller.com/int/other/imprint.jsp"],"note":"Manufacturer original retained unchanged. Engineering-data terms and imprint reviewed under the existing no-explicit-prohibition policy. Copyright remains with the manufacturer; no separate written redistribution permission or explicit licence is claimed."},"archiveContents":["1283230000_back.DXF","1283230000_bottom.DXF","1283230000_front.DXF","1283230000_left.DXF","1283230000_right.DXF","1283230000_top.DXF"],"sourceCheckedAt":"2026-11-18T04:11:33.177394+00:00","hostingBasis":{"policy":"no-explicit-prohibition","checkedAt":"2026-11-18T04:11:33.177394+00:00","evidenceUrl":"https://www.weidmueller.com/int/service/engineering_data.jsp","attribution":"Weidmüller"},"previewGroup":"weidmueller-article-1283230000","downloadUrl":"https://eloragrid.ai/tools/cad-library/download/weidmueller-article-1283230000/native-76cc1c9915c8197daec261e8-zip"}],"artifacts":[{"id":"native-254355cc24d59491e867d9b2-step","name":"1283230000.stp","format":"STEP","purpose":"Manufacturer STEP CAD file","containedFormats":["STEP"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/781e620e-6de3-4436-ab87-0e4391f1cd1e/original/1283230000.stp","sourceSha256":"254355cc24d59491e867d9b2bbd4150f13155cc3d1ec0dfb9025d92e9f78bffe","artifactSha256":"c657056a9d56f3f97714c47dd42f96f88d6cc7ff6b8c92c7f0f117cd882bff25","bytes":166456,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1283230000/native-254355cc24d59491e867d9b2-step","customerPrice":0},{"id":"native-ae2835bf5a26d506b4f0c6a1-zip","name":"1283230000_DWG.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DWG"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/a0292340-ab9b-43e4-ad36-870dc7a30254/original/1283230000_DWG.zip","sourceSha256":"ae2835bf5a26d506b4f0c6a12ff5ba9df33325041570efad54d49feb25c5c4fd","artifactSha256":"ae2835bf5a26d506b4f0c6a12ff5ba9df33325041570efad54d49feb25c5c4fd","bytes":107528,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1283230000/native-ae2835bf5a26d506b4f0c6a1-zip","customerPrice":0},{"id":"native-76cc1c9915c8197daec261e8-zip","name":"1283230000_DXF.zip","format":"ZIP","purpose":"Manufacturer native CAD archive","containedFormats":["DXF"],"downloadFormat":"ZIP","provenance":"manufacturer_source","sourceUrl":"https://assets.dam.weidmueller.com/assets/api/b010034e-9b71-4d2c-acba-5064146afc1b/original/1283230000_DXF.zip","sourceSha256":"76cc1c9915c8197daec261e8da9a5779eee234f4cefb8948d34881ca376ead06","artifactSha256":"76cc1c9915c8197daec261e8da9a5779eee234f4cefb8948d34881ca376ead06","bytes":86322,"archiveMember":null,"revision":null,"access":{"policyVersion":1,"access":"public","reason":"public_original"},"downloadUrl":"/tools/cad-library/download/weidmueller-article-1283230000/native-76cc1c9915c8197daec261e8-zip","customerPrice":0}],"equipmentFacts":[{"label":"Equipment / resource","value":"MOS 24VDC/8-30VDC 2A E — Optocoupler (relay) / Solid-state relay, 24 V DC ±20 %, Varistor, Reverse polarity protection, 8...30 V DC, 2 A, Screw connection"},{"label":"Manufacturer","value":"Weidmüller"},{"label":"Resource type","value":"Product"},{"label":"Part number","value":"1283230000"},{"label":"Manufacturer reference","value":"1283230000"},{"label":"Manufacturer type","value":"MOS 24VDC/8-30VDC 2A E"},{"label":"Available native formats","value":"DWG / DXF / STEP"},{"label":"Listed file formats","value":"DWG, DXF, STEP"},{"label":"Listed files","value":"3"},{"label":"Available previews","value":"2 drawing previews"},{"label":"Recorded revisions","value":"Confirm the revision with the manufacturer"},{"label":"Source checked","value":"2026-11-17"},{"label":"Download access","value":"Website downloads require email registration once. API trial: 50 files / 512 MiB daily; registered free: 1,000 files/month; verified existing paid plan: 10,000 files/month. Exclusive Elora conversions require a free CAD Library account; conversions without an access review are not released. Manufacturer requirements may apply."}],"previewImage":"/tools/cad-library/drawing-preview/weidmueller-article-1283230000/native-ae2835bf5a26d506b4f0c6a1-zip?asset=b24404b8adc4c46577c4e7b09717d98012b12e7187f73da7773293150d31e243","relatedReferences":[{"name":"Protection relay IED","url":"https://eloragrid.ai/objects/ga-protection-relay-ied"},{"name":"Power quality meter","url":"https://eloragrid.ai/objects/ga-power-quality-meter"}],"fileChoiceGuidance":["Start with 1283230000. The files above belong to Weidmüller's MOS 24VDC/8-30VDC 2A E — Optocoupler (relay) / Solid-state relay, 24 V DC ±20 %, Varistor, Reverse polarity protection, 8...30 V DC, 2 A, Screw connection resource; match any model or option suffix in the filename to your selected unit.","Available here: STEP, ZIP. The individual filenames above distinguish the supplied variants."],"plainEnglish":{"title":"What the equipment does","introduction":"A surge protective device limits brief voltage spikes by providing a path for surge current under its designed conditions.","example":"At a substation cable interface, it can help limit a transient voltage reaching connected equipment.","drawings":"Use an outline or mounting drawing to plan where the equipment fits and where it attaches. Use a connection drawing to trace its electrical interfaces. A 3D model helps coordinate space; check the manufacturer's installation requirements separately.","terms":[{"name":"CAD","meaning":"Computer-aided design files used to prepare drawings and models."},{"name":"Revision","meaning":"The recorded version of a drawing or model."}],"diagram":"flow","steps":["Brief voltage spike","Surge protection responds","Voltage is limited"],"caption":"A simplified explanation of how this item works. It does not show terminal wiring or an operating procedure.","sources":[{"label":"Weidmüller official source","url":"https://eshop.weidmueller.com.cn/en/mos-24vdc8-30vdc-2a-e/p/1283230000/downloads#engineering-support"}],"profileId":"surge"},"canonicalUrl":"https://eloragrid.ai/tools/cad-library/equipment/weidmueller-article-1283230000"}